Welcome to the Sequencers Section of the TI E2E Support Community. Ask questions, share knowledge, explore ideas, and help solve problems with fellow engineers. To post a question, click on the forum tab then "New Post".
Q: TPS3510 FPO malfunction in customer MP stage by 4339
Hi experts,
We have TPS3510 issue. The issue is that the response time of FPO (Pin3) is too long than the normal parts when VS5 (Pin6) enter UVP condition. These failure parts have different response time. We also test these failure parts in the bench and we can duplicate the same symptom. So we need advice to fix this issue ASAP.
I alos attached test waveforms for reference.
Good: 160us Fail: 3.3sec
Thank you and regards
A: Re: TPS3510 FPO malfunction in customer MP stage by 313626
After reviewing schematic (not shown in this post) I noticed the customer has the TPS3510 PGO pin pulled up to 12V. The absolute maximum voltage shown in the datasheet for the PGO pin is 8V. The customers test is invalid and most likely damaging the devices. Applying voltages higher than the abs max to any pin can damage the device or cause unpredictable behavior.