WARNING - Model Model1: POWER Clamp : Typical value never becomes zero WARNING - Model Model1: POWER Clamp : Minimum value never becomes zero WARNING - Model Model1: POWER Clamp : Maximum value never becomes zero NOTE (line 1014) - Pulldown Maximum data is non-monotonic NOTE (line 1016) - Pulldown Typical data is non-monotonic NOTE (line 1019) - Pulldown Minimum data is non-monotonic NOTE (line 1104) - Pullup Maximum data is non-monotonic NOTE (line 1105) - Pullup Typical data is non-monotonic NOTE (line 1108) - Pullup Minimum data is non-monotonic NOTE (line 1825) - Pulldown Maximum data is non-monotonic NOTE (line 1827) - Pulldown Typical data is non-monotonic NOTE (line 1830) - Pulldown Minimum data is non-monotonic NOTE (line 1915) - Pullup Maximum data is non-monotonic NOTE (line 1916) - Pullup Typical data is non-monotonic NOTE (line 1919) - Pullup Minimum data is non-monotonic NOTE (line 2636) - Pulldown Maximum data is non-monotonic NOTE (line 2638) - Pulldown Typical data is non-monotonic NOTE (line 2641) - Pulldown Minimum data is non-monotonic NOTE (line 2726) - Pullup Maximum data is non-monotonic NOTE (line 2727) - Pullup Typical data is non-monotonic NOTE (line 2730) - Pullup Minimum data is non-monotonic WARNING - Model Model3: GND Clamp : Typical value never becomes zero WARNING - Model Model3: GND Clamp : Maximum value never becomes zero NOTE (line 3452) - Pulldown Typical data is non-monotonic NOTE (line 3452) - Pulldown Maximum data is non-monotonic NOTE (line 3453) - Pulldown Minimum data is non-monotonic NOTE (line 3541) - Pullup Maximum data is non-monotonic NOTE (line 3543) - Pullup Typical data is non-monotonic NOTE (line 3546) - Pullup Minimum data is non-monotonic NOTE (line 4294) - Pulldown Typical data is non-monotonic NOTE (line 4294) - Pulldown Maximum data is non-monotonic NOTE (line 4295) - Pulldown Minimum data is non-monotonic NOTE (line 4383) - Pullup Maximum data is non-monotonic NOTE (line 4385) - Pullup Typical data is non-monotonic NOTE (line 4388) - Pullup Minimum data is non-monotonic NOTE (line 5797) - Pulldown Typical data is non-monotonic NOTE (line 5797) - Pulldown Maximum data is non-monotonic NOTE (line 5798) - Pulldown Minimum data is non-monotonic NOTE (line 5886) - Pullup Maximum data is non-monotonic NOTE (line 5888) - Pullup Typical data is non-monotonic NOTE (line 5891) - Pullup Minimum data is non-monotonic NOTE (line 6639) - Pulldown Typical data is non-monotonic NOTE (line 6639) - Pulldown Maximum data is non-monotonic NOTE (line 6640) - Pulldown Minimum data is non-monotonic NOTE (line 6728) - Pullup Maximum data is non-monotonic NOTE (line 6730) - Pullup Typical data is non-monotonic NOTE (line 6733) - Pullup Minimum data is non-monotonic NOTE (line 7770) - Pulldown Maximum data is non-monotonic NOTE (line 7772) - Pulldown Typical data is non-monotonic NOTE (line 7775) - Pulldown Minimum data is non-monotonic NOTE (line 8282) - Pulldown Maximum data is non-monotonic NOTE (line 8284) - Pulldown Typical data is non-monotonic NOTE (line 8287) - Pulldown Minimum data is non-monotonic WARNING - Model Model15: POWER Clamp : Typical value never becomes zero WARNING - Model Model15: POWER Clamp : Minimum value never becomes zero WARNING - Model Model15: POWER Clamp : Maximum value never becomes zero NOTE (line 9004) - Pulldown Maximum data is non-monotonic NOTE (line 9006) - Pulldown Typical data is non-monotonic NOTE (line 9009) - Pulldown Minimum data is non-monotonic NOTE (line 9094) - Pullup Maximum data is non-monotonic NOTE (line 9095) - Pullup Typical data is non-monotonic NOTE (line 9098) - Pullup Minimum data is non-monotonic NOTE (line 9815) - Pulldown Maximum data is non-monotonic NOTE (line 9817) - Pulldown Typical data is non-monotonic NOTE (line 9820) - Pulldown Minimum data is non-monotonic NOTE (line 9905) - Pullup Maximum data is non-monotonic NOTE (line 9906) - Pullup Typical data is non-monotonic NOTE (line 9909) - Pullup Minimum data is non-monotonic NOTE (line 10626) - Pulldown Maximum data is non-monotonic NOTE (line 10628) - Pulldown Typical data is non-monotonic NOTE (line 10631) - Pulldown Minimum data is non-monotonic NOTE (line 10716) - Pullup Maximum data is non-monotonic NOTE (line 10717) - Pullup Typical data is non-monotonic NOTE (line 10720) - Pullup Minimum data is non-monotonic WARNING - Model Model17: GND Clamp : Typical value never becomes zero WARNING - Model Model17: