• Join
  • Sign In with my.TI Login
Texas Instruments
  • Products
  • Applications
  • Tools & Software
  • Support & Community
  • Sample & Buy
  • About TI
Sample & Purchase Cart Sample & Purchase Cart
  • Search
  • Advanced
TI E2E™ Community
  • Support Forums
  • Blogs
  • Groups
  • Videos
  • 简体中文
  • More ...
TI Home » TI E2E Community » Support Forums » Digital Signal Processors (DSP) » C6000 Multicore DSP » All Tags » 6474 SRIO AIF
Share
C6000 Multicore DSP
  • Forums
  • Announcements

Browse by Tags

C6000 Multicore DSP

Welcome to the C6000 Multicore DSP Section of the TI E2E Support Community. Ask questions, share knowledge, explore ideas, and help solve problems with fellow engineers. To post a question, click on the forum tab then "New Post".

Tags
You have subscribed to this tag. To view or manage your tag subscriptions, click here.   Close
You have unsubscribed from this tag. To view or manage your tag subscriptions, click here.   Close
You are currently viewing:
6474 SRIO AIF
  • 6474
  • 6474 SRIO
  • AIF
  • TMS320C6474
Related Posts
  • Forum Post: Direct I/O Library and Using the TMS320C6474 Antenna Interface (AIF) for Inter-DSP Communication

    Wang Nan15088 Wang Nan15088
    Hi, I have some problems and I need help please. these days , I found therr are new Application Notes on TMS320C6474: I found there are 2 new Lib for us,Direct I/O Library and Using the TMS320C6474 Antenna Interface (AIF) for Inter-DSP Communication On the https://gforge.ti.com, I found the two project...
    on Sep 16, 2009
  • Forum Post: Re: C6474 SYS Clock vs FSYNC Clock

    Tom Johnson16214 Tom Johnson16214
    There is no requirement for maximum skew between these clock sources. The only requirement is for frequency coherency. Either one of the clocking solutions proposed will be acceptable. Skew matching is not needed between the SYSCLK and FSYNCCK signals.
    on Feb 18, 2011
  • Forum Post: RE: Two C6474 EVMs communicate with each other through AIF?

    Kaiqi Yang Kaiqi Yang
    Is there anyone know?
    on Jul 25, 2012
  • Forum Post: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    In AIF user's guide, it says:"Both OBSAI and CPRI support inter-TMS320C6474 communication. Control messages for OBSAI and vendor-specific control words for CPRI provide the capability for non-IQ data transfer. " Does this mean the data between DSPs can not be transfered in IQ format?
    on Jul 25, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    Thanks for your answer. And could I understand like this: IQ data can be used for inter DSP communication but we usually do not use them to do so?
    on Jul 26, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    I found the example discribed in sprab58 are implemented on TCI6488, could the example work out on TMS320C6474?
    on Jul 26, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    Hi, I have tried the example on C6474, and it seems works well, but I'm wondering why link 3 and link 4 can not get any good frame?
    on Jul 30, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    Sorry, and the project is with the application report "TCI648x Antenna Interface Programming", and I notice that you are one of the authors.
    on Jul 31, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    Sorry to bother you again, in my project, DSP1 transfers data to DSP2 and DSP2 do not redirect these data, so my question is how can I change the code based on sprab58?
    on Aug 2, 2012
  • Forum Post: AIF for inter-DSP communication

    Kaiqi Yang Kaiqi Yang
    Hi, I have tried the project from http://www.ti.com/general/docs/litabsmultiplefilelist.tsp?literatureNumber=sprab58 on C6474, and it works well. In my project, I want DSP1 transfer data to DSP2, but DSP2 do not redirect those data back to DSP1, how can I change the code in the example project?
    on Aug 2, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    What I want to do is implement inter-DSP communication without data redirection, that means what DSP1 need to do is to transfer data to DSP2 through AIF and what DSP2 need to do is to receive data from DSP1 and check its correction. So what I want to do seems easier than your project in prab58, and I...
    on Aug 3, 2012
  • Forum Post: RE: problem about aif on C6474

    Kaiqi Yang Kaiqi Yang
    http://focus.ti.com/general/docs/litabsmultiplefilelist.tsp?literatureNumber=sprab58, I notice that you are one of these authors, and I ues TMS320C6474
    on Aug 4, 2012
  • Forum Post: IACLIB without DSP/BIOS

