Hello,
The TPS7A76150 spec is not clear on the value of the internal pull down on EN.
Thanks in advance.
Scott
This thread was moved from the linear regulators forum to the automotive forum. Please kindly provide the specs above.
Regards,
Darwin
Hi Scott,
Sorry for the late reply, the typical value of the internal pull down on EN is 500Kohm.
Best regards
David
Thanks. The specs states an external pullup required on nRST. Is there an internal pullup?
There is not an internal pull-up. Thanks!