Hello,
where can I find detailed graphics like charge current with bq78pl116. For example
http://www.ti.com/lit/ds/slus629a/slus629a.pdf
page 27, but for bq78pl116.
Thanks
Philipp,
I have not seen this graph published for the PL116, but the operation at power-up is fairly simple.. The device remains in reset until the cell voltage reaches approximately 2.9V. VLDO1/2 are low, PRE, CHG and DSG are low and the pack will charge at the pre-charge current. After the cell voltage reaches 2.9V, the regulators, PRE, CHG and DSG turn on and the pack can charge at the full charge current.
RegardsTom
Thanks for your answer.
If you find some graphics for the PL116, I'm still interested.
regards