• Join
  • Sign In with my.TI Login
Texas Instruments
  • Products
  • Applications
  • Tools & Software
  • Support & Community
  • Sample & Buy
  • About TI
Sample & Purchase Cart Sample & Purchase Cart
  • Search
  • Advanced
TI E2E™ Community
  • Support Forums
  • Blogs
  • Groups
  • Videos
  • 简体中文
  • More ...
TI Home » TI E2E Community » Support Forums » Other Analog & Touch » Temperature Sensors » All Tags » TMP006
Share
Temperature Sensors
  • Forum
  • Files
  • E2E Wiki

Browse by Tags

Temperature Sensors

Welcome to the Temperature Sensors Section of the TI E2E Support Community. Ask questions, share knowledge, explore ideas, and help solve problems with fellow engineers. To post a question, click on the forum tab then "New Post".

Tags
You have subscribed to this tag. To view or manage your tag subscriptions, click here.   Close
You have unsubscribed from this tag. To view or manage your tag subscriptions, click here.   Close
You are currently viewing:
TMP006
  • accuracy
  • body temperature
  • calibration
  • code
  • communication timing
  • emissivity
  • How to monitor Temperature
  • human body temperature measurement
  • I2C
  • I2C bus
  • IR
  • IR sensor
  • lens
  • remote temperature
  • sensor
  • Temp Sensor
  • temperature
  • temperature sensor
  • Temperature Sensor Device
  • Temperature sensors
  • thermistor
  • TMP
  • TMP006 datasheet
  • tmp006evm
  • wavelength
Related Posts
  • Forum Post: Re: TMP006 Field of View and Sensitivity

    Neil Albaugh Neil Albaugh
    Scott; A narrow field of view can be obtained by placing a lens in front of the active area of a sensor. In light of the wavelength responsivity of this device (4um to 8um-- this information SHOULD HAVE BEEN PUT IN THE DATA SHEET!) a lens with a material that is transparent in this range will be required...
    on Jun 17, 2011
  • Forum Post: Re: Eight TMP006 on a signle bus

    Ian Williams Ian Williams
    Hello Tomoaki, I apologize - Table 1 in the TMP006 data sheet which shows the address combinations is incorrect. We are in the process of revising the data sheet, and the new version should be ready by the end of this month. The table below shows the proper connections for all 8 address combinations...
    on Jun 23, 2011
  • Forum Post: Re: Eight TMP006 on a signle bus

    Tomoaki Kobayashi Tomoaki Kobayashi
    Hi Ian, Thanks! So it means that we can make the connections as below? Regards, Tomoaki Kobayashi
    on Jun 24, 2011
  • Forum Post: Re: TMP006EVM / SM-USB-DIG USB protocol documentation for Linux driver?

    Joe Desbonnet Joe Desbonnet
    Thanks -- that was very helpful. The magic is in usb.c (GenCommand() and I2C_Write() functions in particular) and I can see how the protocol works now. I've written some C code using the libusb-1.0 library which sends the TMP006 register queries and I get a response that is tantalizingly close...
    on Jun 24, 2011
  • Forum Post: Re: TMP006 and Cloud Detection

    Neil Albaugh Neil Albaugh
    Johnny; I think the TMP006 would work nicely to sense the presence of cloud cover re cold sky. A Fresnel lens should give you a fairly narrow field of view as well as some optical gain. The IR bandpass of the TMP006 and some plastic lenses/filters was discussed recently in another posting about the...
    on Jun 24, 2011
  • Forum Post: Re: TMP006EVM / SM-USB-DIG USB protocol documentation for Linux driver?

    Joe Desbonnet Joe Desbonnet
    Another clue. Here I am querying the TMP006 0xFE register (manufacturer ID, value 0x5449) and looking at the SDA/SCL lines on H1 with a logic analyzer. Something is going wrong after reading the first byte of data (0x54). But the SDA/SCL trace generated by the Windows software seems identical up to that...
    on Jun 24, 2011
  • Forum Post: Re: TMP006 missing source files

    Ian Williams Ian Williams
    Hello Phil, I have attached the missing files you need. Our apologies for the inconvenience - we'll update the source code on the EVM product folder so this doesn't happen again. Best regards, Ian Williams Linear Applications Engineer High Performance Linear
    on Jul 5, 2011
  • Forum Post: Multiple TMP006EVMs on One Computer

    Brent Gordon Brent Gordon
    Is it possible to use multiple TMP006EVMs on one computer simultaneously? I need to do simultaneous non-contact temperature measurements. I've already changed the address on one of my TMP006 sensor boards, but the evaluation software only recognizes whichever EVM was last plugged in.
    on Jul 7, 2011
  • Forum Post: Re: Multiple TMP006EVMs on One Computer

    Ian Williams Ian Williams
    Hello Brent, It is possible to use multiple TMP006EVMs on one computer, however you would not be able to take truly simultaneous measurements as you'd have to switch between each device in the EVM software. However, since temperature is typically a slowly-changing value I think this implementation...
    on Jul 9, 2011
  • Forum Post: Re: Multiple TMP006EVMs on One Computer

