TIC12400: paralleling inputs to get more wetting current

Part Number: TIC12400

HI team, Could I connect 2 inputs each sourcing 15mA to give 30mA capability?

  • Hello Ajayt,

    This would only work in the continuous mode. In the polling mode the device will turn on the current sources individually.

    Regards,
    Andrew
  • In reply to Andrew_Mason:

    Hi as a follow up question on teh ADC

    I have a technical question with regards to the TIC12400…. You mentioned before that the ADC measures voltages from 0-6V (1024 max codes), but in the data sheet it mentions a VS Ratio bit that can be applied to increase the voltage measurement to 30Vdc – is this only for measuring the VS supply or can it be applied to the input monitor pins as well?

     

  • In reply to ajayt:

    Hello Ajayt,

    Yes this is correct, the scaling is only for the VS measurement.

    Regards,
    Andrew