GRL

GRL-USB-PD-C2 Compliance Test Report



DUT Information

Manufacturer

Model Number

Serial Number

-1_CE

Test Information

Test Lab

Test Engineer

Remarks

Date and Time:

20200116_145206

Controller and Instrument Information

Parameter

Value

GRL USB-PD_C2 Serial No.

218.316.218.081.251.

GRL USB-PD Software Version

1.3.16.18

GRL USB-PD Firmware Version

1.3.16.0.15

GRL USB-PD Eload Firmware Version

9.7/9.7

Board Calibration

Calibration Success.

App Mode

 COMMUNICATION_ENGINE_TESTS

Tx Mask

true

Rx Mask

false

RX mask Power selection

Neutral Power

Device Type

DRP

Cable IR drop Imp(R)

0

Cable Type.

GRL-SPL-Cable

COMMUNICATION_ENGINE_TESTS CTS Version

1.09

VIF File name

Noise Pattern Generation:

Two-Tone Noise

VIF info

*Since VIF was not loaded below test results are information Only.

Test cases Execution Time:

0h:0m:49s

Product Capabilities

Parameter

VendorInfoFile

GetCapabilities

VENDOR_NAME

Intel

VIF_PRODUCT_TYPE

MODEL_PART_NUMBER

PRODUCT_REVISION

TID

0

PORT_LABEL

CONNECTOR_TYPE

USB_PD_SUPPORT

YES

PD_PORT_TYPE

MANUFACTURER_INFO_PID_PORT

STRUCTURED_VDM_VERSION

Version 2.0

TYPE_C_STATE_MACHINE

PORT_BATTERY_POWERED

NO

BC_1_2_SUPPORT

BC_1_2_CHARGING_PORT_TYPE

PD_SPECIFICATION_REVISION

Revision 3

SOP_CAPABLE

YES

SOP_P_CAPABLE

YES

SOP_PP_CAPABLE

NO

SOP_P_DEBUG_CAPABLE

NO

SOP_PP_DEBUG_CAPABLE

NO

SECURITY_MSGS_SUPPORTED

NO

MANUFACTURER_INFO_SUPPORTED

YES

MANUFACTURER_INFO_VID

0x8087

MANUFACTURER_INFO_PID

0x0

NUM_FIXED_BATTERIES

0

NUM_SWAPPABLE_BATTERY_SLOTS

0

USB_COMMS_CAPABLE

YES

DR_SWAP_TO_DFP_SUPPORTED

NO

DR_SWAP_TO_UFP_SUPPORTED

NO

UNCONSTRAINED_POWER

YES

VCONN_SWAP_TO_ON_SUPPORTED

VCONN_SWAP_TO_OFF_SUPPORTED

RESPONDS_TO_DISCOV_SOP_UFP

RESPONDS_TO_DISCOV_SOP_DFP

ATTEMPTS_DISCOV

CHUNKING_IMPLEMENTED

NO

UNCHUNKED_EXTENDED_MESSAGES_SUPPORTED

YES

PRODUCT_TYPE_UFP

PRODUCT_TYPE_DFP

MODAL_OPERATION_SUPPORTED

YES

USB_VID