    Kaiqi Yang Kaiqi Yang
    Is there anybody has IACLIB for interDSP communication without DSP/BIOS?
    on Aug 6, 2012
  • Forum Post: Problem about AIF

    Kaiqi Yang Kaiqi Yang
    Hi, I'm a beginner of AIF, and I download a example project from http://www.ti.com/general/docs/litabsmultiplefilelist.tsp?literatureNumber= sprab58. The project works well on TMS320C6474, and I have several questions: 1.In the external redirection test, it seems that DSP1 and DSP2 are transfering...
    on Aug 14, 2012
  • Forum Post: RE: AIF on C6474

    Kaiqi Yang Kaiqi Yang
    RandyP: Thanks for your answer! The device number is C6474 and I made a spelling mistake in my former post. And I think my unclear expression makes you misunderstand what I meant. Firstly, as a one-time transmission process, the data transmission from DSP2 to DSP1 is successful which I've done...
    on Sep 2, 2012
  • Forum Post: RE: AIF on C6474

    Kaiqi Yang Kaiqi Yang
    RandyP: By the way, in section 5.2 of "TMS320C6474 DSP Antenna Interface User's Guide", it refers line rates and data rates of SERDES, what the difference between them. And the data rates lists in the table is theoretical or practical?
    on Sep 2, 2012
  • Forum Post: RE: AIF on C6474

    Kaiqi Yang Kaiqi Yang
    RandyP: No, I'm not using IACLIB, and I have downloaded the example with IACLIB, but it use OBSAI RP3(CPRI is required in my project). And I will appreciate it If you could offer me the IACLIB example in CPRI version. Now I am pretty sure that the timer couldn't be normally triggered in the...
    on Sep 3, 2012
  • Forum Post: RE: AIF on C6474

    Kaiqi Yang Kaiqi Yang
    RandyP: Thanks a lot! I will see what I can do to solve those timer issues and I'm also looking forward for more advice. Regards, Kaiqi Yang
    on Sep 4, 2012
  • Forum Post: Problem about FSYNC restarting on C6474

    Kaiqi Yang Kaiqi Yang
    Hi, I am doing a project which fulfill two successive transfer between DSP1 and DSP2. After the first transfer is done, the FSYNC module should be reset for the next transfer, but I'm not sure if the following code is right or not: int i; if(FsyncRegs->CTL2) { /*Halt the timer by programming...
    on Sep 4, 2012
  • Forum Post: Synchronization problem of AIF on C6474

    Kaiqi Yang Kaiqi Yang
    Hi, I am doing inter-DSP communication through AIF on C6474. In my project, the FSync module of DSP1 and DSP2 are driven by same differential clock source on the board which is timer0 of DSP1. Here comes the question, if I want to implement inter-DSP communication between two different EVM boards, how...
    on Sep 5, 2012
  • Forum Post: RE: AIF on C6474

    Kaiqi Yang Kaiqi Yang
    RandyP, Thanks for your help and the problem is solved perfectly. But I have another question to ask you. In my project, the FSync module of DSP1 and DSP2 are driven by same differential clock source on the board which is timer0 of DSP1. Here comes the question, if I want to implement inter-DSP communication...
    on Sep 6, 2012
  • Forum Post: RE: Wrong data in AIF transfer

    Kaiqi Yang Kaiqi Yang
    The program is tested between DSP1 on TMS320C6474 EVM1 and DSP2 on TMS320C6474 EVM2 with SMA connecting, and the used link is, of course, link 0. Here is my code for receiver(once it received enough frames and the last data is correct, it stops): if(0x000006FF==antennaBuffer[0].uiInboundAntennaPingBuf...
    on Sep 26, 2012
  • Forum Post: Problem about AIF in CPRI protocol

    Kaiqi Yang Kaiqi Yang
    When I'm using AIF to transfer data between two DSPs, how could the receiver DSP supposed to know that the transfering process is done? Is there any control words in frame to notice the reciver when to stop receiving data?
    on Sep 26, 2012
  • Forum Post: RE: Wrong data in AIF transfer

    Kaiqi Yang Kaiqi Yang
    Thanks for your answer! Yes, I use wire to connect JP8 on two TMS320C6474, so timer0 of DSP1 on EVM1 could trigger fsync on EVM2. Is there any possible solution of this problem?
    on Sep 26, 2012
  • Forum Post: RE: Wrong data in AIF transfer

    Kaiqi Yang Kaiqi Yang
    Thanks for your answer and I'll see what I can do.
    on Sep 26, 2012
12
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use