Date and time |
Wednesday, 18 December 2024 16:35:24 GMT+8 |
Vendor |
TI |
Product |
TPS659xx |
Product revision |
1 |
Test ID |
0 |
Component Under Test |
1 |
Port Label |
1 |
Generator used |
Ellisys USB Explorer 350 (EX350-62440) |
Analyzer used |
Ellisys USB Explorer 350 (EX350-62921) |
Software version |
Report generated with version 3.1.9109 |
Overall result |
Failed |
Test status |
Last updated on |
||
Failed |
|||
Failed |
RC |
2017-11-13 |
Test suite overall result |
Failed |
TD.4.5.4 DRP Connect DRP - Testing Dual Role Port (trace) |
||
INFO |
Starting Subtest 1 |
Using tDrp = 50 ms, dcSRC.DRP = 30% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 15 mA) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 2 |
Using tDrp = 75 ms, dcSRC.DRP = 30% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.79 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 3 |
Using tDrp = 100 ms, dcSRC.DRP = 30% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.79 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 4 |
Using tDrp = 50 ms, dcSRC.DRP = 50% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 19 mA) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 5 |
Using tDrp = 75 ms, dcSRC.DRP = 50% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 6 |
Using tDrp = 100 ms, dcSRC.DRP = 50% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 7 |
Using tDrp = 50 ms, dcSRC.DRP = 70% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 18 mA) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.79 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 8 |
Using tDrp = 75 ms, dcSRC.DRP = 70% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |
INFO |
Starting Subtest 9 |
Using tDrp = 100 ms, dcSRC.DRP = 70% |
INFO |
Applying Source Terms |
Rd is present in step 2 for longer than tCCDebounce, going to step 8 |
PASSED |
Applying Source Terms |
PUT must sink no more than 100 mA (actual was 0 A) |
FAILED |
Applying Source Terms |
PUT_R must not source Vconn (4.78 V measured) |
PASSED |
Applying Low VBUS as Source |
Put must maintain Rd |
FAILED |
Applying Sink Terms |
PUT must present Rp |
PASSED |
Applying Sink Terms |
PUT must not source Vbus |
FAILED |
Applying Sink Terms |
PUT must source Vbus after Vbus has entered vSafe0V and before tVbusON expires |