Following the instructions in the TI document SLVA424-April 2010 "Importing a SPICE NetList into TINA-TI,
I get the following error message after successfully importing and compiling the AD8675 and ISL28127 op-amps:
The circuit cannot be converted to a macro .
This error was not a problem with the TI OPA551 component.
How do I modify the .cir files to be compatible with this simulator?
Hi Charlie.
I am a modeling engineer with the Analog eLab team.
TINA will easily import TI models of TI devices. Unfortunately there are no guarantees that other vendors' Pspice macros will work in TINA.
The best approach is to get with your TSR, AFA, or FAE to get some help converting the model to a TINA format.
An alternative is to contact the TI product Information Center and ask for help with the model conversion. Contact information is avilable at:http://www-k.ext.ti.com/sc/technical-support/product-information-centers.htm?DCMP=TIHomeTracking&HQS=Other+OT+home_d_contact
Best Regards,
John Miller