• Join
  • Sign In with my.TI Login
Texas Instruments
  • Products
  • Applications
  • Tools & Software
  • Support & Community
  • Sample & Buy
  • About TI
Sample & Purchase Cart Sample & Purchase Cart
  • Search
  • Advanced
TI E2E™ Community
  • Support Forums
  • Blogs
  • Groups
  • Videos
  • 简体中文
  • More ...
TI Home » TI E2E Community » Support Forums » Power Management » Battery Management » Battery Management - Gas Gauge Forum » All Tags » "BQ78pl114"
Share
Battery Management
  • Forums
  • Announcements
  • Files
  • E2E Wiki

Browse by Tags

Battery Management

Welcome to the Battery Management Section of the TI E2E Support Community. Ask questions, share knowledge, explore ideas, and help solve problems with fellow engineers. To post a question, click on the forum tab then "New Post".

Sign In to Post
Tags
You have subscribed to this tag. To view or manage your tag subscriptions, click here.   Close
You have unsubscribed from this tag. To view or manage your tag subscriptions, click here.   Close
You are currently viewing:
"BQ78pl114"
  • batter monitory
  • batteries
  • battery
  • battery gauge
  • battery monitor
  • BMS
  • bq2060A
  • BQ20Z45
  • bq20z65
  • bq20z75
  • BQ27200
  • bq27500
  • BQ27510
  • bq27541
  • bq76PL102
  • bq76PL536
  • bq77PL900
  • bq78PL114
  • bq78pl114114
  • bq78PL114EVM
  • bq78PL114S12
  • bq78PL116
  • bq78PL116EVM
  • bqEASY
  • bqWizard
Related Posts
  • Forum Post: Communication between PIC microcontroller - BQ78pl114 and BQ78pl114 Socket for PCB

    Brayts Brayts
    Hello, In the past few months i've being working with bq78pl114 for monitoring a li-ion battery pack, but I have some doubts before I end my application, those are: - Can I use a microcontroller like PIC18F2680 to acess the memory of bq78pl114 while is doing polling data? The ideia is replace the...
    on Nov 21, 2009
  • Forum Post: 12 cell Li-Ion in a 3S-4P

    SB36332 SB36332
    Hi, Just starting to look at this now. We’ve a requirement to build a battery pack for one of our products. The pack is a 12 cell Li –Ion pack, in a 3S-4P configuration , producing a nominal voltage of 11.1 volts with a capacity of 10.4AH by utilizing 2600 mA hour cells. For...
    on Dec 14, 2009
  • Forum Post: Re: Best gas gauge for widely varying loads?

    Jim M15252 Jim M15252
    ! ! CORRECTION ! ! Statement about impedance learning is updated. If NDI calculations occur, then the impedance values of the cells will be updated. 2) Aux files are dependent on cells and pack construction. Impedance values are not learned over time from some nominal value to whatever your specific...
    on Feb 3, 2010
  • Forum Post: Re: bq78pl114 with bq76pl102 industrial calibration without bqwizard

    David S48133 David S48133
    Jim, Any developments re API release and extended SBS command App Note? I searched the TI documentation for the App Note, but no joy. A link would be helpful. Thanks, David
    on Apr 30, 2010
  • Forum Post: Charge and Discharge FETs are turning off, if BQ wizard trying to communicate with evaluation board

    Jigar Patel Jigar Patel
    Evaluation Kit: BQ78PL114 BQ wizard version: 2.5.7 Firmware version: 5000 (CRC: 0x4104) I am trying to track charge and discharge current from BQ wizard. But I am facing strange issue. As soon as I open BQ wizard on PC both charge and discharge FETs are turning Off. And I am not able to observe...
    on May 5, 2010
  • Forum Post: Power Pump Cell balancing of two cells at a same time

    Jigar Patel Jigar Patel
    Can BQ78PL114 and BQ76 balance two cells at a same time? In other words: Does BQ78PL114 and BQ76 transfer energy from two or more cells in single 4.9 usec pump cycle ? For example: If five cells are connected to BQ78PL114 and BQ76. And voltage levels as per below Cell 1 à 3.4 V Cell...
    on May 20, 2010
  • Forum Post: Somke from DIMM board of BQ78PL114 EVM

