Chemistry ID selection tool, rev=2.42 Configuration used in present fit: ProcessingType=2 NumCellSeries=1 ElapsedTimeColumn=0 VoltageColumn=2 CurrentColumn=3 TemperatureColumn=1 Best chemical ID : 2037 Best chemical ID max. deviation, % : 1.04 Summary of all IDs with max. DOD deviation below 3% Chem ID max DOD error, % Max R deviation, ratio 2037 1.04 0.33 2040 1.24 0.38 284 1.29 0.6 2056 1.3 1.04 278 1.31 0.58 1273 1.34 0.59 2042 1.35 0.69 2099 1.37 0.16 2034 1.38 1.14 2036 1.4 1.14 281 1.41 0.45 285 1.42 0.45 2083 1.45 0.41 1737 1.47 0.71 210 1.49 0.6 2076 1.49 0.26 2019 1.49 0.47 2097 1.51 0.35 2154 1.51 0.53 2043 1.52 0.35 238 1.52 0.31 232 1.53 0.38 2052 1.58 0.59 2012 1.63 0.78 2128 1.64 0.57 3166 1.66 0.58 2061 1.73 1.11 2004 1.79 0.33 2017 1.8 1.04 288 1.83 0.64 2103 1.91 0.72 2020 1.93 0.98 2062 1.98 0.69 2114 2 1.04 202 2.03 3.95 299 2.04 1.51 246 2.11 0.48 2072 2.16 0.84 2115 2.18 0.77 3770 2.18 0.77 2100 2.21 0.62 2157 2.3 0.8 2086 2.38 2.11 2129 2.67 0.92 2088 2.72 0.56 2038 2.73 0.42 2030 2.85 1.08 2111 2.9 0.87 2081 2.99 0.77 Max. deviations for best ID is within recommended range. Chosen best chemical ID is suitable for programming the gauge. Selection of best generic ID for ROM based devices like bq274xx Device / Family #1 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3142 bq27421-G1D: 4.4V LiCoO2 16.12 354 bq27411-G1C: 4.35V LiCoO2 18.99 128 bq27421-G1A: 4.2V LiCoO2 30.23 312 bq27421-G1B: 4.3V LiCoO2 38.98 Best generic ID 3142 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #2 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 354 bq27621: (ALT_CHEM2) 4.35V LiCoO2 18.99 1210 bq27621: (ALT_CHEM1) 4.3V LiCoO2 19.91 1202 bq27621: (default) 4.2V LiCoO2 20.01 Best generic ID 354 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule Device / Family #3 Generic Chem ID Device/ Voltage/ Chemistry max DOD error, % 3142 bq27426: (ALT-CHEM2) 4.4V LiCoO2 16.12 3230 bq27426: (default) 4.35V LiCoO2 18.67 1202 bq27426: (ALT_CHEM1) 4.2V LiCoO2 20.01 Best generic ID 3142 Warning: Generic ID Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule 0 0 0 Warning: voltage in V detected divider changed to 1 0 Warning: current in A detected divider changed to 1 0 Warning: First OCVpoint has non-zero current I= -0.000697 Please make sure you have a 2 hr relaxation period before the beginning of discharge. 0 Warning: Last OCVpoint has non-zero current I= -0.000497 Please make sure you have a 5 hr relaxation period after the end of discharge. Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 26.8671539362469 Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 26.8671539362469 Warning: Max R deviation ratio can not be checked because discharge hr-rate is above 12. Hr rate = 26.8671539362469