    Brent Gordon Brent Gordon
    Hello Ian, Thanks for the response. I thought daisy-chaining the sensors might be the solution. I did try changing the address in the software with two SM-USB-DIGs connected, but it did not work. Only the most recently connected SM-USB-DIG was recognized. I looked through the data sheet on the...
    on Jul 9, 2011
  • Forum Post: Re: TMP006 and CCS compiler

    Ian Williams Ian Williams
    Hello Matheus, Thank you for your interest in the TMP006. I know that one of our contractors has converted some TMP006 demo board code from IAR to CCS, so let me track that down to share with you. Side note: Nice PC! Have you experimented with your overclock to see how far your hex-core Phenom...
    on Jul 11, 2011
  • Forum Post: Re: TMP006 for Human Temperature Measurements

    Neil Albaugh Neil Albaugh
    Jan; Search this forum for "TMP006"; this question was answered in some detail in another series of posts.
    on Jul 29, 2011
  • Forum Post: Re: TMP006 field of view

    Ian Williams Ian Williams
    Hello Marcello, Yes, the TMP006 can be used to measure the temperature of small ICs at a close distance, but keep in mind that the optimal distance of the TMP006 from the object to be measured is d < (r/2) where r is the radius of the object. In the case of a SOT-23, this distance would be quite...
    on Aug 4, 2011
  • Forum Post: TMP 006 Noise Reduction Modes

    Alex Behnaz Alex Behnaz
    Hello All, I recently purchased a TMP 006 evaluation module, tested it, and have been reading up on these forums & the datasheet. The end application is external body temperature measurement, so extremely low noise is critical. Some of my test results are shown below. Figure 1: The response...
    on Aug 9, 2011
  • Forum Post: Re: TMP 006 Noise Reduction Modes

    Ian Williams Ian Williams
    Hello Alex, I'll first answer your three questions and then offer some other recommendations. 1) On the evaluation kit, how is the filtering done? I assume that the TMP 006 simply takes multiple readings, and the software then does an average. Actually, the averaging is performed inside...
    on Aug 9, 2011
  • Forum Post: help for IC /..!!!

    brijesh patel brijesh patel
    i require the temperature ic with DIP package as it can be useful in breadboard interface...!! so pls ..any 1 can help me to find it in TI..!!!
    on Aug 31, 2011
  • Forum Post: Re: Airflow??

    Neil Albaugh Neil Albaugh
    Benedict; The reason that your readings are consistently low may be due to the low emissivity of the object's surface that you are measuring. Black surfaces have a higher emissivity than white or shiny surfaces-- but this is tricky because we are talking about emissivity in the infrared portion...
    on Sep 22, 2011
  • Forum Post: Re: Airflow??

    Benedict Hartmann Benedict Hartmann
    Thanks for this quick answer. I already painted the surface with a black enamel coating. So the surface is already prepared. The emission coefficient is around 0.85-0.9. What do you mean with our low readings? Is in your opinion the Sensor Voltage too low? Does the sensor have problems with airflow...
    on Sep 23, 2011
  • Forum Post: Re: TMP006 wavelength range

    Dmitry Vasilenko - Arrow Dmitry Vasilenko - Arrow
    Colin, my customer asks to show a spectral absorbtion characteristics of TMP006. Can I show your answer with transmission figure as an answer to their question?
    on Sep 23, 2011
  • Forum Post: Re: TMP 006 Noise Reduction Modes

    Neil Albaugh Neil Albaugh
    Ian; These questions posted about measuring skin temperature are so numerous--together with other moderate-temperature thermometry questions-- that it is clear that the decision to use a cover that cuts off the longer wavelength response of this detector needs rethinking. Marketing should have thought...
    on Sep 23, 2011
  • Forum Post: Re: TMP006 wavelength range

    Neil Albaugh Neil Albaugh
    Collin; Can't a coating be sputtered on to the surface to make it "black" in the IR? This would extend the IR response to a longer wavelength and increase the sensitivity in human-body temperature measurements, etc. I was wrong about thinking the TMP006 spectral response was limited...
    on Sep 23, 2011
  • Forum Post: Re: Airflow??

    Benedict Hartmann Benedict Hartmann
    Thank you really much for this answer. I will test the new software and give you a feedback
    on Sep 26, 2011
  • Forum Post: Re: TMP006 suitable for higher temperature ranges?

    Ian Williams Ian Williams
    Hello Clay, The main concern is that you don't saturate the TMP006's IR sensor in order to maintain a usable sensor voltage reading, so an optical filter or attenuator would be necessary for an application such as the one you describe. Of course, the TMP006 itself can not be operated at temperatures...
    on Oct 11, 2011
  • Forum Post: Re: TMP006 suitable for higher temperature ranges?

    Neil Albaugh Neil Albaugh
    Clay; What you've described is an optical attenuator, AKA an "ND filter". Neutral density filters are wide-spectrum attenuators; they are specified as ND 1.0, ND 2.0, etc. The numerical figure represents the attenuation in tens of dB--- 1.0 is 10dB (1/10), 2.0 is 20 dB (1/100), 3.0 is...
    on Oct 11, 2011
  • Forum Post: TMP006 - best housing materials

    Mark Wagner Mark Wagner
    What materials/thicknesses are recommended for the TMP006 to sit behind (that is, the device housing) in order to maintain greatest accuracy?
    on Oct 15, 2011
1234
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use