    Jigar Patel Jigar Patel
    Hello, I am using BQ78PL114 EVM. 18650 cells are in float mode 2 hours (charge current less than 50 mAmps). Than I connected load, to discharge pack ( 400 mAmps, around 5 mins). I had observed that EVM is not balancing during charge and discharge mode. So I enabled System control Register to 0x0001...
    on May 12, 2010
  • Forum Post: Questions for BQ78PL114

    Jigar Patel Jigar Patel
    What will be maximum guaranteed time to turn on charge FET after discharge current detection? Please refer following steps 1) Battery Pack is in cell Over Voltage alarm 2) Charge FET is OFF, Discharge FET is ON 3) User connect load to battery pack (But cell voltage is above recovery voltage...
    on May 27, 2010
  • Forum Post: PR942 8-cell simulator PCB

    Frank Rothoff Frank Rothoff
    Hello team, My costumer asked my the design files of the PR942, however I don't have them. Info: Preparing the PL114 we received for first operation, I read on page 9 of doc SLUU335A that a cell simulator is advised / required. There is mentioning of a prototype design named PR942 that...
    on Jun 11, 2010
  • Forum Post: USB-TO-GPIO interface

    Achmed Giesler Achmed Giesler
    I have received my module, thanks to a supportive TI staff member in the UK. The next step is to try and get it going. I was hoping that the BQwizard software would work, but no luck. I connected up GND, SMBclock and SMBdata, no pullups. But the unit does not want to communicatre with my own BQ78PL114...
    on Dec 22, 2009
  • Forum Post: USB to GPIO interface update required for Pl114

    bing bong bing bong
    Dear TI help, Reading several threads in this forum I am running in the same problems to perform the required update of the USB to GPIO interface for operation with the Pl114. I can not update the USB to GPIO via bqwizard, since the update text file from brqwizard refers to menus that do not ...
    on Jun 16, 2010
  • Forum Post: BQ27510 Production Code

    Nick Moore Nick Moore
    I have written the firmware to program the BQ27510 from the three page flow chart from Going to Production with the bq2750x. However, every time I read register 0x66 to see if the data=0x00 I get the data to equal 0x37. Does anyone have any idea why this might be happening? I'm thinking maybe...
    on Jun 22, 2010
  • Forum Post: Balance current in North and South directions and minimum voltage requirement for power pump to work

    Jigar Patel Jigar Patel
    Hello, I am new to power pump technology. I went through reference manual and application notes, but I am not able to get answer of following questions. Please reply... Is there any workaround for BQ78PL to achieve more than 1 Amp balance current? Is balance current same for North and...
    on May 20, 2010
  • Forum Post: Current measurement of bq78pl114

    Evgen Urlep Evgen Urlep
    Due to mechanical restriction it is not possible to set the current measurement shunt between Ubat- and PACK-, but only between V1 and V2. Seems that then the voltage shift of the current measurement is required. Are there any low power recomendation solutions. Is battery balancing and voltage protection...
    on Oct 28, 2010
  • Forum Post: BQ78PL114 VLAN flag

    Fred P Fred P
    What is the VLAN flag in BQ78PL114?? I cannot find documentation about it anywhere. Thanks
    on Jun 29, 2010
  • Forum Post: BQ78PL114 IGRR failure

    Nigel Wade Nigel Wade
    We have had a number of batteries with IGRR failures running the BQ78PL114 BMS. What is the IGRR and how is it calculated, what is it a ratio of, and how is it different to IGR? Is it a relative measure, or an absolute measure, referenced to something in the .chem or .aux file? What are the...
    on Dec 13, 2010
  • Forum Post: Over Voltage Protection for BQ78PL114/116

    Ran Aloni Ran Aloni
    Hi all I'm currently testing the BQ78PL116. I came across an interesting issue. while any Cell or Pack under voltage status closes the D-FET and opens it when it recovers. while discharging the PACK reaches the qualified discharge voltage and closing D-FET steady until you begin charging...
    on Mar 3, 2011
  • Forum Post: Re: BQ78pl114

    ou gareth ou gareth
    Thanks for your replay. Why has the wrong indicating lamp glittered? I have start fuse but to be unable to stop the twinkle
    on Jun 23, 2011
  • Forum Post: Re: BQ78pl114

    ou gareth ou gareth
    May you tell me , how to improve the temperature unbalance on the bqWizard ,t he temperature already completed the calibration But cell3 & cell4 has the deviate....tks
    on Jul 6, 2011
  • Forum Post: BQ78pl114

    ou gareth ou gareth
    1. How to calibration AD? There are some option to do in the bqWizard software, but I have no ideal setup. At calibrate voltage : It's supply an external mv reference low and high value with the limit between 2700 to 3000 and 4000 to 4500. I try to set low value and no any change, while set high...
    on Jun 2, 2011
  • Forum Post: Re: bq78PL114S8 extended / block SBData commands

