Manufacturer |
|
Model Number |
|
Serial Number |
-1_PD3 |
Test Lab |
|
Test Engineer |
|
Remarks |
X |
Date and Time: |
20200116_153900 |
Parameter |
Value |
|---|---|
GRL USB-PD_C2 Serial No. |
218.316.218.081.251. |
GRL USB-PD Software Version |
1.3.16.18 |
GRL USB-PD Firmware Version |
1.3.16.0.15 |
GRL USB-PD Eload Firmware Version |
9.7/9.7 |
Board Calibration |
Calibration Success. |
App Mode |
 COMPLIANCE_TEST_PD3 |
Tx Mask |
true |
Rx Mask |
false |
RX mask Power selection |
Neutral Power |
Device Type |
DRP |
Cable IR drop Imp(R) |
0 |
Cable Type. |
GRL-SPL-Cable |
COMPLIANCE_TEST_PD3 CTS Version |
1.14 |
VIF File name |
|
Noise Pattern Generation: |
Two-Tone Noise |
VIF info |
*Since VIF was not loaded below test results are information Only. |
Test cases Execution Time: |
0h:32m:34s |
Parameter |
VendorInfoFile |
GetCapabilities |
|---|---|---|
VENDOR_NAME |
Intel |
|
VIF_PRODUCT_TYPE |
||
MODEL_PART_NUMBER |
||
PRODUCT_REVISION |
||
TID |
0 |
|
PORT_LABEL |
||
CONNECTOR_TYPE |
||
USB_PD_SUPPORT |
YES |
|
PD_PORT_TYPE |
||
MANUFACTURER_INFO_PID_PORT |
||
STRUCTURED_VDM_VERSION |
Version 2.0 |
|
TYPE_C_STATE_MACHINE |
||
PORT_BATTERY_POWERED |
NO |
|
BC_1_2_SUPPORT |
||
BC_1_2_CHARGING_PORT_TYPE |
||
PD_SPECIFICATION_REVISION |
Revision 3 |
|
SOP_CAPABLE |
YES |
|
SOP_P_CAPABLE |
YES |
|
SOP_PP_CAPABLE |
NO |
|
SOP_P_DEBUG_CAPABLE |
NO |
|
SOP_PP_DEBUG_CAPABLE |
NO |
|
SECURITY_MSGS_SUPPORTED |
NO |
|
MANUFACTURER_INFO_SUPPORTED |
YES |
|
MANUFACTURER_INFO_VID |
0x8087 |
|
MANUFACTURER_INFO_PID |
0x0 |
|
NUM_FIXED_BATTERIES |
0 |
|
NUM_SWAPPABLE_BATTERY_SLOTS |
0 |
|
USB_COMMS_CAPABLE |
YES |
|
DR_SWAP_TO_DFP_SUPPORTED |
NO |
|
DR_SWAP_TO_UFP_SUPPORTED |
NO |
|
UNCONSTRAINED_POWER |
YES |
|
VCONN_SWAP_TO_ON_SUPPORTED |
||
VCONN_SWAP_TO_OFF_SUPPORTED |
||
RESPONDS_TO_DISCOV_SOP_UFP |
||
RESPONDS_TO_DISCOV_SOP_DFP |
||
ATTEMPTS_DISCOV |
||
CHUNKING_IMPLEMENTED |
NO |
|
UNCHUNKED_EXTENDED_MESSAGES_SUPPORTED |
YES |
|
PRODUCT_TYPE_UFP |
||
PRODUCT_TYPE_DFP |
||
MODAL_OPERATION_SUPPORTED |
YES |
|
USB_VID |
0x8087 |
|
PID |
0x0 |
|
BCDDEVICE |
0x649 |
|
XID |
1105 |
|
DATA_CAPABLE_AS_USB_HOST |
YES |
|
DATA_CAPABLE_AS_USB_DEVICE |
YES |
|
PRODUCT_TYPE |
||
CABLE_HW_VERS |
||
CABLE_FW_VERS |
||
TYPE_C_TO_TYPE_A_B_C |
||
TYPE_C_TO_TYPE_C_CAPT_VDM_V2 |
||
TYPE_C_TO_PLUG_RECEPTACLE |
||
CABLE_LATENCY |
||
CABLE_TERMINATION_TYPE |
||
VBUS_THROUGH_CABLE |
||
CABLE_VBUS_CURRENT |
||
CABLE_SOP_PP_CONTROLLER |
||
CABLE_SUPERSPEED_SUPPORT |
||
MAX_VBUS_VOLTAGE_VDM_V2 |
||
ACCEPTS_PR_SWAP_AS_SRC |
||
ACCEPTS_PR_SWAP_AS_SNK |
||
REQUESTS_PR_SWAP_AS_SRC |
||
REQUESTS_PR_SWAP_AS_SNK |
||
FR_SWAP_SUPPORTED_AS_INITIAL_SINK |
||
AMA_FW_VERS |
||
AMA_HW_VERS |
||
AMA_SUPERSPEED_SUPPORT |
||
AMA_VBUS_REQD |
||
AMA_VCONN_POWER |
||
AMA_VCONN_REQD |
||
HOST_SPEED |
||
DEVICE_SPEED |
||
CABLE_NUM_SVIDS_MIN |
||
CABLE_NUM_SVIDS_MAX |
||
SVID_FIXED |
||
NUM_SVIDS_MIN |
1 |
|
NUM_SVIDS_MAX |
2 |
|
SVID1SOP |
- |
8087 |
SVID1Modes Min |
- |
1 |
SVID1Modes Max |
- |
1 |
SVID1Modes Fixed |
- |
YES |
SVID1Mode1 Enter Mode |
- |
NO |
SVID2SOP |
- |
FF01 |
SVID2Modes Min |
- |
1 |
SVID2Modes Max |
