Date and time |
Thursday, 24 May 2018 14:53:31 GMT+2 |
Vendor |
pascal |
Product |
dry run |
Product revision |
comecer |
Test ID |
1 |
Generator used |
Ellisys USB Explorer 350 (EX350-62463) |
Analyzer used |
None |
Software version |
Report generated with version 3.1.6688 |
Overall result |
Failed |
Test status |
Last updated on |
||
Failed |
|||
Passed |
Stable |
2015-09-24 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Passed |
Stable |
2016-10-27 |
|
Failed |
Stable |
2016-07-11 |
|
Not Applicable |
Stable |
2016-05-11 |
|
Not Applicable |
Stable |
2016-07-01 |
|
Not Applicable |
Stable |
2015-10-22 |
|
Passed |
|||
Passed |
Stable |
2015-06-17 |
|
Failed |
|||
Passed |
Stable |
2017-09-24 |
|
Passed |
Stable |
2017-02-10 |
|
Passed |
Stable |
2016-08-12 |
|
Passed |
Beta |
2017-12-06 |
|
Passed |
Beta |
2017-06-19 |
|
Not Applicable |
RC |
2016-07-01 |
|
Not Applicable |
RC |
2016-10-27 |
|
Failed |
RC |
2018-04-08 |
|
Passed |
RC |
2018-04-08 |
|
Not Applicable |
RC |
2017-04-03 |
|
Not Applicable |
RC |
2016-11-04 |
|
Not Applicable |
Stable |
2016-06-17 |
|
Not Applicable |
RC |
2017-04-10 |
|
Not Applicable |
RC |
2017-02-10 |
|
Not Applicable |
RC |
2016-01-18 |
|
Not Applicable |
Beta |
2017-02-10 |
|
Passed |
|||
Passed |
Stable |
2015-08-18 |
|
Not Applicable |
Stable |
2016-02-10 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Passed |
Stable |
2016-11-04 |
|
Passed |
Stable |
2016-01-20 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-11-27 |
|
Passed |
Stable |
2015-08-21 |
|
Passed |
Stable |
2015-08-21 |
|
Passed |
Stable |
2015-08-21 |
|
Passed |
Stable |
2015-08-21 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
|||
Passed |
Stable |
2016-09-22 |
|
Passed |
Stable |
2016-08-17 |
|
Passed |
Stable |
2016-08-17 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2017-09-27 |
|
Passed |
|||
Failed |
|||
Failed |
Stable |
2015-09-23 |
|
Failed |
Stable |
2015-09-23 |
|
Passed |
Stable |
2015-08-27 |
|
Failed |
Stable |
2016-06-17 |
|
Passed |
Stable |
2015-08-27 |
|
Passed |
Stable |
2015-08-27 |
|
Passed |
Stable |
2015-08-27 |
|
Passed |
Stable |
2015-08-27 |
|
Passed |
Stable |
2015-09-24 |
|
Failed |
Stable |
2016-03-10 |
|
» TD.PD.SNK.E11 PDO Transition |
Deprecated |
2016-09-19 |
|
Passed |
Beta |
2016-09-19 |
|
Failed |
|||
Not Applicable |
Stable |
2015-08-18 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Not Applicable |
Stable |
2016-05-09 |
|
Not Applicable |
Stable |
2016-05-09 |
|
Passed |
Stable |
2015-08-18 |
|
Failed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2015-08-18 |
|
Failed |
Stable |
2015-08-18 |
|
Passed |
Stable |
2016-04-20 |
|
Passed |
Stable |
2016-05-09 |
|
Not Applicable |
Stable |
2015-08-18 |
|
Passed |
Test suite overall result |
Failed |
TD.PD.VNDI.E1 VDM Identity - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must respond a VDM message |
PASSED |
Sending Discover Identity |
UUT must respond with NAK |
TD.PD.VNDI.E2 VDM SVIDs - Testing Upstream Port |
||
SKIPPED |
Checking Vendor Info |
Device does not respond to Discover Identity, test skipped |
TD.PD.VNDI.E3 VDM Modes - Testing Upstream Port |
||
SKIPPED |
Checking Vendor Info |
Device does not respond to Discover Identity, test skipped |
TD.PD.VNDI.E4 SOP* Handling - Testing Upstream Port |
||
PASSED |
Checking SOP* response |
SOP Capable declared as Yes |
PASSED |
Checking SOP* response |
UFP must not respond to SOP' |
PASSED |
Checking SOP* response |
UFP must not respond to SOP" |
PASSED |
Checking SOP* response |
SOP' Debug Capable declared as No |
PASSED |
Checking SOP* response |
SOP" Debug Capable declared as No |
TD.PD.VNDI.E6 Sink Capabilities - Testing Upstream Port |
||
PASSED |
Checking Sink PDOs |
Number of Sink PDOs declared as 4 |
PASSED |
Checking Sink PDO 1 |
Supply Type declared as Fixed |
PASSED |
Checking Sink PDO 1 |
Data Role Swap bit must be 0 |
PASSED |
Checking Sink PDO 1 |
USB Communication Capable declared as No |
PASSED |
Checking Sink PDO 1 |
Unconstrained Power declared as No |
FAILED |
Checking Sink PDO 1 |
Higher Capability declared as No, actual is Yes |
PASSED |
Checking Sink PDO 1 |
UUT is Sink only and must indicate PR_Swap as not supported |
PASSED |
Checking Sink PDO 1 |
Voltage declared as 5 V |
PASSED |
Checking Sink PDO 1 |
Operating Current declared as 500 mA |
PASSED |
Checking Sink PDO 2 |
Supply Type declared as Fixed |
PASSED |
Checking Sink PDO 2 |
Voltage declared as 14.8 V |
PASSED |
Checking Sink PDO 2 |
Operating Current declared as 1 A |
PASSED |
Checking Sink PDO 3 |
Supply Type declared as Fixed |
PASSED |
Checking Sink PDO 3 |
Voltage declared as 12 V |