GND Clamp : Maximum value never becomes zero WARNING - Model Model18: POWER Clamp : Typical value never becomes zero WARNING - Model Model18: POWER Clamp : Minimum value never becomes zero WARNING - Model Model18: POWER Clamp : Maximum value never becomes zero NOTE (line 11433) - Pulldown Maximum data is non-monotonic NOTE (line 11437) - Pulldown Typical data is non-monotonic NOTE (line 11440) - Pulldown Minimum data is non-monotonic NOTE (line 11521) - Pullup Maximum data is non-monotonic NOTE (line 11528) - Pullup Typical data is non-monotonic NOTE (line 11588) - Pullup Minimum data is non-monotonic NOTE (line 12116) - Pulldown Maximum data is non-monotonic NOTE (line 12120) - Pulldown Typical data is non-monotonic NOTE (line 12123) - Pulldown Minimum data is non-monotonic NOTE (line 12204) - Pullup Maximum data is non-monotonic NOTE (line 12211) - Pullup Typical data is non-monotonic NOTE (line 12271) - Pullup Minimum data is non-monotonic NOTE (line 12799) - Pulldown Maximum data is non-monotonic NOTE (line 12803) - Pulldown Typical data is non-monotonic NOTE (line 12806) - Pulldown Minimum data is non-monotonic NOTE (line 12887) - Pullup Maximum data is non-monotonic NOTE (line 12894) - Pullup Typical data is non-monotonic NOTE (line 12954) - Pullup Minimum data is non-monotonic WARNING - Model Model20: GND Clamp : Maximum value never becomes zero NOTE (line 13486) - Pulldown Typical data is non-monotonic NOTE (line 13486) - Pulldown Maximum data is non-monotonic NOTE (line 13487) - Pulldown Minimum data is non-monotonic NOTE (line 13575) - Pullup Maximum data is non-monotonic NOTE (line 13577) - Pullup Typical data is non-monotonic NOTE (line 13580) - Pullup Minimum data is non-monotonic NOTE (line 14323) - Pulldown Typical data is non-monotonic NOTE (line 14323) - Pulldown Maximum data is non-monotonic NOTE (line 14324) - Pulldown Minimum data is non-monotonic NOTE (line 14412) - Pullup Maximum data is non-monotonic NOTE (line 14414) - Pullup Typical data is non-monotonic NOTE (line 14417) - Pullup Minimum data is non-monotonic NOTE (line 15048) - Pulldown Maximum data is non-monotonic NOTE (line 15050) - Pulldown Typical data is non-monotonic NOTE (line 15054) - Pulldown Minimum data is non-monotonic NOTE (line 15214) - Pullup Minimum data is non-monotonic NOTE (line 15216) - Pullup Typical data is non-monotonic NOTE (line 15217) - Pullup Maximum data is non-monotonic WARNING - Model Model24: POWER Clamp : Typical value never becomes zero WARNING - Model Model24: POWER Clamp : Minimum value never becomes zero WARNING - Model Model24: POWER Clamp : Maximum value never becomes zero NOTE (line 19568) - Pulldown Maximum data is non-monotonic NOTE (line 19570) - Pulldown Typical data is non-monotonic NOTE (line 19573) - Pulldown Minimum data is non-monotonic NOTE (line 19658) - Pullup Maximum data is non-monotonic NOTE (line 19659) - Pullup Typical data is non-monotonic NOTE (line 19662) - Pullup Minimum data is non-monotonic NOTE (line 20379) - Pulldown Maximum data is non-monotonic NOTE (line 20381) - Pulldown Typical data is non-monotonic NOTE (line 20384) - Pulldown Minimum data is non-monotonic NOTE (line 20469) - Pullup Maximum data is non-monotonic NOTE (line 20470) - Pullup Typical data is non-monotonic NOTE (line 20473) - Pullup Minimum data is non-monotonic NOTE (line 21190) - Pulldown Maximum data is non-monotonic NOTE (line 21192) - Pulldown Typical data is non-monotonic NOTE (line 21195) - Pulldown Minimum data is non-monotonic NOTE (line 21280) - Pullup Maximum data is non-monotonic NOTE (line 21281) - Pullup Typical data is non-monotonic NOTE (line 21284) - Pullup Minimum data is non-monotonic WARNING - Model Model26: GND Clamp : Typical value never becomes zero WARNING - Model Model26: GND Clamp : Maximum value never becomes zero NOTE (line 21896) - Pulldown Maximum data is non-monotonic NOTE (line 21898) - Pulldown Typical data is non-monotonic NOTE (line 21901) - Pulldown Minimum data is non-monotonic NOTE (line 21986) - Pullup Maximum data is non-monotonic NOTE (line 21987) - Pullup Typical data is non-monotonic NOTE (line 21988) - Pullup Minimum data is non-monotonic NOTE (line 22151) - GND Clamp Typical data is non-monotonic NOTE (line 22151) - GND Clamp Minimum data is non-monotonic NOTE (line 22151) - GND Clamp Maximum data is non-monotonic NOTE (line 22714) - Pulldown Maximum data is non-monotonic NOTE (line 22716) - Pulldown