- |
1 |
SVID2Modes Fixed |
- |
YES |
SVID2Mode1 Enter Mode |
- |
YES |
TYPE_C_IMPLEMENTS_TRY_SRC |
||
TYPE_C_IMPLEMENTS_TRY_SNK |
||
RP_VALUE |
||
TYPE_C_IS_VCONN_POWERED_ACCESSORY |
||
TYPE_C_IS_DEBUG_TARGET_SRC |
||
TYPE_C_IS_DEBUG_TARGET_SNK |
||
TYPE_C_CAN_ACT_AS_HOST |
||
TYPE_C_CAN_ACT_AS_DEVICE |
||
TYPE_C_IS_ALT_MODE_CONTROLLER |
||
TYPE_C_IS_ALT_MODE_ADAPTER |
||
TYPE_C_POWER_SOURCE |
||
TYPE_C_PORT_ON_HUB |
||
TYPE_C_SUPPORTS_AUDIO_ACCESSORY |
||
CAPTIVE_CABLE |
||
TYPE_C_SOURCES_VCONN |
||
HOST_SUSPEND_SUPPORTED |
Parameter |
VendorInfoFile |
GetCapabilities |
|---|---|---|
PD_POWER_AS_SOURCE |
15000 |
|
USB_SUSPEND_MAY_BE_CLEARED |
YES |
|
SENDS_PINGS |
NO |
|
FR_SWAP_SUPPORTED_AS_SOURCE |
||
PD_OC_PROTECTION |
||
PD_OCP_METHOD |
||
NUM_SRC_PDOS |
1 |
|
Supply Type #1 |
- |
Fixed |
Peak Current #1 |
- |
0x0(A) |
Voltage #1 |
- |
0x64(5V) |
Max Current #1 |
- |
0x12C(3A) |
PD_POWER_AS_SINK |
0 |
|
NO_USB_SUSPEND_MAY_BE_SET |
NO |
|
GIVEBACK_MAY_BE_SET |
NO |
|
HIGHER_CAPABILITY_SET |
NO |
|
FR_SWAP_REQD_TYPE_C_CURRENT_AS_INITIAL_SOURCE |
0 |
|
NUM_SNK_PDOS |
1 |
|
Supply Type #1 |
- |
Fixed |
Voltage #1 |
- |
0x64(5V) |
OP Current #1 |
- |
0x0(A) |
Sl No |
Test ID |
Test Name |
Test Result |
|---|---|---|---|
1 |
TD.PD.LL3.E1 |
PASS |
|
2 |
TD.PD.LL3.E2 |
PASS |
|
3 |
TD.PD.LL3.E3 |
PASS |
|
4 |
TD.PD.SRC3.E1 |
PASS |
|
5 |
TD.PD.SRC3.E2 |
PASS |
|
6 |
TD.PD.SRC3.E3 |
PASS |
|
7 |
TD.PD.SRC3.E4 |
PASS |
|
8 |
TD.PD.SRC3.E5 |
PASS |
|
9 |
TD.PD.SRC3.E6 |
PASS |
|
10 |
TD.PD.SRC3.E7 |
PASS |
|
11 |
TD.PD.SRC3.E8 |
PASS |
|
12 |
TD.PD.SRC3.E9 |
TD.PD.SRC3.E9 Battery Status Fields Checks Invalid Battery reference |
PASS |
13 |
TD.PD.SRC3.E10 |
PASS |
|
14 |
TD.PD.SRC3.E11 |
PASS |
|
15 |
TD.PD.SRC3.E12 |
PASS |
|
16 |
TD.PD.SRC3.E13 |
PASS |
|
17 |
TD.PD.SRC3.E14 |
FAIL |
|
18 |
TD.PD.SRC3.E15 |
PASS |
|
19 |
TD.PD.SRC3.E16 |
PASS |
|
20 |
TD.PD.SRC3.E17 |
TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference |
PASS |
21 |
TD.PD.SRC3.E18 |
PASS |
|
22 |
TD.PD.SRC3.E19 |
PASS |
|
23 |
TD.PD.SRC3.E20 |
TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target |
FAIL |
24 |
TD.PD.SRC3.E21 |
TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref |
FAIL |
25 |
TD.PD.SRC3.E22 |
PASS |
|
26 |
TD.PD.SRC3.E23 |
PASS |
|
27 |
TD.PD.SRC3.E24 |
PASS |
|
28 |
TD.PD.SRC3.E25 |
PASS |
|
29 |
TD.PD.SRC3.E26 |
PASS |
|
30 |
TD.PD.SRC3.E27 |
NA |
|
31 |
TD.PD.SRC3.E28 |
NA |
|
32 |
TD.PD.SRC3.E29 |
NA |
|
33 |
TD.PD.SRC3.E30 |
NA |
|
34 |
TD.PD.SRC3.E31 |
NA |
|
35 |
TD.PD.SRC3.E32 |
FAIL |
|
36 |
TD.PD.SRC3.E33 |
PASS |
|
37 |
TD.PD.SRC3.E34 |
PASS |
|
38 |
TD.PD.SRC3.E35 |
PASS |
|
39 |
TD.PD.SRC3.E36 |
PASS |
|
40 |
TD.PD.SNK3.E1 |
PASS |
|
41 |
TD.PD.SNK3.E2 |
PASS |
|
42 |
TD.PD.SNK3.E3 |
PASS |
|
43 |
TD.PD.SNK3.E4 |
TD.PD.SNK3.E4 SenderResponseTimer Deadline Source Capabilities Extended |
PASS |
44 |
TD.PD.SNK3.E5 |
TD.PD.SNK3.E5 SenderResponseTimer Timeout Source Capabilities Extended |
PASS |
45 |
TD.PD.SNK3.E6 |
PASS |
|
46 |
TD.PD.SNK3.E7 |
PASS |
|
47 |
TD.PD.SNK3.E8 |
PASS |
|
48 |
TD.PD.SNK3.E9 |
PASS |
|
49 |
TD.PD.SNK3.E10 |
PASS |
|
50 |