0x8087

PID

0x0

BCDDEVICE

0x649

XID

1105

DATA_CAPABLE_AS_USB_HOST

YES

DATA_CAPABLE_AS_USB_DEVICE

YES

PRODUCT_TYPE

CABLE_HW_VERS

CABLE_FW_VERS

TYPE_C_TO_TYPE_A_B_C

TYPE_C_TO_TYPE_C_CAPT_VDM_V2

TYPE_C_TO_PLUG_RECEPTACLE

CABLE_LATENCY

CABLE_TERMINATION_TYPE

VBUS_THROUGH_CABLE

CABLE_VBUS_CURRENT

CABLE_SOP_PP_CONTROLLER

CABLE_SUPERSPEED_SUPPORT

MAX_VBUS_VOLTAGE_VDM_V2

ACCEPTS_PR_SWAP_AS_SRC

ACCEPTS_PR_SWAP_AS_SNK

REQUESTS_PR_SWAP_AS_SRC

REQUESTS_PR_SWAP_AS_SNK

FR_SWAP_SUPPORTED_AS_INITIAL_SINK

AMA_FW_VERS

AMA_HW_VERS

AMA_SUPERSPEED_SUPPORT

AMA_VBUS_REQD

AMA_VCONN_POWER

AMA_VCONN_REQD

HOST_SPEED

DEVICE_SPEED

CABLE_NUM_SVIDS_MIN

CABLE_NUM_SVIDS_MAX

SVID_FIXED

NUM_SVIDS_MIN

1

NUM_SVIDS_MAX

2

SVID1SOP

-

8087

SVID1Modes Min

-

1

SVID1Modes Max

-

1

SVID1Modes Fixed

-

YES

SVID1Mode1 Enter Mode

-

NO

SVID2SOP

-

FF01

SVID2Modes Min

-

1

SVID2Modes Max

-

1

SVID2Modes Fixed

-

YES

SVID2Mode1 Enter Mode

-

YES

TYPE_C_IMPLEMENTS_TRY_SRC

TYPE_C_IMPLEMENTS_TRY_SNK

RP_VALUE

TYPE_C_IS_VCONN_POWERED_ACCESSORY

TYPE_C_IS_DEBUG_TARGET_SRC

TYPE_C_IS_DEBUG_TARGET_SNK

TYPE_C_CAN_ACT_AS_HOST

TYPE_C_CAN_ACT_AS_DEVICE

TYPE_C_IS_ALT_MODE_CONTROLLER

TYPE_C_IS_ALT_MODE_ADAPTER

TYPE_C_POWER_SOURCE

TYPE_C_PORT_ON_HUB

TYPE_C_SUPPORTS_AUDIO_ACCESSORY

CAPTIVE_CABLE

TYPE_C_SOURCES_VCONN

HOST_SUSPEND_SUPPORTED

Power Capabilities

Parameter

VendorInfoFile

GetCapabilities

PD_POWER_AS_SOURCE

15000

USB_SUSPEND_MAY_BE_CLEARED

YES

SENDS_PINGS

NO

FR_SWAP_SUPPORTED_AS_SOURCE

PD_OC_PROTECTION

PD_OCP_METHOD

NUM_SRC_PDOS

1

Supply Type #1

-

Fixed

Peak Current #1

-

0x0(A)

Voltage #1

-

0x64(5V)

Max Current #1

-

0x12C(3A)

PD_POWER_AS_SINK

0

NO_USB_SUSPEND_MAY_BE_SET

NO

GIVEBACK_MAY_BE_SET

NO

HIGHER_CAPABILITY_SET

NO

FR_SWAP_REQD_TYPE_C_CURRENT_AS_INITIAL_SOURCE

0

NUM_SNK_PDOS

1

Supply Type #1

-

Fixed

Voltage #1

-

0x64(5V)

OP Current #1

-

0x0(A)

