C2 Compliance Test Report



Test Summary - Overall

Total

 PASS

 FAIL

PASS Rate(%)

 INCOMPLETE

 NA

WARNING

NOT_SELECTED

ABORTED

NOT_EXECUTED

105

53

9

85%

1

22

0

0

0

20

Test Summary - All MOI

MOI Name

Total

 PASS

 FAIL

PASS Rate(%)

 INCOMPLETE

NA

 WARNING

 NOT_SELECTED

ABORTED

NOT_EXECUTED

PD2 Communication Engine Tests

21

9

5

64%

1

6

0

0

0

0

Power Delivery 3.0 Tests

84

44

4

91%

0

16

0

0

0

20

PD2 Communication Engine Tests- Result Summary

Sl No

Test ID

Test Name

Test Result

1

TDA.2.1.1.1

TDA.2.1.1.1 BMC PHY TX EYE

PASS

2

TDA.2.1.1.2

TDA.2.1.1.2 BMC PHY TX BIT

INCOMPLETE

3

TDA.2.1.2.2

TDA.2.1.2.2 BMC PHY RX INT REJ

PASS

4

TDA.2.1.2.1

TDA.2.1.2.1 BMC PHY RX BUSIDL

PASS

5

TDA.2.1.3.1

TDA.2.1.3.1 BMC PHY TERM

PASS

6

TDA.2.1.3.2

TDA.2.1.3.2 BMC PHY MSG

PASS

7

TDA.2.2.1

TDA.2.2.1 BMC PROT SEQ GETCAPS

FAIL

8

TDA.2.2.3

TDA.2.2.3 BMC PROT SEQ DRSWAP

FAIL

9

TDA.2.2.4

TDA.2.2.4 BMC PROT SEQ VCSWAP DFP

PASS

10

TDA.2.2.5

TDA.2.2.5 BMC PROT DISCOV

NA

11

TDA.2.2.6

TDA.2.2.6 BMC PROT SEQ PRSWAP

PASS

12

TDA.2.2.7

TDA.2.2.7 BMC PROT BIST NOT 5V SRC

PASS

13

TDA.2.2.8

TDA.2.2.8 BMC PROT REV NUM

NA

14

TDA.2.2.9

TDA.2.2.9 BMC PROT GSC REC

PASS

15

TDA.2.2.10

TDA.2.2.10 BMC PROT IGN PPS

NA

16

TDA.2.3.1.1

TDA.2.3.1.1 POW SRC LOAD P PC

FAIL

17

TDA.2.3.1.2

TDA.2.3.1.2 POW SRC LOAD CP ACC

FAIL

18

TDA.2.3.2.1

TDA.2.3.2.1 POW SRC TRANS P PC

FAIL

19

TDA.2.3.2.2

TDA.2.3.2.2 POW SRC TRANS CP ACC

NA

20

TDA.2.3.3.1

TDA.2.3.3.1 POW SNK TRANS C CP

NA

21

TDA.2.3.3.2

TDA.2.3.3.2 POW SNK TRANS PC

NA

PD2 Communication Engine Tests - Detailed Test Result

Test Status

Test Description

  PASS

   1. TDA.2.1.1.1 BMC PHY TX EYE (Click to View Protocol Trace)

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-1:

 

                    Valid Protocol response for BIST Request

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-2:

 

                    Valid BIST response pattern

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-3:

 

                    Eye diagram plot passed at Mid Crossing Level.

  PASS

 TDA.2.1.1.1 BMC PHY TX EYE-4:

 

                    BIST pattern duration 44.8589600 mS (Limit <= 60ms)

  PASS

 BMC_PHY_TX_EYE_5:

 

                    Rise time:
                    Average value = 479.624739 nS
                    Minimum value = 471.480013 nS
                    Maximum value = 487.698843 nS
                    Minimum Limit = 300 ns
                    
                    Fall time:
                    Average value = 589.097521 nS
                    Minimum value = 579.878408 nS
                    Maximum value = 597.367513 nS
                    Minimum Limit = 300 ns
                    

  INCOMPLETE

   2. TDA.2.1.1.2 BMC PHY TX BIT (Click to View Protocol Trace)

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-1:

 

                    Valid Protocol response for BIST Request

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-2:

 

                    Valid BIST response pattern

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-3:

 

                    Bit Rate is 302.939 Kbps. Test limit (270 ~ 330) Kbps
                    

  PASS

 TDA.2.1.1.2 BMC PHY TX BIT-4:

 

                    Bit Rate is 0.004 %. Test limit: X < 0.25%
                    

  INCOMPLETE

 TDA.2.1.1.2 BMC PHY TX BIT-5:

 

                    Invalid timestamp, please report this issue to GRL support with test data

  PASS

  3. TDA.2.1.2.2 BMC PHY RX INT REJ

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_4_TstrSink:

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_2_TstrSinkNoiseGrp1:

 

                    Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  PASS

 TDA.2.1.2.2 BMC PHY RX INT REJ_5_TstrSinkNoiseGrp3:

 

                    Total Sent BIST Test Data messages Count: 13362; Received GoodCRC: = 13362 )

  PASS

   4. TDA.2.1.2.1 BMC PHY RX BUSIDL (Click to View Protocol Trace)

  PASS

 TDA.2.1.2.1 BMC PHY RX BUSIDL1_TstrSink:

  PASS

 TDA.2.1.2.1 BMC PHY RX BUSIDL2_TstrSink:

  PASS

 TDA.2.1.2.1 BMC PHY RX BUSIDL3_TstrSink:

  PASS

   5. TDA.2.1.3.1 BMC PHY TERM (Click to View Protocol Trace)

  PASS

 TDA.2.1.3.1 BMC PHY TERM_1:

  PASS

 TDA.2.1.3.1 BMC PHY TERM_2:

 

                     CC-line voltage = 1.79V

  PASS

   6. TDA.2.1.3.2 BMC PHY MSG (Click to View Protocol Trace)

  NA

 TDA.2.1.3.2 BMC PHY MSG_SOPs_BIST_1:

  PASS

                               BMC_PHY_MSG_1:

  NA

                               BMC_PHY_MSG_2:

 

                                        Vendor Specifies DUT responds to SOP' when DFP mode, Hence skipped this test.

  NA

                               BMC_PHY_MSG_3:

 

                                        Vendor Specifies DUT responds to SOP'' when DFP mode, Hence skipped this test.

  PASS

                               BMC_PHY_MSG_4:

  PASS

                               BMC_PHY_MSG_5:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_PHY_ERR_2:

  PASS

                               BMC_PHY_MSG_6:

  PASS

                               BMC_PHY_MSG_7:

  PASS

                               BMC_PHY_MSG_8:

  PASS

                               BMC_PHY_MSG_9:

  PASS

                               BMC_PHY_MSG_10:

  PASS

                               BMC_PHY_MSG_11:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_init_3:

 

                    Message-ID initialization for Get_Sink_Cap is incremented.
                    Message-ID initialization for Get_Sink_Cap is incremented.

  PASS

                               BMC_PHY_MSG_12:

 

                                        Message-ID initialization for Get_Sink_Cap is incremented.

  PASS

                               BMC_PHY_MSG_13:

 

                                        Message-ID initialization for Get_Sink_Cap is incremented.