TD.PD.SNK3.E11 |
PASS |
|
51 |
TD.PD.SNK3.E12 |
PASS |
|
52 |
TD.PD.SNK3.E13 |
NA |
|
53 |
TD.PD.SNK3.E14 |
NA |
|
54 |
TD.PD.SNK3.E15 |
FAIL |
|
55 |
TD.PD.SNK3.E16 |
PASS |
|
56 |
TD.PD.SNK3.E17 |
TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target |
FAIL |
57 |
TD.PD.SNK3.E18 |
TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref |
FAIL |
58 |
TD.PD.SNK3.E19 |
PASS |
|
59 |
TD.PD.VDM3.E1 |
PASS |
|
60 |
TD.PD.VDM3.E2 |
PASS |
|
61 |
TD.PD.PRSISNK3.E1 |
PASS |
Test Status |
Test Description |
|---|---|
  |
 1. TD.PD.LL3.E1 GoodCRC Specification Revision compatibility (Click to View Protocol Trace) |
  |
 2. TD.PD.LL3.E2 Retransmission (Click to View Protocol Trace) |
  |
 3. TD.PD.LL3.E3 GoodCRC Compatibility with PD2 (Click to View Protocol Trace) |
  |
 4. TD.PD.SRC3.E1 Source Capability Fields Checks (Click to View Protocol Trace) |
  |
 5. TD.PD.SRC3.E2 Accept Fields Checks (Click to View Protocol Trace) |
  |
 6. TD.PD.SRC3.E3 PSRDY Fields Checks (Click to View Protocol Trace) |
  |
 7. TD.PD.SRC3.E4 Specification Revision Check after Contract (Click to View Protocol Trace) |
  |
 8. TD.PD.SRC3.E5 Source Capabilities Extended sent timely (Click to View Protocol Trace) |
  |
 9. TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks_Unchunked(True): |
  |
 TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks_Unchunked(False): |
  |
 10. TD.PD.SRC3.E7 Battery Status sent Timely (Click to View Protocol Trace) |
  |
     DUT sent (0) Batteries on Source capabilities Extended Message |
  |
 11. TD.PD.SRC3.E8 Battery Status Fields Checks (Click to View Protocol Trace) |
  |
 12. TD.PD.SRC3.E9 Battery Status Fields Checks Invalid Battery reference (Click to View Protocol Trace) |
  |
 13. TD.PD.SRC3.E10 Unrecognized Message Received in Ready State (Click to View Protocol Trace) |
  |
 14. TD.PD.SRC3.E11 Get Status Fields Checks (Click to View Protocol Trace) |
  |
 15. TD.PD.SRC3.E12 Get Battery Status Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E12 Get Battery Status Fields Checks_Unchunked(True): |
  |
 TD.PD.SRC3.E12 Get Battery Status Fields Checks_Unchunked(False): |
  |
 16. TD.PD.SRC3.E13 Status sent timely (Click to View Protocol Trace) |
  |
 17. TD.PD.SRC3.E14 Status Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E14 Status Fields Checks_Unchunked(True): |
  |
     DataSize was 5 bytes but expected 6 bytes |
  |
 TD.PD.SRC3.E14 Status Fields Checks_Unchunked(False): |
  |
     DataSize was 5 bytes but expected 6 bytes |
  |
 18. TD.PD.SRC3.E15 Battery Capabilities sent timely (Click to View Protocol Trace) |
  |
     DUT sent (0) batteries in Source capabilities Extended message |
  |
 19. TD.PD.SRC3.E16 Battery Capabilities Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E16 Battery Capabilities Fields Checks_Unchunked(True): |
  |
 TD.PD.SRC3.E16 Battery Capabilities Fields Checks_Unchunked(False): |
  |
 20. TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference_Unchunked(True): |
  |
 TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference_Unchunked(False): |
  |
 21. TD.PD.SRC3.E18 Manufacturer Info Sent Timely (Click to View Protocol Trace) |