PASSED |
Checking Sink PDO 3 |
Operating Current declared as 1 A |
PASSED |
Checking Sink PDO 4 |
Supply Type declared as Fixed |
PASSED |
Checking Sink PDO 4 |
Voltage declared as 15 V |
PASSED |
Checking Sink PDO 4 |
Operating Current declared as 1 A |
PASSED |
Checking Power |
Max consumed power shall be less than or equal to 16W |
TD.PD.VNDI.E8 Accepts PR_Swap as Sink - Testing Upstream Port |
||
SKIPPED |
Checking Vendor Info |
Device is not Dual Role, test skipped |
TD.PD.VNDI.E10 Requests PR_Swap as Sink - Testing Upstream Port |
||
SKIPPED |
Setting up device |
Device is not Dual Role, tests skipped |
TD.PD.VNDI.E11 DisplayPort Alt-Modes - Testing Upstream Port |
||
SKIPPED |
Setting up device |
Device does not respond to Discover Identity, test skipped |
Test suite overall result |
Passed |
TD.PD.C.E2 UFP Rp - Testing Upstream Port |
||
PASSED |
Applying 56k +10% to +5V on CC |
Vcc is 852 mV, must be in range 250 mV to 1.5 V |
PASSED |
Applying 56k -10% to +5V on CC |
Vcc is 868 mV, must be in range 250 mV to 1.5 V |
PASSED |
Applying 22k +10% to +5V on CC |
Vcc is 969 mV, must be in range 450 mV to 1.5 V |
PASSED |
Applying 22k -10% to +5V on CC |
Vcc is 1.07 V, must be in range 450 mV to 1.5 V |
PASSED |
Applying 10k +10% to +5V on CC |
Vcc is 1.61 V, must be in range 850 mV to 2.45 V |
PASSED |
Applying 10k -10% to +5V on CC |
Vcc is 1.82 V, must be in range 850 mV to 2.45 V |
Test suite overall result |
Failed |
TD.4.1.1 Initial Voltage - Testing Upstream Port |
||
PASSED |
Applying No Terms |
PUT SSRX and SSTX pins must be in USB Safe State |
PASSED |
Applying No Terms |
PUT must not source Vbus |
TD.4.3.1 Sink Connect Source - Testing Upstream Port |
||
PASSED |
Applying Source Terms |
PUT must advertise Rd termination for 100 ms |
PASSED |
Applying VBUS |
PUT must sink no more than 100 mA (actual was 47 mA) |
PASSED |
Applying VBUS |
PUT_R must not source Vconn (0 V measured) |
TD.4.3.2 Sink Connect DRP - Testing Upstream Port |
||
PASSED |
Switching Terms |
PUT must advertise Rd termination for 130 ms |
PASSED |
Applying VBUS |
PUT must sink no more than 100 mA (actual was 44 mA) |
PASSED |
Applying VBUS |
PUT_R must not source Vconn (0 V measured) |
PASSED |
Removing VBUS |
PUT must not source VBUS |
PASSED |
Removing VBUS |
PUT must not source Vconn (0 V measured) |
TD.4.3.3 Sink Connect Try.SRC DRP - Testing Upstream Port |
||
PASSED |
Switching Terms |
PUT must advertise Rd termination for 130 ms |
PASSED |
Applying VBUS |
PUT must sink no more than 100 mA (actual was 51 mA) |
PASSED |
Applying VBUS |
PUT_R must not source Vconn (0 V measured) |
PASSED |
Removing VBUS |
PUT must not source VBUS |
PASSED |
Removing VBUS |
PUT must not source Vconn (0 V measured) |
TD.4.3.4 Sink Connect Try.SNK DRP - Testing Upstream Port |
||
PASSED |
Switching Terms |
PUT must constantly advertise Rd termination |
PASSED |
Switching Terms |
PUT must advertise both Rd terminations |
PASSED |
Entering AttachWait.SRC |
PUT must constantly advertise Rd termination for 100 ms |
PASSED |
Entering Try.SNK |
PUT must constantly advertise Rd termination for 150 ms |
PASSED |
Entering TryWait.SRC |
PUT must constantly advertise Rd termination for 100 ms |
PASSED |
Entering TryWait.SRC |
PUT must advertise both Rd terminations |
PASSED |
Applying VBUS |
PUT must constantly advertise Rd termination |
PASSED |
Applying VBUS |
PUT must sink no more than 100 mA (actual was 32 mA) |
PASSED |
Applying VBUS |
PUT_R must not source Vconn (0 V measured) |
PASSED |
Removing VBUS |
PUT must not source VBUS |
PASSED |
Removing VBUS |
PUT must not source Vconn (0 V measured) |
TD.4.3.5 Sink Connect SNKAS - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT is not a Vconn Powered Accessory, test skipped |
TD.4.3.6 Sink Connect Accessories - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT does not support Audio Accessory, test skipped |
TD.4.10.1 Sink Power Sub-States - Testing Upstream Port |
||
PASSED |
Applying Rp-USB |
PUT must sink no more than 500 mA (actual was 44 mA) |
PASSED |
Applying Rp-1.5A |
PUT must sink no more than 1.5 A before 10 ms (actual maximum was 50 mA) |
PASSED |
Applying Rp-1.5A |
PUT must sink no more than 1.5 A after 20 ms (actual maximum was 423 mA) |
FAILED |
Applying Rp-USB |
PUT must sink no more than 500 mA after 60 ms (actual maximum was 688 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A before 10 ms (actual maximum was 50 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A after 20 ms (actual maximum was 50 mA) |
PASSED |
Applying Rp-1.5A |