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_Cable_Reset_4:

  PASS

                               BMC_PHY_MSG_15:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_Rpt_5:

  PASS

                               BMC_PHY_MSG_18:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_HardRst_6:

  PASS

                               BMC_PHY_MSG_16:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_MsgID_SoftRst_7:

  PASS

                               BMC_PHY_MSG_14:

  PASS

 TDA.2.1.3.2 BMC PHY MSG_CRCCheck_8:

  PASS

                               BMC_PHY_MSG_19:

  PASS

                               PROT_PROC_GCRC_UUT_1:

  FAIL

   7. TDA.2.2.1 BMC PROT SEQ GETCAPS (Click to View Protocol Trace)

  PASS

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source):

  PASS

                               TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source)_(1):

 

                                        Protocol Index # #41

  PASS

                               TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSourceCap_UUT_Type-(Source)_(2):

  FAIL

 TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source):

 

                    DUT not responded for Get_sink cap for UUT type: provider_only. Get_Sink_cap protocol index # #0

  FAIL

                               TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source)_(3):

 

                                        DUT not responded for Get_sink cap for UUT type: provider_only. Get_Sink_cap protocol index # #51

  FAIL

                               TDA.2.2.1 BMC PROT SEQ GETCAPS_GetSinkCap_UUT-Type-(Source)_(4):

 

                                        DUT failed to respond reject message for Get_sink cap for UUT type: provider_only. Get_Sink_cap protocol index # #51

  FAIL

   8. TDA.2.2.3 BMC PROT SEQ DRSWAP (Click to View Protocol Trace)

  FAIL

 TDA.2.2.3 BMC PROT SEQ DRSWAP_DR-SwapDUTSrc_1_2:

 

                    DUT accepted data role swap message

  PASS

   9. TDA.2.2.4 BMC PROT SEQ VCSWAP DFP (Click to View Protocol Trace)

  PASS

 PT_TDA_2_2_4_BMC_PROT_SEQ_VCSWAP_DFP_DUT_Src_1_2:

  PASS

 PT_TDA_2_2_4_BMC_PROT_SEQ_VCSWAP_DFP_DUT_Src_3_4:

  PASS

 TDA_2_2_4_BMC_PROT_SEQ_VCSWAP_DFPDUT_Src_7:

  NA

   10. TDA.2.2.5 BMC PROT DISCOV (Click to View Protocol Trace)

 

                    This test is not applicable for the given DUT category

  PASS

   11. TDA.2.2.6 BMC PROT SEQ PRSWAP (Click to View Protocol Trace)

  PASS

 BMC_PROT_SEQ_SWAP_REJ_1:

  PASS

   12. TDA.2.2.7 BMC PROT BIST NOT 5V SRC (Click to View Protocol Trace)

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.628ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 58.002ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  NA

   13. TDA.2.2.8 BMC PROT REV NUM (Click to View Protocol Trace)

 

                     This test is not applicable for DUT's with Spec Rev 3 and above

  PASS

   14. TDA.2.2.9 BMC PROT GSC REC (Click to View Protocol Trace)

  PASS

 TDA.2.2.9 BMC PROT GSC REC_Get_SrcCap:

  NA

   15. TDA.2.2.10 BMC PROT IGN PPS (Click to View Protocol Trace)

 

                    Test case is not applicable for Revision 3.0 DUT's

  NA

 TDA.2.2.10 BMC PROT IGN PPS_1:

  NA

 TDA.2.2.10 BMC PROT IGN PPS_2:

  NA

 TDA.2.2.10 BMC PROT IGN PPS_3:

  FAIL

   16. TDA.2.3.1.1 POW SRC LOAD P PC (Click to View Protocol Trace)

  FAIL

 Power Rules Check:

 

                    PDOs matched with VIF
                    DUT advertised source power profile (PDP) : (27) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (45) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (98) was higher than the claimed source power(15 W )
                    Maximum offered power by DUT (98 W) is higher than the maximum power claimed by vendor in VIF(15 w)

  PASS

 Power Source Load test - PDO#1, 5.0V @ 3.00A:

  PASS

 Tester sends Request message for PDO#1 transition:

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.637ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 36.415ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 5.258V, and after Load: 5.257V , Limit:[4.750-5.500V] at Protocol index #51[ Measurement after timestamp41.7254466S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 5.257V, and after load 5.257V, Limit:[4.75-5.5V] at Protocol index #57 [Measurement after timestamp :42.4754368S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 5.289V, and after load 5.310V, Limit:[4.75-5.5V] at Protocol index #63 [Measurement after timestamp :43.2254407S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 5.319V, and after load 5.342V, Limit:[4.75-5.5V] at Protocol index #69 [Measurement after timestamp :43.9754963S]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 5.357V, and after load 5.376V, Limit:[4.75-5.5V] at Protocol index #75 [Measurement after timestamp :44.7254150S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 5.381V, and after load 5.357V, Limit:[4.75-5.5V] at Protocol index #81 [Measurement after timestamp :45.4754782S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 5.348V, and after load 5.318V, Limit:[4.75-5.5V] at Protocol index #87 [Measurement after timestamp :46.2254793S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 5.311V, and after load 5.289V, Limit:[4.75-5.5V] at Protocol index #93 [Measurement after timestamp :46.9754336S]:

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 5.278V, and after Load: 5.258V , Limit:[4.750-5.500V] at Protocol index #99[ Measurement after timestamp47.7254525S]:

  PASS

 Power Source Load test - PDO#2, 9.0V @ 3.00A:

  PASS

 Tester sends Request message for PDO#2 transition from 5.0V to 9.0V:

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.629ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.444ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 9.291V, and after Load: 9.292V , Limit:[8.550-9.450V] at Protocol index #114[ Measurement after timestamp76.9716878S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 9.294V, and after load 9.294V, Limit:[8.55-9.45V] at Protocol index #120 [Measurement after timestamp :77.7216471S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 9.328V, and after load 9.349V, Limit:[8.55-9.45V] at Protocol index #126 [Measurement after timestamp :78.4716850S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 9.358V, and after load 9.379V, Limit:[8.55-9.45V] at Protocol index #132 [Measurement after timestamp :79.2217690S]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 9.395V, and after load 9.413V, Limit:[8.55-9.45V] at Protocol index #138 [Measurement after timestamp :79.9716612S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 9.423V, and after load 9.394V, Limit:[8.55-9.45V] at Protocol index #144 [Measurement after timestamp :80.7218453S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 9.386V, and after load 9.357V, Limit:[8.55-9.45V] at Protocol index #150 [Measurement after timestamp :81.4716902S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 9.348V, and after load 9.327V, Limit:[8.55-9.45V] at Protocol index #156 [Measurement after timestamp :82.2217249S]:

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 9.316V, and after Load: 9.293V , Limit:[8.550-9.450V] at Protocol index #162[ Measurement after timestamp82.9717351S]:

  PASS

 Power Source Load test - PDO#3, 15.V @ 3.00A:

  PASS

 Tester sends Request message for PDO#3 transition from 9.0V to 15.V:

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.766ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.136ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 15.31V, and after Load: 15.31V , Limit:[14.25-15.75V] at Protocol index #177[ Measurement after timestamp112.249955S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 15.31V, and after load 15.31V, Limit:[14.25-15.75V] at Protocol index #183 [Measurement after timestamp :112.999788S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 15.34V, and after load 15.36V, Limit:[14.25-15.75V] at Protocol index #189 [Measurement after timestamp :113.749823S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 15.38V, and after load 15.40V, Limit:[14.25-15.75V] at Protocol index #195 [Measurement after timestamp :114.499768S]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 15.41V, and after load 15.43V, Limit:[14.25-15.75V] at Protocol index #201 [Measurement after timestamp :115.249707S]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 15.43V, and after load 15.41V, Limit:[14.25-15.75V] at Protocol index #207 [Measurement after timestamp :115.999740S]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 15.40V, and after load 15.37V, Limit:[14.25-15.75V] at Protocol index #213 [Measurement after timestamp :116.749620S]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 15.36V, and after load 15.34V, Limit:[14.25-15.75V] at Protocol index #219 [Measurement after timestamp :117.499604S]:

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 15.33V, and after Load: 15.31V , Limit:[14.25-15.75V] at Protocol index #225[ Measurement after timestamp118.249840S]:

  PASS

 Power Source Load test - PDO#4, 20.V @ 4.90A:

  PASS

 Tester sends Request message for PDO#4 transition from 15.V to 20.V:

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.632ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.566ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 19.66V, and after Load: 19.66V , Limit:[19.00-21.00V] at Protocol index #240[ Measurement after timestamp147.541661S]:

  PASS

 Load set to 1.23A: PASS Vbus voltage before load 19.66V, and after load 19.66V, Limit:[19-21V] at Protocol index #246 [Measurement after timestamp :148.291764S]:

  PASS

 Load set to 2.45A: PASS Vbus voltage before load 19.72V, and after load 19.75V, Limit:[19-21V] at Protocol index #252 [Measurement after timestamp :149.041888S]:

  PASS

 Load set to 3.68A: PASS Vbus voltage before load 19.77V, and after load 19.81V, Limit:[19-21V] at Protocol index #258 [Measurement after timestamp :149.791835S]:

  PASS

 Load set to 4.90A: PASS Vbus voltage before load 19.83V, and after load 19.86V, Limit:[19-21V] at Protocol index #264 [Measurement after timestamp :150.541787S]:

  PASS

 Load set to 3.68A: PASS Vbus voltage before load 19.87V, and after load 19.82V, Limit:[19-21V] at Protocol index #270 [Measurement after timestamp :151.291767S]:

  PASS

 Load set to 2.45A: PASS Vbus voltage before load 19.82V, and after load 19.77V, Limit:[19-21V] at Protocol index #276 [Measurement after timestamp :152.041669S]:

  PASS

 Load set to 1.23A: PASS Vbus voltage before load 19.76V, and after load 19.72V, Limit:[19-21V] at Protocol index #282 [Measurement after timestamp :152.791839S]:

  PASS

 Load set to 0.00A: PASS Vbus voltage before load 19.70V, and after Load: 19.66V , Limit:[19.00-21.00V] at Protocol index #288[ Measurement after timestamp153.541873S]:

  PASS

 Tester sends HardReset message and expects DUT to recover PD negotiation:

  PASS

                               PROT_PROC_HR_TSTR_1:

 

                                        Measured VBUS voltage: 19.6530451866405V. Limit[>19V.

  PASS

                               PROT_PROC_HR_TSTR_3:

 

                                        Vbus reached to Vsafe0V at :35.7782300 mS, Limit [<=650mS]

  PASS

                               PROT_PROC_HR_TSTR_4:

 

                                        Vbus Voltage after 660ms is :0.01847V. Measured at 168.06618614s. Expected limit[<2V].

  PASS

                               PROT_PROC_HR_TSTR_5:

 

                                        Vbus voltage at >1s after HardReset is:19.66051V

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

 Tester sends Request message with current higher than DUT's max supported current and expects Reject response from DUT:

  PASS

 PDO#4: Max supported current 4.90A, but tester sends 4.91A and expects Reject message:

  FAIL

   17. TDA.2.3.1.2 POW SRC LOAD CP ACC (Click to View Protocol Trace)

  PASS

 TDA_2_3_1_2_POW_SRC_LOAD_CP_ACC_1:

  FAIL

 TDA.2.3.1.2 POW SRC LOAD CP ACC_2:

 

                    PDOs matched with VIF
                    DUT advertised source power profile (PDP) : (27) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (45) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (98) was higher than the claimed source power(15 W )
                    Maximum offered power by DUT (98 W) is higher than the maximum power claimed by vendor in VIF(15 w)

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_1:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_1(3):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.641ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 36.403ms
                    PASS: Measured VBUS voltage at request message: 5.25V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.25V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 5.255V, and after load 5.255V, Limit:[4.75-5.5V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 5.288V, and after load 5.288V, Limit:[4.75-5.5V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 5.318V, and after load 5.318V, Limit:[4.75-5.5V]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 5.356V, and after load 5.356V, Limit:[4.75-5.5V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 5.370V, and after load 5.362V, Limit:[4.75-5.5V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 5.337V, and after load 5.327V, Limit:[4.75-5.5V]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 5.299V, and after load 5.292V, Limit:[4.75-5.5V]:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_2:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_2(3):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.63ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.53ms
                    PASS: Measured VBUS voltage at request message: 5.25V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.25V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.25V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 9.291V, and after load 9.291V, Limit:[8.55-9.45V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 9.324V, and after load 9.323V, Limit:[8.55-9.45V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 9.358V, and after load 9.357V, Limit:[8.55-9.45V]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 9.395V, and after load 9.395V, Limit:[8.55-9.45V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 9.412V, and after load 9.402V, Limit:[8.55-9.45V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 9.376V, and after load 9.366V, Limit:[8.55-9.45V]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 9.336V, and after load 9.328V, Limit:[8.55-9.45V]:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_3:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_3(3):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.63ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.348ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 15.3V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.3V. Expected range[14.25V ~ 15.75V]

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 15.31V, and after load 15.31V, Limit:[14.25-15.75V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 15.34V, and after load 15.34V, Limit:[14.25-15.75V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 15.38V, and after load 15.38V, Limit:[14.25-15.75V]:

  PASS

 Load set to 3.00A: PASS Vbus voltage before load 15.41V, and after load 15.41V, Limit:[14.25-15.75V]:

  PASS

 Load set to 2.25A: PASS Vbus voltage before load 15.42V, and after load 15.41V, Limit:[14.25-15.75V]:

  PASS

 Load set to 1.50A: PASS Vbus voltage before load 15.39V, and after load 15.38V, Limit:[14.25-15.75V]:

  PASS

 Load set to 750. mA: PASS Vbus voltage before load 15.35V, and after load 15.34V, Limit:[14.25-15.75V]:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_4:

  PASS

 TDA.2.3.1.2 POW SRC LOAD CP ACC_PDO_4(3):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.714ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.666ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

 Load set to 1.23A: PASS Vbus voltage before load 19.66V, and after load 19.66V, Limit:[19-21V]:

  PASS

 Load set to 2.45A: PASS Vbus voltage before load 19.72V, and after load 19.72V, Limit:[19-21V]:

  PASS

 Load set to 3.68A: PASS Vbus voltage before load 19.77V, and after load 19.77V, Limit:[19-21V]:

  PASS

 Load set to 4.90A: PASS Vbus voltage before load 19.83V, and after load 19.83V, Limit:[19-21V]:

  PASS

 Load set to 3.68A: PASS Vbus voltage before load 19.85V, and after load 19.84V, Limit:[19-21V]:

  PASS

 Load set to 2.45A: PASS Vbus voltage before load 19.80V, and after load 19.78V, Limit:[19-21V]:

  PASS

 Load set to 1.23A: PASS Vbus voltage before load 19.74V, and after load 19.72V, Limit:[19-21V]:

  PASS

 PT_TDA_2_3_1_2 POW SRC LOAD CP ACC_PROT_PROC_HR_TSTR:

  PASS

                               PROT_PROC_HR_TSTR_1:

 

                                        Measured VBUS voltage: 19.6530451866405V. Limit[>19V.

