Chemistry ID selection tool, rev=2.54 Configuration used in present fit: ProcessingType=2 NumCellSeries=1 ElapsedTimeColumn=0 VoltageColumn=1 CurrentColumn=2 TemperatureColumn=3 Best chemical ID : 457 Best chemical ID max. deviation, % : 8.25 Summary of all IDs with max. DOD deviation below 15% Chem ID max DOD error, % Max R deviation, ratio 457 8.25 3.98 448 9.6 -1274.47 4124 9.64 1.28 4171 9.7 1.93 425 9.97 1.58 464 10.12 -543.63 400 10.17 -40.58 4184 10.24 4.87 4189 10.29 5.85 445 10.57 1.3 4188 10.74 2.58 485 11.07 0.06 487 11.07 0.06 4160 11.12 -274.26 406 11.25 0.98 4139 11.37 -390.05 449 11.38 -1822.06 4167 11.46 -90.32 462 11.5 -561.13 4175 11.59 2.47 482 11.7 0.13 424 11.91 0.84 4172 12.08 1.87 426 12.12 0.82 4149 12.25 -471.71 4110 12.26 -259.86 444 12.27 -330.07 478 12.28 0.05 447 12.33 -34.47 4106 12.37 0.57 2160 12.38 -171.9 4180 12.43 2.24 405 12.46 0.89 6105 12.47 -325.67 416 12.68 -520.19 401 12.68 -354.43 4134 12.74 0.96 422 12.76 0.53 488 12.86 0.67 421 12.94 0.08 4166 13.19 0.71 461 13.2 2.29 414 13.22 -1006.26 446 13.28 0.33 4135 13.43 -623.6 423 13.47 1.14 402 13.47 0.61 491 13.69 -677.25 436 13.72 -616.37 4182 13.75 3.83 481 13.75 0.1 4111 13.76 -80.75 410 13.77 -19243.72 435 13.79 -595.16 4159 13.84 -179.97 437 13.87 -517.27 6110 13.91 -281.4 429 14 0.66 4174 14.08 1.55 4150 14.11 1.54 417 14.13 -567.06 4190 14.3 1.32 465 14.49 -429.09 4144 14.54 2.36 432 14.6 -989.14 4179 14.74 20.99 Max. deviations for best ID is within recommended range. Chosen best chemical ID is suitable for programming the gauge. Selection of best generic ID for ROM based devices like bq274xx Device / Family #1 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 312 bq27421-G1B: 4.3V LiCoO2 17.04 354 bq27411-G1C: 4.35V LiCoO2 35.87 3142 bq27421-G1D: 4.4V LiCoO2 41.25 128 bq27421-G1A: 4.2V LiCoO2 51.05 Best generic ID 312 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #2 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 354 bq27621: (ALT_CHEM2) 4.35V LiCoO2 35.87 1202 bq27621: (default) 4.2V LiCoO2 35.96 1210 bq27621: (ALT_CHEM1) 4.3V LiCoO2 39.71 Best generic ID 354 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #3 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3230 bq27426: (default) 4.35V LiCoO2 33.49 1202 bq27426: (ALT_CHEM1) 4.2V LiCoO2 35.96 3142 bq27426: (ALT-CHEM2) 4.4V LiCoO2 41.25 Best generic ID 3230 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 13.5360163712246 Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 13.5360163712246 Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 13.5360163712246