TI Home » TI E2E Community » Support Forums » Data Converters » Precision Data Converters » Precision Data Converters Forum » ADS1675, EVM, Power
Share
Precision Data Converters
  • Forum
  • Files
  • E2E Wiki
Options
  • Subscribe via RSS
Check out
The Signal blog
  • $core_v2_blog.Current.Name

    Handy Gadgets and Resistor Divider Calculations

    Posted 5 days ago
    by Bruce Trump
    Handy gadgets make our engineering life easier—the little...
  • $core_v2_blog.Current.Name

    Chopper Op Amps—are they really noisy?

    Posted 13 days ago
    by Bruce Trump
    Chopper op amps offer very low offset voltage and dramatically...
  • $core_v2_blog.Current.Name

    Bypass Capacitors… yes, but why?

    Posted 26 days ago
    by Bruce Trump
    Everyone knows that op amps should have power supply bypass capacitors...

Forums

ADS1675, EVM, Power

This question is answered
Terry16065
Posted by Terry16065
on Mar 22 2012 18:48 PM
Expert1215 points
Is there an eval board for the ADS1675?
 
Customer has an ADS1672 board, can they just drop this in (maybe with some mods)?
 
Also, in this application (multiple channels, not real airflow) power is VERY important.  Is it possible to run the ADS1675 at 1672 speeds in order to save power?  Looking for ways to save on active power.  Any tricks?
 
Report Abuse
  • Reply
You have posted to a forum that requires a moderator to approve posts before they are publicly available.
All Replies
  • Tom Hendrick
    Posted by Tom Hendrick
    on Mar 22 2012 20:17 PM
    Verified Answer
    Verified by Terry16065
    Guru86190 points

    Hi Terry,

    There is a board for the ADS1675, you can find details of that here:

    http://www.ti.com/tool/ads1675ref

    Power dissipation is dominated by the size of RBIAS in these parts - the clock speed does have an impact, but you won't see dramatic power reduction running the ADS1675 at slower data rates.  Both the ADS1672 and ADS1675 have power vs. RBIAS curves in their respective datasheets which will give you an idea of the potential delta.  Both devices are pin compatible, but we'd have to do a little investigation as to the ability to put the ADS1675 onto the ADS1672EVM-PDK.

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Terry16065
    Posted by Terry16065
    on Mar 22 2012 21:34 PM
    Expert1215 points

    Thanks Tom, I didn't even think of looking at the reference design because reference usually doesn't mean a board!

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Terry16065
    Posted by Terry16065
    on Apr 10 2012 18:18 PM
    Expert1215 points

    Tom,

    Another question on power:

    -----

    We have a major power consumption issue (ADS1672) that we need to resolve before looking at the ADS1675.  I will assume the same answers apply to ADS1675. 

    Data sheet shows 3 power numbers:

    Power down = 5mW

    TYP power dissipation = 350mW

    Max power dissipation = 370mW

     

    Question – How much does the power vary if there is no conversion in process?  I.e. start is inactive.

    Question – Can you break down the power numbers more so that I know what area of the chip consumes it?  Example – modulator, filters – LVDS interface.

    Question – Any suggestion on power saving?

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Tom Hendrick
    Posted by Tom Hendrick
    on Apr 12 2012 10:58 AM
    Guru86190 points

    Hi Terry,

    I don't have the exact breakdown but the delta in power consumption from 'start' being active to inactive will be minimal - the bulk of the power is consumed by the modulators and bias circuitry.  The LVDS interface is only a minor portion of the overall power consumption.  I'll look through the design documentation and see if I get get you some real numbers.

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Tom Hendrick
    Posted by Tom Hendrick
    on Apr 12 2012 15:54 PM
    Verified Answer
    Verified by Austin Miller
    Guru86190 points

    Hi Terry,

    I confirmed that there is no distinction (power wise) regarding the state of the START pin.  AVdd current is 51mA at 5V, which is the modulator current.  The filter consumption is 22.5mA at 3V, and the LVDS consumes about 10.5mA.  Going into the power down state is the only way to conserve on energy consumption.

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Terry16065
    Posted by Terry16065
    on Apr 12 2012 16:52 PM
    Expert1215 points

    Thanks Tom.

    Terry

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Terry16065
    Posted by Terry16065
    on Apr 27 2012 16:28 PM
    Expert1215 points

    Another question on this:

    I am trying to figure out how much time, at the system level, I need if I enter and exit power down mode. 

    For now, looking at 1672, I see the following in your data sheet:

    --

    When not in use, the ADS1272 can be powered down by taking PDWN pin low. All circuitry shuts down, including the voltage reference. To minimize the digital current during power down, stop the clock signal supplied to the CLK input. Make sure to allow time for the reference to start up after exiting power-down mode.

    After the reference has stabilized, allow for the modulator and digital filter to settle before retrieving data.

    --

    I am trying to calculate the required exit time from Power down. 

    Q1 - What is Time for voltage reference to stabilize?

    Q2 - What is Time for modulator and digital filter to settle before retrieving data?

    I do see settle time data after each data is retrieved depending on the filter configuration.  But I do not see any timing exiting PWR-DWN

     

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Tom Hendrick
    Posted by Tom Hendrick
    on Apr 27 2012 18:26 PM
    Guru86190 points

    Hi Terry,

    Unfortunately I can't give you an absolute answer for Q1 - the reference stabilization is going to be dependent on the external capacitor you have on your board as well as your layout to some extent (parasitic capacitance, etc).   I'll look into Q2 for you and see what I can find out.

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Magid Fazel
    Posted by Magid Fazel
    on May 15 2012 13:33 PM
    Prodigy10 points

    Hi Tom,

    My name is Magid Fazel from Teledyne RDI.  I am the customer who was asking all of these questions from Terry.  Terry suggested to contact you directly. 

    Thanks for the follow-up.  I wait for the response to the second question.  Meanwhile, I am confused about the reference stabilization comments and the capacitors. Is the “reference voltage stabilization” time referring to the time for our board to make sure the voltage reference is stable?  If so, why does it depend on the power down signal going to the ADS device?  Perhaps, you can provide details on your own reference board.  Are you referring to the capacitors C23 and C24 in your reference design? 

    The statement in the data sheet gave me the impression that part of the reference voltage is internal to ADS device.  Please assume that we do NOT turn off the reference voltage or any or the power rails when we go in power down.  Assume that we assert the power down to the ADS device AND turn off the 20MHz to the ADS device ONLY.        

    I am basically trying to put the device into power down state in between accesses.  I need to know how much time I need to allocate to the ADS device going into power down and coming out of power down.  I am obviously controlling the external power, reference voltage, clocks to the ADS device.  All I need to know is how long will the device require.

    Thank you very much

    Magid

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Tom Hendrick
    Posted by Tom Hendrick
    on May 15 2012 21:06 PM
    Guru86190 points

    Hi Magid,

    I'll be in touch with you soon to discuss details.

     

    Regards,

    Tom

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use