  PASS

                               PROT_PROC_HR_TSTR_3:

 

                                        Vbus reached to Vsafe0V at :36.0267000 mS, Limit [<=650mS]

  PASS

                               PROT_PROC_HR_TSTR_4:

 

                                        Vbus Voltage after 660ms is :0.01847V. Measured at 207.73357946s. Expected limit[<2V].

  PASS

                               PROT_PROC_HR_TSTR_5:

 

                                        Vbus voltage at >1s after HardReset is:19.66798V

  PASS

                               PROT_PROC_GCRC_UUT_1:

  FAIL

   18. TDA.2.3.2.1 POW SRC TRANS P PC (Click to View Protocol Trace)

  FAIL

 TDA.2.3.2.1 POW SRC TRANS P PC_1:

 

                    PDOs matched with VIF
                    DUT advertised source power profile (PDP) : (27) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (45) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (98) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (27) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (45) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (27) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (98) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (45) was higher than the claimed source power(15 W )
                    DUT advertised source power profile (PDP) : (98) was higher than the claimed source power(15 W )
                    Maximum offered power by DUT (98 W) is higher than the maximum power claimed by vendor in VIF(15 w)

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_2_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.624ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.359ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 9.3V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.3V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_1_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.651ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.782ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_3_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.664ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 55.762ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_1_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.63ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.59ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_4_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.633ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 58.021ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_2_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.631ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.968ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 9.3V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.3V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_3_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.63ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.247ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_2_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.631ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.881ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_4_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.627ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.635ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_3_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.629ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.885ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_4_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.625ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.6ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_1_cSnkBulk_Min(1µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.629ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 58.297ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_2_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.633ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.517ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_1_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.644ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.798ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.3V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.3V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_3_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.626ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 55.788ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_1_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.627ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.547ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_1_4_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.634ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 58.105ms
                    PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].
                    PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]
                    PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 5.26V. Expected range[4.75V ~ 5.5V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_2_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.642ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.873ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_3_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.626ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.283ms
                    PASS: Measured VBUS voltage at request message: 9.3V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.3V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_2_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.642ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 54.77ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_2_4_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.644ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 56.436ms
                    PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].
                    PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]
                    PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 9.29V. Expected range[8.55V ~ 9.45V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 9.29V. Expected range[8.55V ~ 9.45V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.67V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_3_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.633ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.975ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.67V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 15.31V. Expected range[14.25V ~ 15.75V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_3_4_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.622ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 53.587ms
                    PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].
                    PASS: Measured VBUS voltage at Accept message: 15.3V. Expected range[14.25V ~ 15.75V]
                    PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 15.31V. Expected range[14.25V ~ 15.75V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 15.3V. Expected range[14.25V ~ 15.75V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 19.66V. Expected range[19V ~ 21V]

  PASS

 TDA.2.3.2.1 POW SRC TRANS P PC_Trans_4_1_cSnkBulk_Max(10µF):

 

                    DUT responded with Accept message for Request message. Actual time interval is: 4.627ms
                    DUT responded with PS_RDY message for Accept message. Actual time interval is: 58.355ms
                    PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].
                    PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]
                    PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  PASS

                               PROT_PROC_GCRC_UUT_1:

  PASS

                               PROT_PROC_REQ_TSTR_4:

 

                                        PASS: Measured VBUS voltage at request message: 19.66V. Expected range[19V ~ 21V].

  PASS

                               PROT_PROC_REQ_TSTR_5:

 

                                        PASS: Measured VBUS voltage at Accept message: 19.66V. Expected range[19V ~ 21V]

  PASS

                               PROT_PROC_REQ_TSTR_6:

  PASS

                               PROT_PROC_REQ_TSTR_9:

 

                                        PASS: Measured VBUS voltage at PS_RDY 5.26V. Expected range[4.75V ~ 5.5V]

  NA

   19. TDA.2.3.2.2 POW SRC TRANS CP ACC (Click to View Protocol Trace)

 

                    Test is not applicable for Provider_Only DUT's

  NA

   20. TDA.2.3.3.1 POW SNK TRANS C CP (Click to View Protocol Trace)

 

                    Test is not applicable for Provider_Only DUT's

  NA

   21. TDA.2.3.3.2 POW SNK TRANS PC (Click to View Protocol Trace)

 