Test Result Summary

Sl No

Test ID

Test Name

Test Result

1

TDA.2.1.1.1

TDA.2.1.1.1 BMC PHY TX EYE

PASS

2

TDA.2.1.1.2

TDA.2.1.1.2 BMC PHY TX BIT

PASS

3

TDA.2.1.2.2

TDA.2.1.2.2 BMC PHY RX INT REJ

PASS

4

TDA.2.1.2.1

TDA.2.1.2.1 BMC PHY RX BUSIDL

FAIL

5

TDA.2.1.3.1

TDA.2.1.3.1 BMC PHY TERM

PASS

6

TDA.2.1.3.2

TDA.2.1.3.2 BMC PHY MSG

PASS

7

TDA.2.2.1

TDA.2.2.1 BMC PROT SEQ GETCAPS

PASS

8

TDA.2.2.2.1

TDA.2.2.2.1 BMC PROT SEQ CHKCAB P PC

PASS

9

TDA.2.2.2.2

TDA.2.2.2.2 BMC PROT SEQ CHKCAP NOMARK P PC

NA

10

TDA.2.2.2.3

TDA.2.2.2.3 BMC PROT SEQ CHKCAP CP ACC

PASS

11

TDA.2.2.2.4

TDA.2.2.2.4 BMC PROT SEQ CHKCAP NOMRK CP ACC

NA

12

TDA.2.2.3

TDA.2.2.3 BMC PROT SEQ DRSWAP

NA

13

TDA.2.2.4

TDA.2.2.4 BMC PROT SEQ VCSWAP DFP

NA

14

TDA.2.2.5

TDA.2.2.5 BMC PROT DISCOV

NA

15

TDA.2.2.6

TDA.2.2.6 BMC PROT SEQ PRSWAP

NA

16

TDA.2.2.7

TDA.2.2.7 BMC PROT BIST NOT 5V SRC

PASS

17

TDA.2.2.8

TDA.2.2.8 BMC PROT REV NUM

NA

18

TDA.2.2.9

TDA.2.2.9 BMC PROT GSC REC

PASS

19

TDA.2.2.10

TDA.2.2.10 BMC PROT IGN PPS

NA

20

TDA.2.3.1.1

TDA.2.3.1.1 POW SRC LOAD P PC

PASS

21

TDA.2.3.1.2

TDA.2.3.1.2 POW SRC LOAD CP ACC

PASS

22

TDA.2.3.2.1

TDA.2.3.2.1 POW SRC TRANS P PC

PASS

23

TDA.2.3.2.2

TDA.2.3.2.2 POW SRC TRANS CP ACC

NA

24

TDA.2.3.3.1

TDA.2.3.3.1 POW SNK TRANS C CP

FAIL

25

TDA.2.3.3.2

TDA.2.3.3.2 POW SNK TRANS PC

NA

Detailed Test Result

Test Status

Test Description

  PASS

 1. TDA.2.1.1.1 BMC PHY TX EYE (Click to View Protocol Trace)

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-1:

 

     Valid Protocol response for BIST Request

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-2:

 

     Valid BIST response pattern

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-3:

 

     Eye diagram plot

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-4:

 

     BIST pattern duration 45.6672013 mS (Limit <= 60ms)

  PASS

 BMC_PHY_TX_EYE_5:

 

     Rise time:
Average value = 397.900435 nS
Minimum value = 392.514188 nS
Maximum value = 403.665854 nS
Minimum Limit = 300 ns

Fall time:
Average value = 467.004366 nS
Minimum value = 461.526877 nS
Maximum value = 471.993242 nS
Minimum Limit = 300 ns

  PASS

 2. TDA.2.1.1.2 BMC PHY TX BIT (Click to View Protocol Trace)

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-1:

 

     Valid Protocol response for BIST Request

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-2:

 

     Valid BIST response pattern

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-3:

 

     Bit Rate is 296.075 Kbps. Test limit (270 ~ 330) Kbps

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-4:

 

     Bit Rate is 0.001 %. Test limit: X < 0.25%

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-5:

 

     BIST pattern duration 45.6672013 mS (Limit <= 60ms)

  PASS

 3. TDA.2.1.2.2 BMC PHY RX INT REJ (Click to View Protocol Trace)

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_1_TstrSource:

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_2_TstrSourceNoiseGrp1:

 

     Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_3_TstrSourceNoiseGrp2:

 

     Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_4_TstrSink:

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_2_TstrSinkNoiseGrp1:

 

     Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_5_TstrSinkNoiseGrp3:

 

     Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  FAIL

 4. TDA.2.1.2.1 BMC PHY RX BUSIDL (Click to View Protocol Trace)

  PASS

 TDA.2.1.2.1 BMC PHY RX BUSIDL1_TstrSink:

  FAIL

 TDA.2.1.2.1 BMC PHY RX BUSIDL2_TstrSink:

 

     DUT sent GoodCRC when CCLine is not idle, Verify Protocol Capture and confirm Failure.