  |
 22. TD.PD.SRC3.E19 Manufacturer Info Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E19 Manufacturer Info Fields Checks_Unchunked(True): |
  |
 TD.PD.SRC3.E19 Manufacturer Info Fields Checks_Unchunked(False): |
  |
 23. TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(True): |
  |
     DataSize was 4 bytes but expected 18 bytes |
  |
 TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(False): |
  |
     No.of data objects was 2 but expected 5 |
  |
 24. TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(True): |
  |
     DataSize was 4 bytes but expected 18 bytes |
  |
 TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(False): |
  |
     No.of data objects was 2 but expected 5 |
  |
 25. TD.PD.SRC3.E22 Cable Type Detection (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E22 Cable Type Detection_1: |
  |
     DUT incapable to offer current >3A or voltage >20V |
  |
 26. TD.PD.SRC3.E23 Vconn Swap (Click to View Protocol Trace) |
  |
 27. TD.PD.SRC3.E24 Unexpected Message Received in Ready State (Click to View Protocol Trace) |
  |
 28. TD.PD.SRC3.E25 Receiving chunked extended message (Click to View Protocol Trace) |
  |
 29. TD.PD.SRC3.E26 Soft Reset sent regardless of Rp value (Click to View Protocol Trace) |
  |
 30. TD.PD.SRC3.E27 PPS Status Sent Timely (Click to View Protocol Trace) |
  |
     Tester could not find APDO's{0} |
  |
 31. TD.PD.SRC3.E28 PPS Status Fields Check (Click to View Protocol Trace) |
  |
     Tester could not find APDO's{0} |
  |
 32. TD.PD.SRC3.E29 SourcePPSCommTimer Deadline (Click to View Protocol Trace) |
  |
     Tester could not find APDO's{0} |
  |
 33. TD.PD.SRC3.E30 SourcePPSCommTimer Timeout (Click to View Protocol Trace) |
  |
     DUT does not contains APDO's{0} |
  |
 34. TD.PD.SRC3.E31 SourcePPSCommTimer Stopped (Click to View Protocol Trace) |
  |
     DUT does not contains APDO's{0} |
  |
 35. TD.PD.SRC3.E32 ChunkSenderResponseTimer Timeout (Click to View Protocol Trace) |
  |
     DUT responded with Reserved message |
  |
 36. TD.PD.SRC3.E33 Country Codes Sent Timely (Click to View Protocol Trace) |
  |
     DUT responded with Not Supported message |
  |
 37. TD.PD.SRC3.E34 Country Codes Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E34 Country Codes Fields Checks_Unchunked(True): |
  |
     DUT responded with Not Supported message |
  |
 TD.PD.SRC3.E34 Country Codes Fields Checks_Unchunked(False): |
  |
     DUT responded with Not Supported message |
  |
 38. TD.PD.SRC3.E35 Country Info Sent Timely (Click to View Protocol Trace) |
  |
     DUT responded with Not Supported message |
  |
 39. TD.PD.SRC3.E36 Country Info Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SRC3.E36 Country Info Fields Checks_Unchunked(True): |
  |
     DUT responded with Not Supported message |
  |
 TD.PD.SRC3.E36 Country Info Fields Checks_Unchunked(False): |
  |
     DUT responded with Not Supported message |
  |
 40. TD.PD.SNK3.E1 Request Fields Checks (Click to View Protocol Trace) |
  |
 41. TD.PD.SNK3.E2 Unrecognized Message Received in Ready State (Click to View Protocol Trace) |