                    Test is not applicable for Provider_Only DUT's

Power Delivery 3.0 Tests- Result Summary

Sl No

Test ID

Test Name

Test Result

1

TD.PD.LL3.E1

TD.PD.LL3.E1 GoodCRC Specification Revision compatibility

PASS

2

TD.PD.LL3.E2

TD.PD.LL3.E2 Retransmission

PASS

3

TD.PD.LL3.E3

TD.PD.LL3.E3 GoodCRC Compatibility with PD2

PASS

4

TD.PD.SRC3.E1

TD.PD.SRC3.E1 Source Capability Fields Checks

PASS

5

TD.PD.SRC3.E2

TD.PD.SRC3.E2 Accept Fields Checks

PASS

6

TD.PD.SRC3.E3

TD.PD.SRC3.E3 PSRDY Fields Checks

PASS

7

TD.PD.SRC3.E4

TD.PD.SRC3.E4 Specification Revision Check after Contract

PASS

8

TD.PD.SRC3.E5

TD.PD.SRC3.E5 Source Capabilities Extended sent timely

PASS

9

TD.PD.SRC3.E6

TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks

PASS

10

TD.PD.SRC3.E7

TD.PD.SRC3.E7 Battery Status sent Timely

PASS

11

TD.PD.SRC3.E8

TD.PD.SRC3.E8 Battery Status Fields Checks

PASS

12

TD.PD.SRC3.E9

TD.PD.SRC3.E9 Battery Status Fields Checks Invalid Battery reference

PASS

13

TD.PD.SRC3.E10

TD.PD.SRC3.E10 Unrecognized Message Received in Ready State

PASS

14

TD.PD.SRC3.E11

TD.PD.SRC3.E11 Get Status Fields Checks

PASS

15

TD.PD.SRC3.E12

TD.PD.SRC3.E12 Get Battery Status Fields Checks

PASS

16

TD.PD.SRC3.E13

TD.PD.SRC3.E13 Status sent timely

PASS

17

TD.PD.SRC3.E14

TD.PD.SRC3.E14 Status Fields Checks

PASS

18

TD.PD.SRC3.E15

TD.PD.SRC3.E15 Battery Capabilities sent timely

PASS

19

TD.PD.SRC3.E16

TD.PD.SRC3.E16 Battery Capabilities Fields Checks

PASS

20

TD.PD.SRC3.E17

TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference

PASS

21

TD.PD.SRC3.E18

TD.PD.SRC3.E18 Manufacturer Info Sent Timely

PASS

22

TD.PD.SRC3.E19

TD.PD.SRC3.E19 Manufacturer Info Fields Checks

PASS

23

TD.PD.SRC3.E20

TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target

PASS

24

TD.PD.SRC3.E21

TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref

PASS

25

TD.PD.SRC3.E22

TD.PD.SRC3.E22 Cable Type Detection

PASS

26

TD.PD.SRC3.E23

TD.PD.SRC3.E23 Vconn Swap

PASS

27

TD.PD.SRC3.E24

TD.PD.SRC3.E24 Unexpected Message Received in Ready State

PASS

28

TD.PD.SRC3.E25

TD.PD.SRC3.E25 Receiving chunked extended message

PASS

29

TD.PD.SRC3.E26

TD.PD.SRC3.E26 Soft Reset sent regardless of Rp value

PASS

30

TD.PD.SRC3.E27

TD.PD.SRC3.E27 PPS Status Sent Timely

NA

31

TD.PD.SRC3.E28

TD.PD.SRC3.E28 PPS Status Fields Check

NA

32

TD.PD.SRC3.E29

TD.PD.SRC3.E29 SourcePPSCommTimer Deadline

NA

33

TD.PD.SRC3.E30

TD.PD.SRC3.E30 SourcePPSCommTimer Timeout

NA

34

TD.PD.SRC3.E31

TD.PD.SRC3.E31 SourcePPSCommTimer Stopped

NA

35

TD.PD.SRC3.E32

TD.PD.SRC3.E32 ChunkSenderResponseTimer Timeout

PASS

36

TD.PD.SRC3.E33

TD.PD.SRC3.E33 Country Codes Sent Timely

PASS

37

TD.PD.SRC3.E34

TD.PD.SRC3.E34 Country Codes Fields Checks

PASS

38

TD.PD.SRC3.E35

TD.PD.SRC3.E35 Country Info Sent Timely

PASS

39

TD.PD.SRC3.E36

TD.PD.SRC3.E36 Country Info Fields Checks

PASS

40

TD.PD.SNK3.E1

TD.PD.SNK3.E1 Request Fields Checks

NOT_EXECUTED

41

TD.PD.SNK3.E2

TD.PD.SNK3.E2 Unrecognized Message Received in Ready State

NOT_EXECUTED

42

TD.PD.SNK3.E3

TD.PD.SNK3.E3 Get Source Cap Extended Fields Checks

NOT_EXECUTED

43

TD.PD.SNK3.E4

TD.PD.SNK3.E4 SenderResponseTimer Deadline Source Capabilities Extended

NOT_EXECUTED

44

TD.PD.SNK3.E5

TD.PD.SNK3.E5 SenderResponseTimer Timeout Source Capabilities Extended

NOT_EXECUTED

45

TD.PD.SNK3.E6

TD.PD.SNK3.E6 Get Status Fields Checks

NOT_EXECUTED

46

TD.PD.SNK3.E7

TD.PD.SNK3.E7 Get Battery Status Fields Checks

NOT_EXECUTED

47

TD.PD.SNK3.E8

TD.PD.SNK3.E8 Status sent timely

NOT_EXECUTED

48

TD.PD.SNK3.E9

TD.PD.SNK3.E9 Manufacturer Info Sent Timely

NOT_EXECUTED

49

TD.PD.SNK3.E10

TD.PD.SNK3.E10 Source Capabilities Extended sent timely

NOT_EXECUTED

50

TD.PD.SNK3.E11

TD.PD.SNK3.E11 Receiving chunked extended message

NOT_EXECUTED

51

TD.PD.SNK3.E12

TD.PD.SNK3.E12 Soft Reset sent regardless of Rp value

NOT_EXECUTED

52

TD.PD.SNK3.E13

TD.PD.SNK3.E13 SinkPPSPeriodicTimer Timeout

NOT_EXECUTED

53

TD.PD.SNK3.E14

TD.PD.SNK3.E14 Request Fields Checks PPS

NOT_EXECUTED

54

TD.PD.SNK3.E15

TD.PD.SNK3.E15 Status Fields Checks

NOT_EXECUTED

55

TD.PD.SNK3.E16

TD.PD.SNK3.E16 Manufacturer Info Fields Checks

NOT_EXECUTED

56

TD.PD.SNK3.E17

TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target

NOT_EXECUTED

57

TD.PD.SNK3.E18

TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref

NOT_EXECUTED

58

TD.PD.SNK3.E19

TD.PD.SNK3.E19 ChunkSenderResponseTimer Timeout

NOT_EXECUTED

59

TD.PD.VDM3.E1

TD.PD.VDM3.E1 Fields Checks Discover Identity

FAIL

60

TD.PD.VDM3.E2

TD.PD.VDM3.E2 Unrecognized VID in Unstructured VDM

PASS

61

TD.PD.FRSISRC3.E1

TD.PD.FRSISRC3.E1 Normal Conditions

NA

62

TD.PD.FRSISRC3.E3

TD.PD.FRSISRC3.E3 Accept Not Sent

NA

63

TD.PD.FRSISRC3.E4

TD.PD.FRSISRC3.E4 PS_RDY Not Sent

NA

64

TD.PD.FRSISRC3.E5

TD.PD.FRSISRC3.E5 PSSourceOnTimer Deadline

NA

65

TD.PD.FRSISRC3.E6

TD.PD.FRSISRC3.E6 PSSourceOnTimer Timeout

NA

66

TD.PD.FRSISNK3.E1

TD.PD.FRSISNK3.E1 Normal Conditions

NA

67

TD.PD.FRSISNK3.E2

TD.PD.FRSISNK3.E2 FR_Swap Not Sent

NA

68

TD.PD.FRSISNK3.E3

TD.PD.FRSISNK3.E3 SenderResponseTimer Times Out

NA

69

TD.PD.FRSISNK3.E4

TD.PD.FRSISNK3.E4 PSSourceOffTimer Deadline

NA

70

TD.PD.FRSISNK3.E5

TD.PD.FRSISNK3.E5 PSSourceOffTimer Timeout

NA

71

TD.PD.FRSISNK3.E6

TD.PD.FRSISNK3.E6 PS_RDY Not Sent

NA

72

TD.PD.PRSISNK3.E1

TD.PD.PRSISNK3.E1 Collision Avoidance after PR-Swap

NOT_EXECUTED

73

TD.PD.VNDI3.E1

TD.PD.VNDI3.E1 Source Capabilities

FAIL

74

TD.PD.VNDI3.E2

TD.PD.VNDI3.E2 Request

PASS

75

TD.PD.VNDI3.E3

TD.PD.VNDI3.E3 VDM Identity

PASS

76

TD.PD.VNDI3.E4

TD.PD.VNDI3.E4 Manufacturer Info

PASS

77

TD.PD.VNDI3.E5

TD.PD.VNDI3.E5 Chunking Implemented

PASS

78

TD.PD.VNDI3.E6

TD.PD.VNDI3.E6 Unchunked Extended Messages Supported

PASS

79

TD.PD.VNDI3.E7

TD.PD.VNDI3.E7 Security Msgs Supported

PASS

80

TD.PD.VNDI3.E8

TD.PD.VNDI3.E8 Sink Capabilities

PASS

81

TD.PD.VNDI3.E9

TD.PD.VNDI3.E9 Source Capabilities Extended

PASS

82

TD.PD.VNDI3.E10

TD.PD.VNDI3.E10 PR Swap Source

FAIL

83

TD.PD.VNDI3.E11

TD.PD.VNDI3.E11 PR Swap Sink

FAIL

84

TD.PD.VNDI3.E12

TD.PD.VNDI3.E12 FR Swap Without Signaling Source

PASS

Power Delivery 3.0 Tests - Detailed Test Result

Test Status

Test Description

  PASS

   1. TD.PD.LL3.E1 GoodCRC Specification Revision compatibility (Click to View Protocol Trace)

  PASS

   2. TD.PD.LL3.E2 Retransmission (Click to View Protocol Trace)

  PASS

   3. TD.PD.LL3.E3 GoodCRC Compatibility with PD2 (Click to View Protocol Trace)

  PASS

   4. TD.PD.SRC3.E1 Source Capability Fields Checks (Click to View Protocol Trace)

  PASS

   5. TD.PD.SRC3.E2 Accept Fields Checks (Click to View Protocol Trace)

  PASS

 DUT sent accept message.:

  PASS

   6. TD.PD.SRC3.E3 PSRDY Fields Checks (Click to View Protocol Trace)

  PASS

 DUT sent PS_RDY message.:

  PASS

   7. TD.PD.SRC3.E4 Specification Revision Check after Contract (Click to View Protocol Trace)

  PASS

 DUT initiated source cap message:

  PASS

   8. TD.PD.SRC3.E5 Source Capabilities Extended sent timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  PASS

   9. TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E6 Source Capabilities Extended Fields Checks_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   10. TD.PD.SRC3.E7 Battery Status sent Timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message
                    DUT responded with Not Supported message

  PASS

   11. TD.PD.SRC3.E8 Battery Status Fields Checks (Click to View Protocol Trace)

 

                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.453ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.37ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.367ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.374ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.375ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.361ms
                    DUT responded with Not_Supported message for Get_Battery_Status message. Actual time interval is: 101.367ms

  PASS

   12. TD.PD.SRC3.E9 Battery Status Fields Checks Invalid Battery reference (Click to View Protocol Trace)

  PASS

   13. TD.PD.SRC3.E10 Unrecognized Message Received in Ready State (Click to View Protocol Trace)

 

                    DUT responded with Not_Supported message for Reserved message. Actual time interval is: 4.632ms

  PASS

 DUT responded with Not_Supported message :

  PASS

   14. TD.PD.SRC3.E11 Get Status Fields Checks (Click to View Protocol Trace)

 

                    DUT not responded for Alert message.

  PASS

   15. TD.PD.SRC3.E12 Get Battery Status Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E12 Get Battery Status Fields Checks_Unchunked(True):

 

                    DUT not responded for Alert message.

  PASS

 TD.PD.SRC3.E12 Get Battery Status Fields Checks_Unchunked(False):

 

                    DUT not responded for Alert message.

  PASS

   16. TD.PD.SRC3.E13 Status sent timely (Click to View Protocol Trace)

  PASS

 DUT responded with Not_Supported:

  PASS

   17. TD.PD.SRC3.E14 Status Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E14 Status Fields Checks_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E14 Status Fields Checks_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   18. TD.PD.SRC3.E15 Battery Capabilities sent timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  PASS

   19. TD.PD.SRC3.E16 Battery Capabilities Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E16 Battery Capabilities Fields Checks_Unchunked(True):

  PASS

 TD.PD.SRC3.E16 Battery Capabilities Fields Checks_Unchunked(False):

  PASS

   20. TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference_Unchunked(True):

 

                    DUT responded with Not Supported message
                    DUT sent (0) batteries in Source capabilities Extended message

  PASS

 TD.PD.SRC3.E17 Battery Capabilities Fields Checks Invalid Battery Reference_Unchunked(False):

 

                    DUT responded with Not Supported message
                    DUT sent (0) batteries in Source capabilities Extended message

  PASS

   21. TD.PD.SRC3.E18 Manufacturer Info Sent Timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  PASS

   22. TD.PD.SRC3.E19 Manufacturer Info Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E19 Manufacturer Info Fields Checks_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E19 Manufacturer Info Fields Checks_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   23. TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E20 Manufacturer Info Fields Checks Invalid Manufacturer Info Target_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   24. TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E21 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   25. TD.PD.SRC3.E22 Cable Type Detection (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E22 Cable Type Detection_1:

  PASS

 TD.PD.SRC3.E22 Cable Type Detection_2:

  PASS

   26. TD.PD.SRC3.E23 Vconn Swap (Click to View Protocol Trace)

 

                    DUT responded with Accept message for VCONN_Swap message. Actual time interval is: 17181.289ms

  PASS

   27. TD.PD.SRC3.E24 Unexpected Message Received in Ready State (Click to View Protocol Trace)

 

                    DUT responded with SoftReset message for Accept message. Actual time interval is: 0.998ms

  PASS

 DUT responded with SoftReset message.:

  PASS

   28. TD.PD.SRC3.E25 Receiving chunked extended message (Click to View Protocol Trace)

 

                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.627ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.631ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.631ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.63ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.638ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.631ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.648ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.635ms
                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.628ms

  PASS

   29. TD.PD.SRC3.E26 Soft Reset sent regardless of Rp value (Click to View Protocol Trace)

 

                    DUT responded with SoftReset message for SourceCap message. Actual time interval is: 1.306ms

  NA

   30. TD.PD.SRC3.E27 PPS Status Sent Timely (Click to View Protocol Trace)

 

                    Tester could not find APDO's{0}
                    

  NA

   31. TD.PD.SRC3.E28 PPS Status Fields Check (Click to View Protocol Trace)

 

                    Tester could not find APDO's{0}
                    

  NA

   32. TD.PD.SRC3.E29 SourcePPSCommTimer Deadline (Click to View Protocol Trace)

 

                    DUT does not contain APDO's{0}

  NA

   33. TD.PD.SRC3.E30 SourcePPSCommTimer Timeout (Click to View Protocol Trace)

 

                    DUT does not contains APDO's{0}

  NA

   34. TD.PD.SRC3.E31 SourcePPSCommTimer Stopped (Click to View Protocol Trace)

 

                    DUT does not contains APDO's{0}

  PASS

   35. TD.PD.SRC3.E32 ChunkSenderResponseTimer Timeout (Click to View Protocol Trace)

 

                    DUT responded with Reserved message for Reserved message. Actual time interval is: 9.627ms

  PASS

   36. TD.PD.SRC3.E33 Country Codes Sent Timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  PASS

   37. TD.PD.SRC3.E34 Country Codes Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E34 Country Codes Fields Checks_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E34 Country Codes Fields Checks_Unchunked(False):

 

                    DUT responded with Not Supported message

  PASS

   38. TD.PD.SRC3.E35 Country Info Sent Timely (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  PASS

   39. TD.PD.SRC3.E36 Country Info Fields Checks (Click to View Protocol Trace)

  PASS

 TD.PD.SRC3.E36 Country Info Fields Checks_Unchunked(True):

 

                    DUT responded with Not Supported message

  PASS

 TD.PD.SRC3.E36 Country Info Fields Checks_Unchunked(False):

 