PUT must sink no more than 1.5 A after 60 ms (actual maximum was 849 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A before 10 ms (actual maximum was 51 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A after 20 ms (actual maximum was 54 mA) |
PASSED |
Applying Rp-USB |
PUT must sink no more than 500 mA after 60 ms (actual maximum was 53 mA) |
PASSED |
Applying Rp-1.5A |
PUT must sink no more than 1.5 A before 10 ms (actual maximum was 52 mA) |
PASSED |
Applying Rp-1.5A |
PUT must sink no more than 1.5 A after 20 ms (actual maximum was 421 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A before 10 ms (actual maximum was 50 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3 A after 20 ms (actual maximum was 261 mA) |
TD.4.10.2 Sink Power Precedence - Testing Upstream Port |
||
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3000 mA (actual was 46 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 3000 mA (actual was 48 mA) |
PASSED |
Offering 1.5 A PDO with Rp-1.5A |
PUT must sink no more than 1500 mA (actual was 46 mA) |
PASSED |
Applying Rp-3.0A |
PUT must sink no more than 1500 mA (actual was 45 mA) |
PASSED |
Sending Hard Reset |
PUT must sink no more than 500 mA (actual was 48 mA) |
TD.4.10.3 Sink Suspend - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT is not a USB Device, test skipped |
TD.4.10.4 Sink Power Role Swap - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT does not support Power Role Swap as Sink, test skipped |
TD.4.10.5 Sink Vconn Swap - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT does not support Vconn Swap as Sink, test skipped |
TD.4.10.6 Sink Alternate Mode - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT is not an Alternate Mode Adapter, test skipped |
TD.4.11.1 Data Role Swap - Testing Upstream Port |
||
SKIPPED |
Switching PUT to DFP |
PUT does not accept Data Role Swap as UFP, test skipped |
TD.4.11.2 Sink Dead Battery - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT does not have a battery, test skipped |
TD.4.12.2 Hub Port Types - Testing Upstream Port |
||
SKIPPED |
Setting up device |
PUT does not belong to a USB 3.1 Hub, test skipped |
Test suite overall result |
Passed |
TD.PD.PHY.E1 BIST Test Data - Testing Upstream Port |
||
PASSED |
Sending 1000 BIST Data |
UUT must respond to all BIST Data packets (1000 answered) |
PASSED |
Sending 1 Wrong BIST Data |
UUT must not respond |
PASSED |
Sending 10 BIST Data |
UUT must respond to all BIST Data packets (10 answered) |
TD.PD.PHY.E2 BIST Receiver Mode - Testing Upstream Port |
||
SKIPPED |
Entering BIST Receiver |
UUT does not support BIST Received mode, test skipped |
TD.PD.PHY.E3 BIST Transmitter Mode - Testing Upstream Port |
||
SKIPPED |
Entering BIST Transmitter |
UUT does not support BIST Transmitter mode, test skipped |
TD.PD.PHY.E4 Transmitter Bit Rate Drift - Testing Upstream Port |
||
INFO |
Measuring Bitrate |
Measured values: Min 299'872 b/s, Ref 299'895 b/s, Max 299'917 b/s |
PASSED |
Measuring Bitrate |
Minimum bitrate must be within 270-330 kb/s |
PASSED |
Measuring Bitrate |
Minimum bitrate must be within -0.25 % of reference bitrate (-0.008 %) |
PASSED |
Measuring Bitrate |
Maximum bitrate must be within 270-330 kb/s |
PASSED |
Measuring Bitrate |
Maximum bitrate must be within +0.25 % of reference bitrate (+0.007 %) |
TD.PD.PHY.E5 Transmitter Collision Avoidance - Testing Upstream Port |
||
PASSED |
Sending BIST Test Data |
UUT must not send GoodCrc |
PASSED |
Sending BIST Test Data |
UUT must not send GoodCrc |
TD.PD.PHY.E6 Receiver Swing Tolerance - Testing Upstream Port |
||
PASSED |
Setting Tx Amplitude to 1.2 V |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
PASSED |
Setting Tx Amplitude to 1.05 V |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
TD.PD.PHY.E7 Receiver Bit Rate Tolerance - Testing Upstream Port |
||
PASSED |
Setting Tx Bit Rate to 330 kb/s |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
PASSED |
Setting Tx Bit Rate to 270 kb/s |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
TD.PD.PHY.E8 Receiver Bit Rate Deviation Tolerance - Testing Upstream Port |
||
PASSED |
Deviating Tx Bit Rate to -0.25% |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
PASSED |
Deviating Tx Bit Rate to +0.25% |
UUT must respond to all 1000 BIST Data packets (1000 answered) |
TD.PD.PHY.E9 Valid SOP Framing - Testing Upstream Port |
||
PASSED |
Sending Perfect BIST Data |
