Q: TPA2034D1 Thermal shutdown data

Would you let us know if there is any measurement result about TPA2034D1 thermal shutdown behavior for the following condition:

 - full power output to 4ohm

- SE output

- PVDD = 5V
 
Probably it will be needed to use thermal stream to rise the Ambient temperature and surface temperature to see thermal shutdown. Then please let me know surface and ambient temperature when shutdown will be occurred.
Any confirmation will be highly appreciated.
 
A: RE: TPA2034D1 Thermal shutdown data
Under the conditions stated, thermal shutdown occured at 132C surface temperature and 100C ambient temperature at output power 2.65W on 4 ohm load.

Let me know if you need additional tests to be performed, if not please mark answer as verified.