DDC112 TEST Mode communication

This question is answered
Benjamin Kuch
Posted by Benjamin Kuch
on Apr 25 2012 08:49 AM
Prodigy60 points

Hi everyone,

I just get into the DDC112. A first prototype is built and I'm currently implementing the communication.

This is what I did so far:

  • Within the initialization TEST is set to HIGH and RANGE0-2 is set to 111 (Cf = 87.5pF)
  • CLK is connectect to the 7.372800MHz microcontroller clock
  • A timer toggles the CONV pin every 1ms
  • As soon as DVALID goes LOW, an external interrupt is triggered
  • Within this external interrupt DXMIT is set to LOW
  • Afterwards DOUT is read and the DCLK is manually toggled two times
  • This is done 40 times
  • Later DXMIT is set to HIGH again

Unfortunatly, if I convert the 40bit string into two 20bit integer values, they don't look like the suggested output.

Thanks...

Benjamin Kuch

Seabear Diving Technology

DDC112
Report Abuse
  • Reply
You have posted to a forum that requires a moderator to approve posts before they are publicly available.
All Replies
  • Tom Hendrick
    Posted by Tom Hendrick
    on Apr 25 2012 18:19 PM
    Guru86220 points

    Hi Benjamin,

    The DDC112 is actually supported in the Medical/High Reliability forum so I'll move your post for you.  In the meantime, can you describe your DCLK a bit more?  It sounds like you are doing a sort of bit-bang routine, what is the actual period of the clock?  Any chance you can send us screen captures of the interface?

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Benjamin Kuch
    Posted by Benjamin Kuch
    on Apr 26 2012 04:58 AM
    Prodigy60 points

    Hi Tom,

    I don't use any oscillator for DCLK. I simply toggle an output PIN of the microcontroller, connected to DCLK.

    On the oscilloscope I see the data on DOUT. The timings seem to fit as well.

    What do you mean by 'screen capture of the interface' - the measured data output?

    Cheers

    Ben

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Bob Benjamin
    Posted by Bob Benjamin
    on Apr 26 2012 11:54 AM
    Mastermind34195 points

    Benjamin,

    What we need to see is the timing of all the clocks and data as shown on an oscilloscope.  You did not say the timing of the DCLK period.  You must make sure that you are not shifting out data when CONV toggles.  Also, all data must be shifted out before the next falling edge of DVALID.  The best procedure is to make sure all 40 bits of data are shifted out between the falling edge of DVALID and the next toggle of CONV.

    Best regards,

    Bob B

    DDC112
    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Benjamin Kuch
    Posted by Benjamin Kuch
    on Apr 27 2012 08:24 AM
    Prodigy60 points

    Hi Bob,

    on the pictue you see the timings of DCLK - DOUT (yellow) DCLK (cyan).The clock periods are not continous. I only toggle a Pin.

    I shift out the data as soon as DVALID goes low (external interrupt), so it is done before the next falling edge of DVALID.

    Regards

    Benjamin

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Bob Benjamin
    Posted by Bob Benjamin
    on Apr 27 2012 10:24 AM
    Verified Answer
    Verified by Bob Benjamin
    Mastermind34195 points

    Benjamin,

    It is quite essential to have a clean clock.  It appears that there is some glitching or extra clocks around 8 and 18.  I also see another clock pulse at the end of the screen shot.  Is that the next sequence?  Does DCLK complete not only before the next DVALID but also before the next CONV?  Do you have more than a two channel scope?  It would be good to also see DVALID, DXMIT and CONV signals as well?  I know that is five, but maybe a couple different shots showing the relationship of timing even with 2 channels would be helpful.

    Initially I would focus on why you are having those extra pulses.

    Best regards,

    Bob B

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Benjamin Kuch
    Posted by Benjamin Kuch
    on May 03 2012 02:40 AM
    Prodigy60 points

    Thanks Bob!

    Finally I managed to get it to work properly!!! Currently I still have some problems with the voltage supply, but it should be solvable.

    But I have another question... How does the digital filter inside the DDC112 work. I have not found any information about it in the datasheet.

    Regards

    Benjamin

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Bob Benjamin
    Posted by Bob Benjamin
    on May 04 2012 07:40 AM
    Mastermind34195 points

    Benjamin,

    Glad to here you are making progress.  I'm not sure which type of digital filter is used for the DDC112. Basically the delta-sigma modulator oversamples the input and by doing so moves the quantization noise into the higher frequencies and the digital filter then removes the higher frequency component.  Variations of the filter can also remove various other frequencies depending on the design.  Unfortunately, I don't currently have access to any further information regarding the filter.

    Best regards,

    Bob B

    DDC112
    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Benjamin Kuch
    Posted by Benjamin Kuch
    on May 15 2012 07:29 AM
    Prodigy60 points

    Hi Bob,

    thanks for your support!

    I have another question... Currently my data transfer (reading the DOUT PIN) is quite slow. I do everything manually (set clock, start data transfer, read DOUT, ...).

    Is it also possible to use SPI for the communication?

    Regards

    Benjamin

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Bob Benjamin
    Posted by Bob Benjamin
    on May 18 2012 19:51 PM
    Mastermind34195 points

    Benjamin,

    You should be able to use the SPI peripheral.  You just need to make sure you maintain the timing requirements for the DDC112.

    Best regards,

    Bob B

    DDC112
    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Benjamin Kuch
    Posted by Benjamin Kuch
    on Jul 11 2012 10:34 AM
    Prodigy60 points

    I'm using the DDC112 now for a while and I thought it works fine. Now I recognized, that my maximum output value of IN1/IN2 is 4194303 (2^22) instead of  1048575 (2^20)???

    To get the data (after DVALID toggles) I run the following code (I only grap the data of IN2):

    uint32_t readADC(void) {

        uint32_t bitValue = 0;
        uint32_t result = 0;
        uint8_t x = 0;

        // start data transmission -> DXMIT to low
        PORTC.OUTCLR = PIN4_bm;

        // read databits
        for(uint8_t j=0; j<20; j++)  {

            x = 19 - j;
            bitValue = PORTC.IN & PIN2_bm;
            bitValue <<= x;
            result |= bitValue;
            
            // generate DCLK
            PORTC.OUTSET = PIN6_bm;
            PORTC.OUTCLR = PIN6_bm;
        }    

        // stop data transmission -> DXMIT to high
        PORTC.OUTSET = PIN4_bm;

        return result;
    }

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Bob Benjamin
    Posted by Bob Benjamin
    on Jul 11 2012 11:42 AM
    Mastermind34195 points

    Benjamin,

    I really don't see anything obviously wrong here.  Have you verified your data with a scope reading?  As you are only looping through 20 bits, you should not be getting a larger value.  You may have an issue passing the variable within your program.

    Best regards,

    Bob B

    DDC112
    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use