UUT must respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 0, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 1, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 2, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 3, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 4, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 0, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 1, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 2, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 3, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 4, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 0, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 1, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 2, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 3, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 4, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 0, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 1, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 2, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 3, UUT should respond |
INFO |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 4, UUT should respond |
TD.PD.PHY.E10 Invalid SOP Framing - Testing Upstream Port |
||
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 1, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 2 and 3, UUT must not respond |
TD.PD.PHY.E11 Valid SOP' Framing - Testing Upstream Port |
||
PASSED |
Sending Perfect BIST Data |
UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 4, UUT must not respond |
TD.PD.PHY.E12 Invalid SOP' Framing - Testing Upstream Port |
||
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 1, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 2 and 3, UUT must not respond |
TD.PD.PHY.E13 Valid SOP" Framing - Testing Upstream Port |
||
PASSED |
Sending Perfect BIST Data |
UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 0, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 1, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 2, bit 4, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 0, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 1, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 2, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 3, UUT must not respond |
PASSED |
Sending 200 Valid BIST Data |
Bitflip in framing symbol 3, bit 4, UUT must not respond |
TD.PD.PHY.E14 Invalid SOP" Framing - Testing Upstream Port |
||
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 1, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 0 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 2, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 1 and 3, UUT must not respond |
PASSED |
Sending 60 Wrong BIST Data |
Bitflip in framing symbols 2 and 3, UUT must not respond |
TD.PD.PHY.E15 Valid SOP'/" Debug Framings - Testing Upstream Port |
||
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 0, bit 0, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 0, bit 1, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 0, bit 2, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 0, bit 3, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 0, bit 4, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 1, bit 0, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 1, bit 1, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 1, bit 2, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 1, bit 3, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 1, bit 4, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 2, bit 0, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 2, bit 1, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 2, bit 2, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 2, bit 3, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 2, bit 4, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 3, bit 0, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 3, bit 1, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 3, bit 2, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 3, bit 3, UUT must not respond |
PASSED |
Sending SOP'_Debug BIST Data |
Bitflip in framing symbol 3, bit 4, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 0, bit 0, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 0, bit 1, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 0, bit 2, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 0, bit 3, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 0, bit 4, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 1, bit 0, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 1, bit 1, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 1, bit 2, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 1, bit 3, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 1, bit 4, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 2, bit 0, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 2, bit 1, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 2, bit 2, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 2, bit 3, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 2, bit 4, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 3, bit 0, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 3, bit 1, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 3, bit 2, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 3, bit 3, UUT must not respond |