  PASS

 TDA.2.1.2.1 BMC PHY RX BUSIDL3_TstrSink:

  PASS

 5. TDA.2.1.3.1 BMC PHY TERM (Click to View Protocol Trace)

  PASS

 TDA.2.1.3.1 BMC PHY TERM_1:

  PASS

 TDA.2.1.3.1 BMC PHY TERM_2:

 

      CC-line voltage = 1.767V

  PASS

 6. TDA.2.1.3.2 BMC PHY MSG (Click to View Protocol Trace)

  NA

 TDA.2.1.3.2 BMC PHY MSG_SOPs_BIST_1:

 

     Vendor Info File was not Loaded.

  PASS

 TDA.2.1.3.2 BMC PHY MSG_PHY_ERR_2:

  PASS

                BMC_PHY_MSG_6:

  PASS

                BMC_PHY_MSG_7:

  PASS

                BMC_PHY_MSG_8:

  PASS

                BMC_PHY_MSG_9:

  PASS

                BMC_PHY_MSG_10:

  PASS

                BMC_PHY_MSG_11:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_init_3:

  PASS

                BMC_PHY_MSG_12:

  PASS

                BMC_PHY_MSG_13:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_Cable_Reset_4:

  PASS

                BMC_PHY_MSG_15:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_Rpt_5:

  PASS

                BMC_PHY_MSG_18:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_HardRst_6:

  PASS

                BMC_PHY_MSG_16:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_SoftRst_7:

  PASS

                BMC_PHY_MSG_14:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_CRCCheck_8:

  PASS

                BMC_PHY_MSG_19:

  PASS

                PROT_PROC_GCRC_UUT_1:

  PASS

 7. TDA.2.2.1 BMC PROT SEQ GETCAPS (Click to View Protocol Trace)

  PASS

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source)_(1):

 

                         Protocol Index # #36870

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source)_(2):

  PASS

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source)_(3):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source)_(4):

 

                         DUT responded with sink capability message at protocol index # #36882

  PASS

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT-Type-(Sink):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT-Type-(Sink)_(1):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT-Type-(Sink)_(2):

 

                         DUT responded with source cap message at protocol index # #36906

  PASS

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type_(Sink):

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type_(Sink)_(3):

 

                         DUT responded with sink_cap message at protocol index # #36910

  PASS

                TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type_(Sink)_(4):

  PASS

 8. TDA.2.2.2.1 BMC PROT SEQ CHKCAB P PC (Click to View Protocol Trace)

  PASS

 BMC_PROT_SEQ_CHKCAB_P_PC_1_DISC_SOP1:

  PASS

 BMC_PROT_SEQ_CHKCAB_ P_PC _2_(>3A):

  NA

 9. TDA.2.2.2.2 BMC PROT SEQ CHKCAP NOMARK P PC (Click to View Protocol Trace)

 

     Test is not applicable for captive cable DUT's.

  PASS

 10. TDA.2.2.2.3 BMC PROT SEQ CHKCAP CP ACC (Click to View Protocol Trace)

  PASS

 BMC_PROT_SEQ_CHKCAB_ CP_ACC _1(PRSwap):

  PASS

 BMC_PROT_SEQ_CHKCAB_CP_ACC_2_DISC(SOP1):

  PASS

 BMC_PROT_SEQ_CHKCAB_CP_ACC_3_(>3A):

  NA

 11. TDA.2.2.2.4 BMC PROT SEQ CHKCAP NOMRK CP ACC (Click to View Protocol Trace)

 

     Test is not applicable for captive cable DUT's.

