;// FILE:   F2805x_DCSM_Z2_ZoneSelectBlock._asm
;//
;// TITLE:  F2805x Dual Code Security Module Zone 2 Zone Select Block Values.
;//
;// DESCRIPTION:
;//
;//         This file is used to specify Z2 DCSM OTP and zone select
;//         values to program into the Zone 2 zone select locations in OTP
;//         Value depends on Linkpointer).
;//
;//         In addition, the 60 reserved values after the zone select block
;//         are all programmed to 0x0000 as well.
;//
;//###########################################################################
;// $TI Release:  $
;// $Release Date:  $
;// $Copyright:
;// Copyright (C) 2012-2024 Texas Instruments Incorporated - http://www.ti.com/
;//
;// Redistribution and use in source and binary forms, with or without 
;// modification, are permitted provided that the following conditions 
;// are met:
;// 
;//   Redistributions of source code must retain the above copyright 
;//   notice, this list of conditions and the following disclaimer.
;// 
;//   Redistributions in binary form must reproduce the above copyright
;//   notice, this list of conditions and the following disclaimer in the 
;//   documentation and/or other materials provided with the   
;//   distribution.
;// 
;//   Neither the name of Texas Instruments Incorporated nor the names of
;//   its contributors may be used to endorse or promote products derived
;//   from this software without specific prior written permission.
;// 
;// THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 
;// "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT 
;// LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
;// A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT 
;// OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, 
;// SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT 
;// LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
;// DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
;// THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
;// (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE 
;// OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
;// $
;//###########################################################################


; !!IMPORTANT!!: The "dcsm_otp_z2" section contains the Z2 LINKPOINTER which
; determines the location of the Z2 Zone Select block.  If the LINKPOINTER
; is changed, then the "dcsm_zsel_z2" section in the F2805x.cmd command linker
; file must also change to an address decoded from the value specified
; in the Z2-LINKPOINTER location.

; The "dcsm_zsel_z2" section contains the actual Z2 Zone Select Block values
; that will be linked and programmed into to the DCSM Z2 OTP Zone Select block
; in OTP. These values must be known in order to unlock the CSM module. All
; 0xFFFFFFFF's (erased) is the default value for the password locations (PWL).

; It is recommended that all values be left as 0xFFFFFFFF during code
; development.  Values of 0xFFFFFFFF do not activate code security and dummy
; reads of the Z2 DCSM PWL registers is all that is required to unlock the CSM.
; When code development is complete, modify values to activate the
; code security module.

      .sect "dcsm_otp_z2"

      .long 0xFFFFFFFF     ;Z2-LINKPOINTER
      .long 0xFFFFFFFF     ;OTPSECLOCK

      .sect "dcsm_zsel_z2"

      .long 0xFFFFFFFF      ;Z2-EXEONLYRAM
      .long 0xFFFFFFFF      ;Z2-EXEONLYSECT
      .long 0xFFFFFFFF      ;Z2-GRABRAM
      .long 0xFFFFFFFF      ;Z2-GRABSECT

      .long 0xFFFFFFFF      ;Z2-CSMPSWD0 (LSW of 128-bit password)
      .long 0xFFFFFFFF      ;Z2-CSMPSWD1
      .long 0xFFFFFFFF      ;Z2-CSMPSWD2
      .long 0xFFFFFFFF      ;Z2-CSMPSWD3 (MSW of 128-bit password)

;----------------------------------------------------------------------

; For code security operation,after development has completed, prior to
; production, all other zone select block locations should be programmed
; to 0x0000 for maximum security.
; If the first zone select block at offset 0x10 is used, the section
;"dcsm_rsvd_z2" can be used to program these locations to 0x0000.
; This code is commented out for development.

;        .sect "dcsm_rsvd_z2"
;        .loop (1e0h)
;              .int 0x0000
;        .endloop

;//
;// End of file.
;//