PASSED |
Sending SOP"_Debug BIST Data |
Bitflip in framing symbol 3, bit 4, UUT must not respond |
TD.PD.PHY.E16 Valid Hard Reset Framing - Testing Upstream Port |
||
PASSED |
Sending Perfect Hard Reset |
UUT must process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 0, bit 0, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 0, bit 1, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 0, bit 2, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 0, bit 3, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 0, bit 4, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 1, bit 0, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 1, bit 1, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 1, bit 2, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 1, bit 3, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 1, bit 4, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 2, bit 0, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 2, bit 1, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 2, bit 2, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 2, bit 3, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 2, bit 4, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 3, bit 0, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 3, bit 1, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 3, bit 2, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 3, bit 3, UUT should process Hard Reset |
PASSED |
Sending 20 Valid Hard Reset |
Bitflip in framing symbol 3, bit 4, UUT should process Hard Reset |
TD.PD.PHY.E17 Invalid Hard Reset Framing - Testing Upstream Port |
||
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 0 and 1, UUT must ignore Hard Reset |
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 0 and 2, UUT must ignore Hard Reset |
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 0 and 3, UUT must ignore Hard Reset |
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 1 and 2, UUT must ignore Hard Reset |
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 1 and 3, UUT must ignore Hard Reset |
PASSED |
Sending 6 Invalid Hard Reset |
Bitflip in framing symbols 2 and 3, UUT must ignore Hard Reset |
TD.PD.PHY.E18 Valid Cable Reset Framing - Testing Upstream Port |
||
PASSED |
Sending Perfect Cable Reset |
UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 0, bit 0, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 0, bit 1, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 0, bit 2, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 0, bit 3, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 0, bit 4, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 1, bit 0, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 1, bit 1, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 1, bit 2, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 1, bit 3, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 1, bit 4, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 2, bit 0, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 2, bit 1, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 2, bit 2, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 2, bit 3, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 2, bit 4, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 3, bit 0, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 3, bit 1, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 3, bit 2, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 3, bit 3, UUT must ignore Cable Reset |
PASSED |
Sending 20 Valid Cable Reset |
Bitflip in framing symbol 3, bit 4, UUT must ignore Cable Reset |
TD.PD.PHY.E19 Invalid Cable Reset Framing - Testing Upstream Port |
||
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 0 and 1, UUT must ignore Cable Reset |
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 0 and 2, UUT must ignore Cable Reset |
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 0 and 3, UUT must ignore Cable Reset |
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 1 and 2, UUT must ignore Cable Reset |
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 1 and 3, UUT must ignore Cable Reset |
PASSED |
