In the specifications section on the wireless power consortium website it mentions that the performance requirements specification and compliance test specification are available for members only. Does TI have this information available?
http://www.wirelesspowerconsortium.com/developers/specification.html
The request concerns a BQ500210 design.
Hello Mike
The WPC standard has three parts
Part 1: Interface Definition
Part 2: Performance Requirements
Part 3: Compliance Testing
Only Part 1 is available to non WPC members.
Yes TI is a WPC member and has access to part 2 and 3. But cannot share this info with non members.
Bill
Best Regards,
Bill Johns, Applications Engineer
bqTESLA Wireless Power Products
Texas Instruments Inc
Dallas, Texas
Thanks Bill. For your reference, this pertained to the conference call we were on this morning.