i think the opp 160% is 450MHz , but we can find that dm8168bcye2 hdvicp2 can work on 600MHz frequency , can dm8148 hdvicp2 work on 600MHz frequency ?
Hi Yu,
The DM8148 HDVICP2 can only go up to 450 MHz with OPP166 according to the Table 7-4. Device Operating Points (OPPs) in our Data Manual. If you need 600 MHz frequency, please go with our DM8168.
BR,