I am looking for the actual sensitive area of the TMP006 Infrared Thermopile Sensor. I have looked at all the data sheets offered on TI's website but have not come across the dimensions of the actual sensitive area of the element. Any help would be apprectiated.
Hello Daniel,
The active area of the integrated thermopile sensor is 330um x 330um. You can see the sensor in the center of the die in the image below.
Best regards,
Ian WilliamsLinear Applications EngineerPrecision Analog and Sensing Products
Thank you!
You're welcome!
Regards,
Ian Williams