Hi sir,

I have a doubt,our TM4C129ENCPDT controller can be able to route track width of 0.15mm, when i study the system guidelines pdf  they mentioned about the differential pair routing details, then how could i do the differential pair routing of width of 12mils(0.3048) and gap 24mils(0.6096)

  • Are you trying to layout the routing for a differential pair of analog signals for the A to D converter, or a differential transmission line? Can you specify which signals you are trying to route?

    Best Regards,
    Bob Crosby

  • In reply to Bob Crosby:

    Since I have not heard back from you, I assume you have resolved your issue. If not, please reply to this thread.

    Best Regards,
    Bob Crosby