Sending 6 Invalid Cable Reset |
Bitflip in framing symbols 2 and 3, UUT must ignore Cable Reset |
TD.PD.PHY.E20 EOP Framing - Testing Upstream Port |
||
PASSED |
Sending Correct BIST Data |
UUT must respond |
PASSED |
Sending 5 Wrong BIST Data |
Bitflip in EOP symbol, bit 0, UUT must not respond |
PASSED |
Sending 5 Wrong BIST Data |
Bitflip in EOP symbol, bit 1, UUT must not respond |
PASSED |
Sending 5 Wrong BIST Data |
Bitflip in EOP symbol, bit 2, UUT must not respond |
PASSED |
Sending 5 Wrong BIST Data |
Bitflip in EOP symbol, bit 3, UUT must not respond |
PASSED |
Sending 5 Wrong BIST Data |
Bitflip in EOP symbol, bit 4, UUT must not respond |
PASSED |
Sending 33 Short BIST Data |
UUT must not respond to BIST Data packets (0 answered) |
TD.PD.PHY.E21 Preamble - Testing Upstream Port |
||
PASSED |
Sending 10 BIST Data |
UUT must respond to all BIST Data packets (10 answered) |
PASSED |
Sending 10 63-bit Preamble BIST Data |
UUT must respond to all BIST Data packets (10 answered) |
INFO |
Sending 210 Variable Preamble BIST Data |
UUT answered 210 BIST Data packets |
Test suite overall result |
Passed |
TD.PD.LL.E2 Retransmission - Testing Upstream Port |
||
PASSED |
Checking Retransmission |
UUT must retransmit first message one time within 900 us to 1175 us (retransmitted 1 time) |
PASSED |
Checking Retransmission |
UUT must not send SoftReset one time (sent 0 times) |
PASSED |
Checking Retransmission |
UUT must not send HardReset one time (sent 0 times) |
TD.PD.LL.E3 Soft Reset Usage - Testing Upstream Port |
||
PASSED |
Checking Soft Reset |
UUT must retransmit first message 3 times (retransmitted 3 times) |
PASSED |
Checking Soft Reset |
UUT must send SoftReset one time (sent 1 time) |
PASSED |
Checking Soft Reset |
UUT must not send HardReset (sent 0 times) |
PASSED |
Checking Soft Reset |
Soft Reset procedure must complete correctly |
TD.PD.LL.E4 Hard Reset Usage - Testing Upstream Port |
||
PASSED |
Checking Hard Reset |
UUT must retransmit first message 3 times (retransmitted 3 times) |
PASSED |
Checking Hard Reset |
UUT must send SoftReset 4 times (sent 4 times) |
PASSED |
Checking Hard Reset |
UUT must send HardReset one time (sent 1 time) |
PASSED |
Checking Hard Reset |
Hard Reset procedure must complete correctly |
TD.PD.LL.E5 Soft Reset - Testing Upstream Port |
||
PASSED |
Negotiating contract |
UUT must send Accept after receiving SoftReset |
PASSED |
Negotiating contract |
UUT must not send SoftReset (sent 0 times) |
PASSED |
Negotiating contract |
UUT must not send HardReset (sent 0 times) |
TD.PD.LL.E6 Ping - Testing Upstream Port |
||
PASSED |
Sending 50 Ping |
UUT must send answer all Ping packets + (100 answered) |
Test suite overall result |
Passed |
Test suite overall result |
Failed |
TD.PD.SNK.E1 SinkWaitCapTimer Deadline - Testing Upstream Port |
||
FAILED |
Sending Source Capabilities |
Source Capabilities message NOT accepted |
TD.PD.SNK.E2 SinkWaitCapTimer Timeout - Testing Upstream Port |
||
FAILED |
Waiting for HardReset |
SinkWaitCapTimer too long, HardReset not detected after 620 ms |
TD.PD.SNK.E3 Request Sent Timely - Testing Upstream Port |
||
PASSED |
Waiting for Request |
Request message received timely |
TD.PD.SNK.E4 Request Fields Checks - Testing Upstream Port |
||
PASSED |
Checking message Header |
Number of Data Objects shall be 001b |
PASSED |
Checking message Header |
message ID shall be 0 |
PASSED |
Checking message Header |
Port Power Role shall be 0b |
PASSED |
Checking message Header |
Port Data Role shall be 0b |
PASSED |
Checking message Header |
Specification Revision shall be equal or lower than Specification Revision in Source_Capabilities Message |
PASSED |
Checking message Header |
Specification Revision is 01b |
PASSED |
Checking message Header |
Bit 4 shall be 0 |
PASSED |
Checking message Header |
Bit 15 shall be 0 |
PASSED |
Checking Request Data Object |
Object Position shall be 1 |
PASSED |
Checking Request Data Object |
Operating current shall be less than or equal to offered current |
FAILED |
Checking Request Data Object |
Maximum current shall be larger than or equal to operating current when giveback is 0 |
PASSED |
Checking Request Data Object |
Bit 31 of the request object shall be 0 |
PASSED |
Checking Request Data Object |
Bits 22..20 of the request object shall be 000b |
PASSED |
Checking Request Data Object |
Bit 23 of the request object shall be 0 for PD 2.0 |
PASSED |
Checking message Header |
Number of Data Objects shall be 001b |
PASSED |
Checking message Header |
message ID shall be 0 |
PASSED |
Checking message Header |
Port Power Role shall be 0b |
PASSED |
Checking message Header |