  NA

 12. TDA.2.2.3 BMC PROT SEQ DRSWAP (Click to View Protocol Trace)

 

     Vendor Info is not imported

  NA

 13. TDA.2.2.4 BMC PROT SEQ VCSWAP DFP (Click to View Protocol Trace)

 

     Vendor Info VCONN_SWAP_TO_OFF_SUPPORTED field is not updated

  NA

 14. TDA.2.2.5 BMC PROT DISCOV (Click to View Protocol Trace)

 

     Vendor Info is not imported

  NA

 15. TDA.2.2.6 BMC PROT SEQ PRSWAP (Click to View Protocol Trace)

 

     Vendor Info is not imported

  PASS

 16. TDA.2.2.7 BMC PROT BIST NOT 5V SRC (Click to View Protocol Trace)

  NA

 17. TDA.2.2.8 BMC PROT REV NUM (Click to View Protocol Trace)

 

     Vendor Info is not imported

  PASS

 18. TDA.2.2.9 BMC PROT GSC REC (Click to View Protocol Trace)

  PASS

 TDA.2.2.9 BMC PROT GSC REC_Get_SrcCap:

  NA

 19. TDA.2.2.10 BMC PROT IGN PPS (Click to View Protocol Trace)

 

     Test case is not applicable for Revision 3.0 DUT's

  NA

 TDA.2.2.10 BMC PROT IGN PPS_1:

  NA

 TDA.2.2.10 BMC PROT IGN PPS_2:

  NA

 TDA.2.2.10 BMC PROT IGN PPS_3:

  PASS

 20. TDA.2.3.1.1 POW SRC LOAD P PC (Click to View Protocol Trace)

  PASS

 TDA.2.3.1.1 POW SRC LOAD P PC_PDO_1:

  PASS

 TDA.2.3.1.1 POW SRC LOAD P PC_PDO_1_2:

 

     Measured VBUS voltage value between start time 17.0410868S and stop time = 17.0425868S is = 5.30654762V limit[FS :4.75000000V~5.25000000V] after PS_RDY protocol index # #0

  PASS

                PROT_PROC_GCRC_UUT_1:

  PASS

                PROT_PROC_REQ_TSTR_4:

  PASS

                PROT_PROC_REQ_TSTR_5:

  PASS

                PROT_PROC_REQ_TSTR_6:

  PASS

                PROT_PROC_REQ_TSTR_9:

 

                         Measured VBUS voltage value between start time 17.0410868S and stop time = 17.0425868S is = 5.30654762V limit[FS :4.75000000V~5.25000000V] after PS_RDY protocol index # #37293

  PASS

 DUT VBUS voltage before load of 0A is 5.30447V, voltage after Load: 5.3056V , Limit:[4.75-5.5V] at Protocol index #37299[ Measurement timeStamp24.4937653S]:

  PASS

 DUT VBUS voltage before load of 0.75A is 5.30556V, voltage after Load: 5.3041V , Limit:[4.75-5.5V] at Protocol index #37305 [Measurement timestamp :25.1347825S]:

  PASS

 DUT VBUS voltage before load of 1.5A is 5.22013V, voltage after Load: 5.1593V , Limit:[4.75-5.5V] at Protocol index #37311 [Measurement timestamp :25.7757677S]:

  PASS

 DUT VBUS voltage before load of 2.25A is 5.1316V, voltage after Load: 5.0782V , Limit:[4.75-5.5V] at Protocol index #37317 [Measurement timestamp :26.4167737S]:

  PASS

 DUT VBUS voltage before load of 3.0A is 5.04835V, voltage after Load: 4.9983V , Limit:[4.75-5.5V] at Protocol index #37323 [Measurement timestamp :27.0577314S]:

  PASS

 DUT VBUS voltage before load of 2.25A is 4.98259V, voltage after Load: 5.0483V , Limit:[4.75-5.5V] at Protocol index #37329 [Measurement timestamp :27.6987677S]:

