• Not Answered

LM5072-80 PoE Power Up Sequence Problem

Need help with following for customer; please email me to get the schematic ...

I have attached the schematic for the Power over Ethernet part of our design, which uses the LM5072-80.  Please treat this information as confidential, according to the terms of our NDA.

We recently built 10 systems using this part.  Two of the parts failed during initial board test; two additional parts failed in systems – they worked for a while then failed during power cycling.  Any help that TI/National can provide in reviewing our design would be greatly appreciated – we are in preproduction now and need to resolve the issue immediately.