  |
 42. TD.PD.SNK3.E3 Get Source Cap Extended Fields Checks (Click to View Protocol Trace) |
  |
 43. TD.PD.SNK3.E4 SenderResponseTimer Deadline Source Capabilities Extended (Click to View Protocol Trace) |
  |
 44. TD.PD.SNK3.E5 SenderResponseTimer Timeout Source Capabilities Extended (Click to View Protocol Trace) |
  |
     Dut not initiated Hardreset/softreset |
  |
 45. TD.PD.SNK3.E6 Get Status Fields Checks (Click to View Protocol Trace) |
  |
     DUT not responded for Alert message. |
  |
 46. TD.PD.SNK3.E7 Get Battery Status Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SNK3.E7 Get Battery Status Fields Checks_Unchunked(True): |
  |
     DUT not responded for Alert message. |
  |
 TD.PD.SNK3.E7 Get Battery Status Fields Checks_Unchunked(False): |
  |
     DUT responded with Get status message. |
  |
 47. TD.PD.SNK3.E8 Status sent timely (Click to View Protocol Trace) |
  |
 48. TD.PD.SNK3.E9 Manufacturer Info Sent Timely (Click to View Protocol Trace) |
  |
 49. TD.PD.SNK3.E10 Source Capabilities Extended sent timely (Click to View Protocol Trace) |
  |
 50. TD.PD.SNK3.E11 Receiving chunked extended message (Click to View Protocol Trace) |
  |
 51. TD.PD.SNK3.E12 Soft Reset sent regardless of Rp value (Click to View Protocol Trace) |
  |
 52. TD.PD.SNK3.E13 SinkPPSPeriodicTimer Timeout (Click to View Protocol Trace) |
  |
     DUT doesn't Requested APDO |
  |
 53. TD.PD.SNK3.E14 Request Fields Checks PPS (Click to View Protocol Trace) |
  |
     DUT doesn't Requested APDO |
  |
 54. TD.PD.SNK3.E15 Status Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SNK3.E15 Status Fields Checks_Unchunked(True): |
  |
     DataSize was 5 bytes but expected 6 bytes |
  |
 TD.PD.SNK3.E15 Status Fields Checks_Unchunked(false): |
  |
     DataSize was 5 bytes but expected 6 bytes |
  |
 55. TD.PD.SNK3.E16 Manufacturer Info Fields Checks (Click to View Protocol Trace) |
  |
 TD.PD.SNK3.E16 Manufacturer Info Fields Checks_Unchunked(True): |
  |
 TD.PD.SNK3.E16 Manufacturer Info Fields Checks_Unchunked(false): |
  |
 56. TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target (Click to View Protocol Trace) |
  |
 TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(True): |
  |
     DataSize was 4 bytes but expected 18 bytes |
  |
 TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(False): |
  |
     No.of data objects was 2 but expected 5 |
  |
 57. TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref (Click to View Protocol Trace) |
  |
 TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(True): |
  |
     DataSize was 4 bytes but expected 18 bytes |
  |
 TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(False): |
  |
     No.of data objects was 2 but expected 5 |
  |
 58. TD.PD.SNK3.E19 ChunkSenderResponseTimer Timeout (Click to View Protocol Trace) |
  |
 59. TD.PD.VDM3.E1 Fields Checks Discover Identity (Click to View Protocol Trace) |
  |
 60. TD.PD.VDM3.E2 Unrecognized VID in Unstructured VDM (Click to View Protocol Trace) |
  |
 61. TD.PD.PRSISNK3.E1 Collision Avoidance after PR-Swap (Click to View Protocol Trace) |