Q: BQ2415X - Exiting Hi Z Mode
Q: Once the device (BQ24153A, BQ24156A, BQ24158) exits the standard path on the operational flow chart (pg. 15 in datasheet) and enters the high impedance mode, how does one return the device to normal operation?
A: You must perform an I2C write or power cycle the device to exit Hi Z mode.