  PASS

 DUT VBUS voltage before load of 1.5A is 5.07258V, voltage after Load: 5.132V , Limit:[4.75-5.5V] at Protocol index #37335 [Measurement timestamp :28.3397777S]:

  PASS

 DUT VBUS voltage before load of 0.75A is 5.15928V, voltage after Load: 5.2179V , Limit:[4.75-5.5V] at Protocol index #37341 [Measurement timestamp :28.9807651S]:

  PASS

 DUT VBUS voltage before load of 0A is 5.25692V, voltage after Load: 5.3057V , Limit:[4.75-5.5V] at Protocol index #37347[ Measurement timeStamp29.6217690S]:

  PASS

 PT_PROT_PROC_HR_TSTR_3:

  PASS

                PROT_PROC_HR_TSTR_1:

  PASS

                PROT_PROC_HR_TSTR_2:

  PASS

                PROT_PROC_HR_TSTR_3:

  PASS

                PROT_PROC_HR_TSTR_4:

 

                         Vbus Voltage after 660ms is :0.02201V

  PASS

                PROT_PROC_HR_TSTR_5:

 

                         Vbus voltage at >1s is:5.30228V

  PASS

                PROT_PROC_GCRC_UUT_1:

  PASS

 PT_TDA_2_3_1_1 POW SRC LOAD P PC_RequestHigherCurrent_PDO_1:

  PASS

 21. TDA.2.3.1.2 POW SRC LOAD CP ACC (Click to View Protocol Trace)

  PASS

 TDA_2_3_1_2_POW_SRC_LOAD_CP_ACC_1:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_1:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_1(3):

 

     Measured VBUS voltage value between start time 22.0237208S and stop time = 22.0252208S is = 5.30441375V limit[FS :4.75000000V~5.25000000V] after PS_RDY protocol index # #0

  PASS

                PROT_PROC_GCRC_UUT_1:

  PASS

                PROT_PROC_REQ_TSTR_4:

  PASS

                PROT_PROC_REQ_TSTR_5:

  PASS

                PROT_PROC_REQ_TSTR_6:

  PASS

                PROT_PROC_REQ_TSTR_9:

 

                         Measured VBUS voltage value between start time 22.0237208S and stop time = 22.0252208S is = 5.30441375V limit[FS :4.75000000V~5.25000000V] after PS_RDY protocol index # #37438

  PASS

 PT_TDA_2_3_1_2 POW SRC LOAD CP ACC_PROT_PROC_HR_TSTR:

  PASS

                PROT_PROC_HR_TSTR_1:

  PASS

                PROT_PROC_HR_TSTR_2:

  PASS

                PROT_PROC_HR_TSTR_3:

  PASS

                PROT_PROC_HR_TSTR_4:

 

                         Vbus Voltage after 660ms is :0.02201V

  PASS

                PROT_PROC_HR_TSTR_5:

 

                         Vbus voltage at >1s is:5.30228V

  PASS

                PROT_PROC_GCRC_UUT_1:

  PASS

 22. TDA.2.3.2.1 POW SRC TRANS P PC (Click to View Protocol Trace)

 

     DUT advertised only PDO

  NA

 23. TDA.2.3.2.2 POW SRC TRANS CP ACC (Click to View Protocol Trace)

 

     Vendor info file was not loaded, Please load it and re-run again

  FAIL

 24. TDA.2.3.3.1 POW SNK TRANS C CP (Click to View Protocol Trace)

 

     VIF file was not loaded.

  PASS

 TDA.2.3.3.1 POW SNK TRANS C CP_1:

  PASS

 TDA.2.3.3.1 POW SNK TRANS C CP_3:

  PASS

 TDA.2.3.3.1 POW SNK TRANS C CP_2:

  NA

 25. TDA.2.3.3.2 POW SNK TRANS PC (Click to View Protocol Trace)

 

      DUT not accepted PR_Swap message. Vendor info not loaded