The following tests have been selected:
BMC-PROT-SEQ-NOMRK-CP-ACC
UUT declared to meet Rev 2.0
Establish PD Mode...
Initial request accepted...
Request Swap (UUT from Sink to Source)...
Get Source Capabilities from Sink...
Source Capabilities seen...
Swap request completed...
Tester is now behaving as Sink.
PR_Swap was Accepted
Simulating Detach From UUT...
End of Tests.
No Vendor Info File inconsistencies found
| Events #35-36 | PD Sequence Start (Announce Source Capabilities) | |
| Event #35 | PD Message - Source Capabilities (from Tester) | |
| Event #36 | PD Message - GoodCRC (from UUT) (SOP) | |
| Events #37-43 | PD Sequence Start (Power Transition Request) | |
| Event #37 | PD Message - Request (from UUT) (SOP) | |
| Event #38 | PD Message - GoodCRC (from Tester) (SOP) | |
| Event #39 | PD Message - Accept (from Tester) (SOP) | |
| Event #40 | PD Message - GoodCRC (from UUT) (SOP) |
| Event #42 | PD Message - PS_RDY (from Tester) (SOP) | |
| Event #43 | PD Message - GoodCRC (from UUT) (SOP) |
| Events #45-48 | PD Sequence Start (Power Role Swap) | |
| Event #45 | PD Message - PR_Swap (from UUT) | |
| Event #46 | PD Message - GoodCRC (from Tester) (SOP) | |
| Event #47 | PD Message - Reject (from Tester) (SOP) | |
| Event #48 | PD Message - GoodCRC (from UUT) (SOP) | |
| Events #54-57 | PD Sequence Start (Request Source Capabilities) | |
| Event #54 | PD Message - Get_Src_Cap (from Tester) (SOP) | |
| Event #55 | PD Message - GoodCRC (from UUT) (SOP) | |
| Event #56 | PD Message - Source Capabilities (from UUT) | |
| Event #57 | PD Message - GoodCRC (from Tester) (SOP) | |
| Events #66-101 | PD Sequence Start (Power Role Swap) | |
| Event #66 | PD Message - PR_Swap (from Tester) | |
| Event #67 | PD Message - GoodCRC (from UUT) (SOP) | |
| Event #68 | PD Message - Accept (from UUT) (SOP) | |
| Event #69 | PD Message - GoodCRC (from Tester) (SOP) | |
| Event #85 | PD Message - PS_RDY (from Tester) (SOP) | |
| Event #86 | PD Message - GoodCRC (from UUT) (SOP) | |
| Event #89 | PD Message - PS_RDY (from UUT) (SOP) | |
| Event #90 | PD Message - GoodCRC (from Tester) (SOP) | |
| Events #94-94 | PD Sequence Start (Soft Reset) | |
| Event #94 | PD Message - Soft Reset (from Cable or UUT) (SOP') | |
| Events #95-95 | PD Sequence Start (Soft Reset) | |
| Event #95 | PD Message - Soft Reset (from Cable or UUT) (SOP') | |
| Events #96-96 | PD Sequence Start (Soft Reset) | |
| Event #96 | PD Message - Soft Reset (from Cable or UUT) (SOP') | |
| Events #97-97 | PD Sequence Start (Soft Reset) | |
| Event #97 | PD Message - Soft Reset (from Cable or UUT) (SOP') | |
| Events #98-98 | PD Sequence Start (VDM Discover ID) | |
| Event #98 | PD Message - VDM - Discover ID REQ (Rev 2.0) (from Cable or UUT) (SOP') | |
| Events #99-99 | PD Sequence Start (VDM Discover ID) | |
| Event #99 | PD Message - VDM - Discover ID REQ (Rev 2.0) (from Cable or UUT) (SOP') | |
| Events #100-100 | PD Sequence Start (VDM Discover ID) | |
| Event #100 | PD Message - VDM - Discover ID REQ (Rev 2.0) (from Cable or UUT) (SOP') | |
| Events #101-109 | PD Sequence Start (VDM Discover ID) | |
| Event #101 | PD Message - VDM - Discover ID REQ (Rev 2.0) (from Cable or UUT) (SOP') | |
| Events #102-103 | PD Sequence Start (Announce Source Capabilities) | |
| Event #102 | PD Message - Source Capabilities (from UUT) | |
| MessageID is not zero after a power role Swap. [PROT_MSG_HDR_3] | FAIL | |
| Event #103 | PD Message - GoodCRC (from Tester) (SOP) | |
| Events #104-109 | PD Sequence Start (Power Transition Request) | |
| Event #104 | PD Message - Request (from Tester) (SOP) | |
| Event #105 | PD Message - GoodCRC (from UUT) (SOP) | |
| Event #106 | PD Message - Accept (from UUT) (SOP) | |
| Event #107 | PD Message - GoodCRC (from Tester) (SOP) | |
| Event #108 | PD Message - PS_RDY (from UUT) (SOP) | |
| Event #109 | PD Message - GoodCRC (from Tester) (SOP) |
For Information Only:
0 Retries by UUT using SOP
6 Retries by UUT using SOP'
0 Retries by Tester using SOP
0 Retries by Tester using SOP'
Error PROT_MSG_HDR_3 found 1 time
1 Post-Run Error - FAIL
0 Runtime Errors
BMC-PROT-SEQ-NOMRK-CP-ACC - PASS
BMC-PROT-SEQ-NOMRK-CP-ACC Secondary - FAIL
BMC PHY Tx: [Required]
BMC PHY Rx: [Required]
BMC PHY Misc: [Required]
Protocol Specific: PASS
Power Specific: [Required]
Secondary: FAIL