eUSB High Speed Repeater Signal Quality Test
Results for p4
For details on test setup, methodology, and performance criteria, please consult the signal quality test description at the USB-IF Compliance Program web page.
Required Tests
- Overall result: pass!
- Signal eye:
eye passes
*** last transition exception invoked ***
- EOP width: 12.92 bits
*** EOP width failure! *** (minimum 7.50 bits, maximum 12.50 bits)
*** waiver granted ***
- Measured signaling rate: 479.9901 MHz
signal rate passes
- Edge Monotonicity: 0 mV
Monotonic Edge passes
- Rising Edge Rate: 1101.00 V/us (581.29 ps equivalent risetime)
passes
- Falling Edge Rate: 1114.81 V/us (574.09 ps equivalent falltime)
passes
Additional Information
- Consecutive jitter range: -38.229 ps to 31.888 ps, RMS jitter 15.608 ps
- Paired JK jitter range: -36.098 ps to 43.301 ps, RMS jitter 10.372 ps
- Paired KJ jitter range: -35.896 ps to 28.725 ps, RMS jitter 9.563 ps
- Margin Above eye: 72.4000 mV
- Margin Below eye: 64.0000 mV
- Maximum Voltage: 462.0000 mV
- Margin Below Top: 163.0000 mV
- Minimum Voltage: -462.0000 mV
- Margin Above Bottom: 163.0000 mV
- Margin_Top_Left_Up: 69.4237 mV
- Margin_Bottom_Left_Down: 61.9937 mV
- Min_Peak_Peak_Center: 767.5511 mV
SignalData and Eye


Tracking Information
- Oscilloscope sample rate: 12.500 GS/s
- Data file: C:\Users\EEPA\Desktop\USBET2\p4.wfm
- Test version: 2.20.00E
- Analysis performed: Wed May 6 17:52:14 2026