    Dirk Kaehler Dirk Kaehler
    Dear Sercan, one reason could be that one of your cells has no connection to the chip or a very strange voltage. In any case try to relearn / initialize. Make sure that no other device is communicating with the TI chip, this is very critical! Best regards, Dirk
    on Jul 29, 2011
  • Forum Post: Re: Using bq78PL114+bq76PL102 on 20 cells LifePo4 battery pack

    Dirk Kaehler Dirk Kaehler
    Hi Ben, the document slua591 is quite helpful, but its not really complete. Programming the extended SMBus Commands with the Pack Configuration Utility allow the user to access many information via dedicated SMBus commands. In our application we need a very tight control on the battery which means...
    on Sep 15, 2011
  • Forum Post: Re: PROBLEM to establish connectivity with BQ78pl114 through SMBus.Please HELP

    Brayts Brayts
    Hi Marcelo, I stop working with bq78pl114 couple years ago, but if I remeber well I solved this problem by connecting the bq78pl114 pin nº31 to the ground. Try to do this and then please tell me if you have successful, maybe I can give you some more tips. Cumps, Brayts
    on Sep 22, 2011
  • Forum Post: bq78PL114

    joe mbwisha joe mbwisha
    Hi There, I'm a student and I want to understand how the temparature sensing is done using the ABV99 and a capacitor?I also would like to know that can a programme be rwiten for this chip or its comes already wiyh one.and where to configure all the commands?What type of cell balancing does the bq78PL114...
    on Oct 30, 2011
  • Forum Post: Bq78PL116EVM

    nicklaus lek nicklaus lek
    Hi, i connected a cell simulator of 4 cells, and supply voltage of 14.8V. when i probe the vss to v1, the voltage is different from v1 to v2 ,v2 to v3, v3 to v4. There is also no connection to the PC Bqwizard. Is the EVM Board Burned?
    on Nov 17, 2011
12
TI E2E™ Community
  • Support Forums
  • Blogs
  • Videos
  • Groups
  • Site Support & Feedback
  • Settings
TI E2E™ Community Groups
  • TI University Program
  • Make the Switch
  • Microcontroller Projects
  • Motor Drive & Control
Other Communities
  • Deyisupport
  • Designsomething.org
  • beagleboard.org
  • TI on Element 14
  • TI on TechXchangeSM
Other Technical & Support Resources
  • WEBENCH® Design Center
  • Product Information Centers
  • Technical Documents
  • TI Design Network
  • TI Technical Articles
  • TI Training

All content and materials on this site are provided "as is". TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with regard to these materials, including but not limited to all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property right. TI and its respective suppliers and providers of content make no representations about the suitability of these materials for any purpose and disclaim all warranties and conditions with respect to these materials. No license, either express or implied, by estoppel or otherwise, is granted by TI. Use of the information on this site may require a license from a third party, or a license from TI.

Content on this site may contain or be subject to specific guidelines or limitations on use. All postings and use of the content on this site are subject to the Terms of Use of the site; third parties using this content agree to abide by any limitations or guidelines and to comply with the Terms of Use of this site. TI, its suppliers and providers of content reserve the right to make corrections, deletions, modifications, enhancements, improvements and other changes to the content and materials, its products, programs and services at any time or to move or discontinue any content, products, programs, or services without notice.

Follow Us Texas Instruments on Facebook Texas Instruments on Twitter Texas Instruments on LinkedIn Texas Instruments on Google+
TI Worldwide | Contact Us | my.TI Login | Site Map | Corporate Citizenship | mobile m.ti.com (Mobile Version)

TI is a global semiconductor design and manufacturing company. Innovate with 100,000+ analog ICs and
embedded processors, along with software, tools and the industry’s largest sales/support staff.

© Copyright 1995-2013 Texas Instruments Incorporated. All rights reserved.
Trademarks | Privacy Policy | Terms of Use