Non-Uniform Intensity in Projected Images

This question is not answered
Veronica Marin
Posted by Veronica Marin
on Feb 28 2012 12:49 PM
Prodigy110 points

Hello TI tech support,

When I use a white image, i.e. all the pixels are “ON”, the captured image reveals a non-uniform behavior of the light coming out from the LightCommander. I have done several tests and consistently got the same behaviour for different frame rates. The projected image is not uniformly illuminated since it has a brightest area and from there the intensity level decreases in a "wavy" fashion. I expected to get approximately the same intensity level on all the pixels.
 
Is this the expected behaviour? Is there anything I can change/adjust to correct this non-uniformity?

Also, is there a specific spatial pattern for the non-uniformity of the projected intensity that is consistent across projector units, or is it totally random? I ask this last question to get a sense if the non-uniformity is due to hardware (panel, optics) limitations, or is just the expected "random" variation during manufacturing.
 
Thanks,
Veronica
DLP LightCommander lightcommander light uniformity Light commander LC
Report Abuse
  • Reply
You have posted to a forum that requires a moderator to approve posts before they are publicly available.
All Replies
  • Sanjeev
    Posted by Sanjeev
    on Feb 29 2012 08:07 AM
    Expert5745 points

    Hi Veronica,

    If you have captured and attached the picture in the discription it would have been easy to understand.

    Couple of things you need to try -

    1) Check the aperture settings on the projection lense. Refer to user guide on adjusting the projection lense.

    2) We found that the curved mirror setup in the optical module is mis aligned while shipment. There are two curved mirrors in the optical path which will bend the light from LEDs to the DMD mirror array. The mis-alignment could result in showing pinkish color tinge in the displayed white images. If this is what you are seeing then you can try contacting distrubutor where you purchased the kit. If not then i will send you the instructions.

    Regards,

    Sanjeev

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Veronica Marin
    Posted by Veronica Marin
    on Mar 02 2012 15:47 PM
    Prodigy110 points

    Hi Sanjeev,

    Here is one image showing the behavior described before. For this image, the projector was placed perpendicular to the projection plane.

    Regarding the options,

    1) The aperture lens we are using is 2.8 as suggested on page 11 of the user guide.

    2) I think the curved mirror is OK since it is not showing a pinkish image. We had this problem with the first unit and it was replaced by Logic.

    Regards,

    Veronica

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Veronica Marin
    Posted by Veronica Marin
    on Mar 02 2012 17:39 PM
    Prodigy110 points

    Sorry... I forgot to attach the image.

    Thanks,

    Veronica

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Sanjeev
    Posted by Sanjeev
    on Mar 03 2012 22:50 PM
    Expert5745 points

    Hi Veronica,

    It looks like the light beam is out of focus when falling on the DMD. Two things could be possible suspects,  a) problem with one of the element in the optical path is misaligned b) it could be DMD seating on the adapter board is moved. Let me check with optical expert here to find what optical element has to be adjusted.

    Regards,

    Sanjeev

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Sanjeev
    Posted by Sanjeev
    on Mar 05 2012 22:22 PM
    Expert5745 points

    Hi Veronica,

    I got some more details for you.

    Even if the optics and DMD is aligned perfectly there will be 'some' roll-off. A little tweaking in the DMD position can move the brightes spot to the center but will not 100% get rid of the vignetting.

    Couple of suggestion to mitigate this effect.

    1) Reduce the LED current intensity a bit

    2) Adjust the camera iris and/or projection lense until the roll-off effect is diminished.

    Let me know if this is helpful to you.

    Regards,

    Sanjeev

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Veronica Marin
    Posted by Veronica Marin
    on Mar 12 2012 11:29 AM
    Prodigy110 points

    Hi Sanjeev,

    I made what you suggested and the problem is still there. The DMD array is smaller compare to the sensor for which the lens was built for. Then, I wonder why are we going to have vignetting? and how is this related to the deviation of the brightest area? If we need to project the same intensity on different pixels, how are we going to do this if the intensity levels have a spatial pattern?

    Regards,

    Veronica

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Sanjeev
    Posted by Sanjeev
    on Mar 14 2012 05:23 AM
    Expert5745 points

    Hi Veronica,

    I received your further query. I will check  with our optical expert and ask about any recommendations if they have.

    Regards,

    Sanjeev

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
  • Fizix
    Posted by Fizix
    on Mar 14 2012 14:18 PM
    Expert5200 points

    Hello Veronica,

    You are correct that the projection lens is designed for a sensor (DX) that is larger than the DMD array.  There is no vignetting from the lens in the final image. 

    The issue is not on the projection side, but on the illumination side.  The illumination is approximately shaped like the DMD with some overfill, but there is still 'some' rolloff (you could call this "illumination vignetting"). 

    Regarding the image that you attached in your message above: 

    It is difficult to tell from the image alone what the actual difference in measured intensity is from the center to the edge of your image.  If the illumination shows gross rolloff then one of the optical elements between the illumination module and the DMD are out of alignment.  However, it is very difficlut to elimate all rolloff.   

    The effect of rolloff and how you can mitigate the effect depends greatly on the particluar application that you are targeting.

     

    Fizix 

    Report Abuse
    • Reply
    You have posted to a forum that requires a moderator to approve posts before they are publicly available.
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use