Port Data Role shall be 0b |
PASSED |
Checking message Header |
Specification Revision shall be equal or lower than Specification Revision in Source_Capabilities Message |
PASSED |
Checking message Header |
Specification Revision is 01b |
PASSED |
Checking message Header |
Bit 4 shall be 0 |
PASSED |
Checking message Header |
Bit 15 shall be 0 |
PASSED |
Checking Request Data Object |
Object Position shall be 1 |
PASSED |
Checking Request Data Object |
Operating current shall be less than or equal to offered current |
FAILED |
Checking Request Data Object |
Maximum current shall be larger than or equal to operating current when giveback is 0 |
PASSED |
Checking Request Data Object |
Bit 31 of the request object shall be 0 |
PASSED |
Checking Request Data Object |
Bits 22..20 of the request object shall be 000b |
PASSED |
Checking Request Data Object |
Bit 23 of the request object shall be 0 for PD 2.0 |
PASSED |
Checking message Header |
Number of Data Objects shall be 001b |
PASSED |
Checking message Header |
message ID shall be 0 |
PASSED |
Checking message Header |
Port Power Role shall be 0b |
PASSED |
Checking message Header |
Port Data Role shall be 0b |
PASSED |
Checking message Header |
Specification Revision shall be equal or lower than Specification Revision in Source_Capabilities Message |
PASSED |
Checking message Header |
Specification Revision is 01b |
PASSED |
Checking message Header |
Bit 4 shall be 0 |
PASSED |
Checking message Header |
Bit 15 shall be 0 |
PASSED |
Checking Request Data Object |
Object Position shall be 1 |
PASSED |
Checking Request Data Object |
Operating current shall be less than or equal to offered current |
FAILED |
Checking Request Data Object |
Maximum current shall be larger than or equal to operating current when giveback is 0 |
PASSED |
Checking Request Data Object |
Bit 31 of the request object shall be 0 |
PASSED |
Checking Request Data Object |
Bits 22..20 of the request object shall be 000b |
PASSED |
Checking Request Data Object |
Bit 23 of the request object shall be 0 for PD 2.0 |
TD.PD.SNK.E5 SenderResponseTimer Deadline - Accept - Testing Upstream Port |
||
PASSED |
Sending Accept |
GoodCRC of Accept message received |
TD.PD.SNK.E6 SenderResponseTimer Timeout - Accept - Testing Upstream Port |
||
PASSED |
Waiting for HardReset |
SenderResponseTimer is valid (actual 27.4 ms) |
TD.PD.SNK.E7 PSTransitionTimer Deadline - Testing Upstream Port |
||
PASSED |
Sending PS_RDY |
GoodCRC of PS_RDY message received |
TD.PD.SNK.E8 PSTransitionTimer Timeout - Testing Upstream Port |
||
PASSED |
Waiting for HardReset |
PSTransitionTimer is valid (actual 487 ms) |
TD.PD.SNK.E9 GetSinkCap in Place of Accept - Testing Upstream Port |
||
PASSED |
Waiting for Request |
Recovered successfully after Soft Reset |
TD.PD.SNK.E10 GetSinkCap in Place of PS_RDY - Testing Upstream Port |
||
FAILED |
Waiting for Soft Reset/Hard Reset |
The latest spec requires UUT send HardReset within 15 ms |
PASSED |
Waiting for Request |
Recovered successfully after Soft Reset |
TD.PD.SNK.E12 Compatibility with PD3 Source - Testing Upstream Port |
||
PASSED |
Checking Request Data Object |
Object Position shall be 1 or 2 |
Test suite overall result |
Failed |
TD.PD.VDMU.E1 Discover Identity Response - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
UUT did not respond with ACK, test skipped |
TD.PD.VDMU.E2 Discover SVIDs Response - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
Modal Operation not supported, test skipped |
TD.PD.VDMU.E3 Discover Modes Response - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
Modal Operation not supported, test skipped |
TD.PD.VDMU.E4 Enter Mode Response - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
Modal Operation not supported, test skipped |
TD.PD.VDMU.E5 Exit Mode Response - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
Modal Operation not supported, test skipped |
TD.PD.VDMU.E6 Discover Identity Response Time - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must start responding within 15 ms (answered in 999 µs) |
PASSED |
Sending Discover Identity |
UUT must respond with ACK or NAK |
TD.PD.VDMU.E7 Discover SVIDs Response Time - Testing Upstream Port |
||
PASSED |
Sending Discover SVIDs |
UUT must start responding within 15 ms (answered in 154 µs) |
FAILED |
Checking Discover SVIDs Response |
Modal Operation is not supported, UUT must respond with NAK |
TD.PD.VDMU.E8 Discover Modes Response Time - Testing Upstream Port |
||
PASSED |
Sending Discover Modes |
UUT must start responding within 15 ms (answered in 139 µs) |
PASSED |
Sending Discover Modes |