                    DUT responded with Not Supported message

  NOT_EXECUTED

40. TD.PD.SNK3.E1 Request Fields Checks

  NOT_EXECUTED

41. TD.PD.SNK3.E2 Unrecognized Message Received in Ready State

  NOT_EXECUTED

42. TD.PD.SNK3.E3 Get Source Cap Extended Fields Checks

  NOT_EXECUTED

43. TD.PD.SNK3.E4 SenderResponseTimer Deadline Source Capabilities Extended

  NOT_EXECUTED

44. TD.PD.SNK3.E5 SenderResponseTimer Timeout Source Capabilities Extended

  NOT_EXECUTED

45. TD.PD.SNK3.E6 Get Status Fields Checks

  NOT_EXECUTED

46. TD.PD.SNK3.E7 Get Battery Status Fields Checks

  NOT_EXECUTED

47. TD.PD.SNK3.E8 Status sent timely

  NOT_EXECUTED

48. TD.PD.SNK3.E9 Manufacturer Info Sent Timely

  NOT_EXECUTED

49. TD.PD.SNK3.E10 Source Capabilities Extended sent timely

  NOT_EXECUTED

50. TD.PD.SNK3.E11 Receiving chunked extended message

  NOT_EXECUTED

51. TD.PD.SNK3.E12 Soft Reset sent regardless of Rp value

  NOT_EXECUTED

52. TD.PD.SNK3.E13 SinkPPSPeriodicTimer Timeout

  NOT_EXECUTED

53. TD.PD.SNK3.E14 Request Fields Checks PPS

  NOT_EXECUTED

54. TD.PD.SNK3.E15 Status Fields Checks

  NOT_EXECUTED

55. TD.PD.SNK3.E16 Manufacturer Info Fields Checks

  NOT_EXECUTED

56. TD.PD.SNK3.E17 Manufacturer Info Fields Checks Invalid Manufacturer Info Target

  NOT_EXECUTED

57. TD.PD.SNK3.E18 Manufacturer Info Fields Checks Invalid Manufacturer Info Ref

  NOT_EXECUTED

58. TD.PD.SNK3.E19 ChunkSenderResponseTimer Timeout

  FAIL

   59. TD.PD.VDM3.E1 Fields Checks Discover Identity (Click to View Protocol Trace)

 

                    (UFP VDO) : Dut sent Invalid message: VDO version field : 2
                    (DFP VDO) : Dut sent Invalid message: B27 : B28

  PASS

   60. TD.PD.VDM3.E2 Unrecognized VID in Unstructured VDM (Click to View Protocol Trace)

  NA

   61. TD.PD.FRSISRC3.E1 Normal Conditions (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   62. TD.PD.FRSISRC3.E3 Accept Not Sent (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   63. TD.PD.FRSISRC3.E4 PS_RDY Not Sent (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   64. TD.PD.FRSISRC3.E5 PSSourceOnTimer Deadline (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   65. TD.PD.FRSISRC3.E6 PSSourceOnTimer Timeout (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   66. TD.PD.FRSISNK3.E1 Normal Conditions (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   67. TD.PD.FRSISNK3.E2 FR_Swap Not Sent (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   68. TD.PD.FRSISNK3.E3 SenderResponseTimer Times Out (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   69. TD.PD.FRSISNK3.E4 PSSourceOffTimer Deadline (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   70. TD.PD.FRSISNK3.E5 PSSourceOffTimer Timeout (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NA

   71. TD.PD.FRSISNK3.E6 PS_RDY Not Sent (Click to View Protocol Trace)

 

                    This test case is not mandatory for Compliance mode but user run this test case in Informational mode

  NOT_EXECUTED

72. TD.PD.PRSISNK3.E1 Collision Avoidance after PR-Swap

  FAIL

   73. TD.PD.VNDI3.E1 Source Capabilities (Click to View Protocol Trace)

 

                    DUT PDO's not match with VI file {DUT sent: 4PDO's ~ Vi-File:1PDO's} --count(4)
                    

  FAIL

 DUT sent SourceCap message:

  FAIL

 DUT sent SourceCap message:

  FAIL

 DUT sent SourceCap message:

  FAIL

 DUT sent SourceCap message:

  PASS

   74. TD.PD.VNDI3.E2 Request (Click to View Protocol Trace)

  PASS

   75. TD.PD.VNDI3.E3 VDM Identity (Click to View Protocol Trace)

  PASS

   76. TD.PD.VNDI3.E4 Manufacturer Info (Click to View Protocol Trace)

  PASS

   77. TD.PD.VNDI3.E5 Chunking Implemented (Click to View Protocol Trace)

 

                    DUT responded with Reserved message for Reserved message. Actual time interval is: 4.629ms

  PASS

   78. TD.PD.VNDI3.E6 Unchunked Extended Messages Supported (Click to View Protocol Trace)

 

                    DUT responded with Not_Supported message for Reserved message. Actual time interval is: 4.628ms

  PASS

   79. TD.PD.VNDI3.E7 Security Msgs Supported (Click to View Protocol Trace)

  PASS

   80. TD.PD.VNDI3.E8 Sink Capabilities (Click to View Protocol Trace)

  PASS

   81. TD.PD.VNDI3.E9 Source Capabilities Extended (Click to View Protocol Trace)

 

                    DUT responded with Not Supported message

  FAIL

   82. TD.PD.VNDI3.E10 PR Swap Source (Click to View Protocol Trace)

 

                    Provider DUT sent Reject message for PR_Swap since 3.0 DUT doesn't support Reject message

  FAIL

   83. TD.PD.VNDI3.E11 PR Swap Sink (Click to View Protocol Trace)

 

                    In VIF File PD_PORT_TYPE Field not Contains Consumer_provider or DRP.

  PASS

   84. TD.PD.VNDI3.E12 FR Swap Without Signaling Source (Click to View Protocol Trace)

BMC Eye Diagram


Eye Diagram

DUT Information

Manufacturer

TI

Model Number

TPS659xx

Serial Number

1

Test Information

Test Lab

EV Cert

Test_Engineer

Marina

Remarks

PA

Date_and_Time

3/16/2023 6:04:25 PM

Controller and Instrument Information

Parameter

Value

GRL_USB_PD_Controller_Serial_No

298.298.298.220.255.