Modal Operation is not supported, UUT must respond with NAK |
TD.PD.VDMU.E9 Enter/Exit Mode Response Time - Testing Upstream Port |
||
PASSED |
Sending Enter Mode |
UUT must start responding within 15 ms (answered in 157 µs) |
PASSED |
Sending Enter Mode |
UUT must respond with ACK or NAK to Enter Mode < 7 |
PASSED |
Sending Enter Mode |
UUT must respond with NAK to Enter Mode 7 |
PASSED |
Sending Exit Mode |
UUT must start responding within 15 ms (answered in 163 µs) |
PASSED |
Sending Exit Mode |
UUT must respond same as Enter Mode < 7 (NAK) |
PASSED |
Sending Exit Mode |
UUT must respond with ACK or NAK to Exit Mode 7 |
TD.PD.VDMU.E10 Discover Identity Wrong SVID - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must not respond or respond NAK within 15 ms (answered in 1.01 ms) |
PASSED |
Sending Discover Identity |
UUT response SVID must be set to 0xEEEE |
TD.PD.VDMU.E11 Discover SVIDs Wrong SVID - Testing Upstream Port |
||
PASSED |
Sending Discover SVIDs |
UUT must not respond or respond NAK within 15 ms (answered in 999 µs) |
PASSED |
Sending Discover SVIDs |
UUT response SVID must be set to 0xEEEE |
TD.PD.VDMU.E12 Discover Modes Wrong SVID - Testing Upstream Port |
||
PASSED |
Sending Discover Modes |
UUT must start responding within 15 ms (answered in 121 µs) |
PASSED |
Sending Discover Modes |
UUT must respond with NAK |
PASSED |
Sending Discover Modes |
UUT response SVID must be set to 0xEEEE |
TD.PD.VDMU.E13 Enter Mode Wrong SVID - Testing Upstream Port |
||
PASSED |
Sending Enter Mode |
UUT must start responding within 15 ms (answered in 119 µs) |
PASSED |
Sending Enter Mode |
UUT must respond with NAK |
PASSED |
Sending Enter Mode |
UUT response SVID must be set to 0xEEEE |
PASSED |
Sending Enter Mode |
UUT response Object Position must be 1 |
TD.PD.VDMU.E14 Exit Mode Wrong SVID - Testing Upstream Port |
||
PASSED |
Sending Exit Mode |
UUT must start responding within 15 ms (answered in 125 µs) |
PASSED |
Sending Exit Mode |
UUT must respond with NAK |
PASSED |
Sending Exit Mode |
UUT response SVID must be set to 0xEEEE |
PASSED |
Sending Exit Mode |
UUT response Object Position must be 1 |
TD.PD.VDMU.E15 Applicability - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must start responding within 15 ms (answered in 1.02 ms) |
PASSED |
Sending Discover Identity |
UUT must respond with ACK or NAK |
PASSED |
Sending Discover SVIDs |
UUT must start responding within 15 ms (answered in 150 µs) |
FAILED |
Sending Discover SVIDs |
Modal Operation is not supported, UUT must respond with NAK |
PASSED |
Sending Discover Modes |
UUT must start responding within 15 ms (answered in 143 µs) |
PASSED |
Sending Discover Modes |
Modal Operation is not supported, UUT must respond with NAK |
PASSED |
Sending Wrong Enter Mode |
UUT must start responding within 15 ms (answered in 127 µs) |
PASSED |
Sending Wrong Enter Mode |
UUT must respond with NAK |
PASSED |
Sending Wrong Exit Mode |
UUT must start responding within 15 ms (answered in 133 µs) |
PASSED |
Sending Wrong Exit Mode |
UUT must respond with NAK |
TD.PD.VDMU.E16 Interruption by PD Command - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must not send Soft Reset or Hard Reset |
PASSED |
Sending Discover SVIDs |
UUT must not send Soft Reset or Hard Reset |
PASSED |
Sending Discover Modes |
UUT must not send Soft Reset or Hard Reset |
PASSED |
Sending Wrong Enter Mode |
UUT must not send Soft Reset or Hard Reset |
PASSED |
Sending Wrong Exit Mode |
UUT must not send Soft Reset or Hard Reset |
TD.PD.VDMU.E17 Interruption by VDM Command - Testing Upstream Port |
||
PASSED |
Sending Discover Identity |
UUT must start responding within 15 ms (answered in 1.01 ms) |
PASSED |
Sending Discover Identity |
UUT must only respond to second request |
PASSED |
Sending Discover SVIDs |
UUT must start responding within 15 ms (answered in 1.02 ms) |
PASSED |
Sending Discover SVIDs |
UUT must only respond to second request |
PASSED |
Sending Discover Modes |
UUT must start responding within 15 ms (answered in 1.01 ms) |
PASSED |
Sending Discover Modes |
UUT must only respond to second request |
PASSED |
Sending Wrong Enter Mode |
UUT must start responding within 15 ms (answered in 1.01 ms) |
PASSED |
Sending Wrong Enter Mode |
UUT must only respond to second request |
PASSED |
Sending Wrong Exit Mode |
UUT must start responding within 15 ms (answered in 1.01 ms) |
PASSED |
Sending Wrong Exit Mode |
UUT must only respond to second request |
TD.PD.VDMU.E18 Data Role Swap Hard Reset - Testing Upstream Port |
||
SKIPPED |
Sending Discover Identity |
UUT does not support Modal Operation, test skipped |
Test suite overall result |
Passed |