GRL_USB_PD_Software_Version

1.6.11.0

GRL_USB_PD_Firmware_Version

2.1.8

GRL USB-PD Ethernet Buffer Size

62K

GRL USB-PD Eload Firmware Version

9.8 / 9.8

Board Calibration

Calibration Expired

RX mask Power selection

Neutral Power

Device_Type

Provider Only

Cable Type

GRL_SPL_CABLE_1

Impedance (milli ohm)

45

COMMUNICATION_ENGINE_TESTS CTS Version

v1.09

COMPLIANCE_TEST_PD3 CTS Version

v1.19

VIF_File_Name

WS-UTD43-B-PD-907-14-14-AE-E6-VIF-OK.xml

Noise Pattern Generation:

Two-Tone Noise

Application mode

Compliance

Execution Time(In Minutes)

65

Power Delivery 3.0 Tests Information

Parameter

Value

FR_Swap AUTO Box Connected

False

Product Capabilities

Parameter

VendorInfoFile

GetCapabilities

VIF_Specification

3.20

Vendor_Name

TI

Model_Part_Number

TPS659xx

Product_Revision

1

TID

0

VIF_Product_Type

Port Product

Certification_Type

Silicon

VCONN_Swap_To_On_Supported

YES

VCONN_Swap_To_Off_Supported

YES

Responds_To_Discov_SOP_UFP

YES

Responds_To_Discov_SOP_DFP

YES

Attempts_Discov_SOP

YES

YES

Power_Interruption_Available

No Interruption Possible

ID_Header_Connector_Type_SOP

USB Type-C Receptacle

Chunking_Implemented_SOP

YES

Unchunked_Extended_Messages_Supported

YES

YES

Security_Msgs_Supported_SOP

NO

NO

Num_Fixed_Batteries

0

Num_Swappable_Battery_Slots

0

Type_C_Can_Act_As_Host

YES

Type_C_Can_Act_As_Device

YES

Type_C_Implements_Try_SRC

NO

Type_C_Implements_Try_SNK

NO

Type_C_Supports_Audio_Accessory

NO

Type_C_Is_VCONN_Powered_Accessory

NO

Type_C_Supports_VCONN_Powered_Accessory

YES

Type_C_Is_Debug_Target_SRC

NO

Type_C_Is_Debug_Target_SNK

NO

Captive_Cable

NO

NO

RP_Value

3A

Type_C_Port_On_Hub

NO

Type_C_Power_Source

Both

Type_C_Sources_VCONN

YES

Type_C_Is_Alt_Mode_Controller

YES

Type_C_Is_Alt_Mode_Adapter

NO

USB4_Max_Speed

Gen 3 (40Gb)

USB4_DFP_Supported

YES

USB4_UFP_Supported

YES

USB4_USB3_Tunneling_Supported

YES

USB4_DP_Tunneling_Supported

YES

USB4_PCIe_Tunneling_Supported

YES

USB4_TBT3_Compatibility_Supported

YES

USB4_CL1_State_Supported

YES

USB4_CL2_State_Supported

YES

USB4_Num_Retimers

0

USB4_DP_Bit_Rate

HBR3

USB4_Num_DP_Lanes

4 lanes

USB4_Lane_0_Adapter

4

Host_Supports_USB_Data

YES

Host_Speed

USB 3.2 Gen 2x2

Host_Contains_Captive_Retimer

NO

Host_Truncates_DP_For_tDHPResponse

NO

Host_Is_Embedded

NO

Host_Suspend_Supported

YES

Is_DFP_On_Hub

NO

Device_Supports_USB_Data

0

Device_Speed

USB 3.2 Gen 2x2

Device_Contains_Captive_Retimer

NO

Device_Truncates_DP_For_tDHPResponse

NO

FR_Swap_Type_C_Current_Capability_As_Initial_Sink

Fast Swap not Supported

Master_Port

YES

Accepts_PR_Swap_As_Src

NO

Accepts_PR_Swap_As_Snk

YES

Requests_PR_Swap_As_Src

NO

Requests_PR_Swap_As_Snk

YES

FR_Swap_Supported_As_Initial_Sink

NO

XID_SOP

None

Data_Capable_As_USB_Host_SOP

YES

Data_Capable_As_USB_Device_SOP

YES

Product_Type_UFP_SOP

PDUSB Peripheral

Product_Type_DFP_SOP

PDUSB HUB

DFP_VDO_Port_Number

1

Modal_Operation_Supported_SOP

YES

USB_VID_SOP

0x2629

PID_SOP

0xd43

bcdDevice_SOP

0x714

Product_Total_Source_Power_mW

143000

Port_Source_Power_Type

Assured

Port_Label

                 1

1

Connector_Type

Type-C

USB TYPE_C

USB4_Supported

YES

USB4_Router_Index

3

USB_PD_Support

YES

YES

PD_Port_Type

Provider Only

Provider Only

Type_C_State_Machine

SRC

SRC

Port_Battery_Powered

NO

BC_1_2_Support

None

BC_1_2_Charging_Port_Type

Both

EPR_Mode_Capable

NO

EPR_Supported_As_Src

NO

EPR_Supported_As_Snk

NO

Data_Reset_Supported

NO

Enter_USB_Supported

NO

PD_Specification_Revision

Revision 3.0

Revision 3.0

PD_Spec_Revision_Major

3

3

PD_Spec_Revision_Minor

0

0

PD_Spec_Version_Major

2

0

PD_Spec_Version_Minor

0

0

SOP_Capable

YES

YES

SOP_P_Capable

YES

YES

SOP_PP_Capable

YES

NO

SOP_P_Debug_Capable

NO

NO

SOP_PP_Debug_Capable

NO

NO

Manufacturer_Info_Supported_Port

NO

NO

Manufacturer_Info_VID_Port

0x2629

0000

Manufacturer_Info_PID_Port

0xd43

0000

USB_Comms_Capable

YES

YES

DR_Swap_To_DFP_Supported

YES

NO

DR_Swap_To_UFP_Supported

NO

YES

Unconstrained_Power

YES

YES

PD_Power_As_Source

15000

Port Product

USB_Suspend_May_Be_Cleared

YES

98000

Sends_Pings

NO

YES

Num_Src_PDOs

1

NO

PD_OC_Protection

YES

4

PD_OCP_Method

Both

NO

PD_Power_As_Sink

0

No_USB_Suspend_May_Be_Set

YES

0

GiveBack_May_Be_Set

NO

Higher_Capability_Set

NO

FR_Swap_Reqd_Type_C_Current_As_Initial_Source

FR_Swap not supported

NO

Num_Snk_PDOs

1

FR_Swap not supported

SVID_Fixed_SOP

YES

1

Num_SVIDs_Min_SOP

2

Num_SVIDs_Max_SOP

2

Source Capabilities

Parameter

VendorInfoFile

GetCapabilities

Src_PDO_Supply_Type #1

Fixed

Fixed

Src_PDO_Peak_Current #1

100% IOC

100% IOC

Src_PDO_Voltage #1

5 V

5000 mV

Src_PDO_Max_Current #1

3 A

3000 mA

Src_PD_OCP_OC_Debounce #1

1 msec

Src_PD_OCP_OC_Threshold #1

3000 mA

Src_PD_OCP_UV_Debounce #1

1 msec

Src_PD_OCP_UV_Threshold_Type #1

Percentage

Src_PD_OCP_UV_Threshold #1

20 %

Sink Capabilities

Parameter

VendorInfoFile

GetCapabilities

Snk_PDO_Supply_Type #1

Fixed

Fixed

Snk_PDO_Voltage #1

5 V

5000 mV

Snk_PDO_Op_Current #1

0 A

0 mA

SVIdsList

Parameter

VendorInfoFile

GetCapabilities

SVID_SOP

8087

SVID_Modes_Fixed_SOP

YES

SVID_Num_Modes_Min_SOP

1

SVID_Num_Modes_Max_SOP

1

SVID_Mode_Enter_SOP

YES

SVID_Mode_Recog_Value_SOP

0x00000001

SVID_SOP

FF01

SVID_Modes_Fixed_SOP

YES

SVID_Num_Modes_Min_SOP

1

SVID_Num_Modes_Max_SOP

1

SVID_Mode_Enter_SOP

YES

SVID_Mode_Recog_Value_SOP

0x000C0045

DUT Max Power

Power

98