Typical data is non-monotonic NOTE (line 22719) - Pulldown Minimum data is non-monotonic NOTE (line 22804) - Pullup Maximum data is non-monotonic NOTE (line 22805) - Pullup Typical data is non-monotonic NOTE (line 22806) - Pullup Minimum data is non-monotonic NOTE (line 24033) - Pulldown Typical data is non-monotonic NOTE (line 24033) - Pulldown Maximum data is non-monotonic NOTE (line 24034) - Pulldown Minimum data is non-monotonic NOTE (line 24122) - Pullup Maximum data is non-monotonic NOTE (line 24124) - Pullup Typical data is non-monotonic NOTE (line 24127) - Pullup Minimum data is non-monotonic NOTE (line 24870) - Pulldown Typical data is non-monotonic NOTE (line 24870) - Pulldown Maximum data is non-monotonic NOTE (line 24871) - Pulldown Minimum data is non-monotonic NOTE (line 24959) - Pullup Maximum data is non-monotonic NOTE (line 24961) - Pullup Typical data is non-monotonic NOTE (line 24964) - Pullup Minimum data is non-monotonic WARNING - Model Model35: POWER Clamp : Typical value never becomes zero WARNING - Model Model35: POWER Clamp : Minimum value never becomes zero WARNING - Model Model35: POWER Clamp : Maximum value never becomes zero NOTE (line 26106) - Pulldown Maximum data is non-monotonic NOTE (line 26108) - Pulldown Typical data is non-monotonic NOTE (line 26111) - Pulldown Minimum data is non-monotonic NOTE (line 26190) - Pullup Maximum data is non-monotonic NOTE (line 26191) - Pullup Typical data is non-monotonic NOTE (line 26192) - Pullup Minimum data is non-monotonic WARNING - Model Model36: POWER Clamp : Typical value never becomes zero WARNING - Model Model36: POWER Clamp : Minimum value never becomes zero WARNING - Model Model36: POWER Clamp : Maximum value never becomes zero NOTE (line 26862) - Pulldown Maximum data is non-monotonic NOTE (line 26864) - Pulldown Typical data is non-monotonic NOTE (line 26867) - Pulldown Minimum data is non-monotonic NOTE (line 26946) - Pullup Maximum data is non-monotonic NOTE (line 26947) - Pullup Typical data is non-monotonic NOTE (line 26948) - Pullup Minimum data is non-monotonic WARNING - Model Model37: POWER Clamp : Typical value never becomes zero WARNING - Model Model37: POWER Clamp : Minimum value never becomes zero WARNING - Model Model37: POWER Clamp : Maximum value never becomes zero NOTE (line 27659) - Pulldown Maximum data is non-monotonic NOTE (line 27661) - Pulldown Typical data is non-monotonic NOTE (line 27664) - Pulldown Minimum data is non-monotonic NOTE (line 27743) - Pullup Maximum data is non-monotonic NOTE (line 27744) - Pullup Typical data is non-monotonic NOTE (line 27745) - Pullup Minimum data is non-monotonic WARNING - Model Model38: POWER Clamp : Typical value never becomes zero WARNING - Model Model38: POWER Clamp : Minimum value never becomes zero WARNING - Model Model38: POWER Clamp : Maximum value never becomes zero NOTE (line 28452) - Pulldown Maximum data is non-monotonic NOTE (line 28454) - Pulldown Typical data is non-monotonic NOTE (line 28457) - Pulldown Minimum data is non-monotonic NOTE (line 28536) - Pullup Maximum data is non-monotonic NOTE (line 28537) - Pullup Typical data is non-monotonic NOTE (line 28538) - Pullup Minimum data is non-monotonic NOTE (line 29232) - Pulldown Maximum data is non-monotonic NOTE (line 29234) - Pulldown Typical data is non-monotonic NOTE (line 29237) - Pulldown Minimum data is non-monotonic NOTE (line 29316) - Pullup Maximum data is non-monotonic NOTE (line 29317) - Pullup Typical data is non-monotonic NOTE (line 29318) - Pullup Minimum data is non-monotonic NOTE (line 30029) - Pulldown Maximum data is non-monotonic NOTE (line 30031) - Pulldown Typical data is non-monotonic NOTE (line 30034) - Pulldown Minimum data is non-monotonic NOTE (line 30113) - Pullup Maximum data is non-monotonic NOTE (line 30114) - Pullup Typical data is non-monotonic NOTE (line 30115) - Pullup Minimum data is non-monotonic NOTE (line 30823) - Pulldown Maximum data is non-monotonic NOTE (line 30825) - Pulldown Typical data is non-monotonic NOTE (line 30828) - Pulldown Minimum data is non-monotonic NOTE (line 30907) - Pullup Maximum data is non-monotonic NOTE (line 30908) - Pullup Typical data is non-monotonic NOTE (line 30909) - Pullup Minimum data is non-monotonic NOTE (line 31603) - Pulldown Maximum data is non-monotonic NOTE (line 31605) - Pulldown Typical data is non-monotonic NOTE (line 31608) - Pulldown Minimum data is non-monotonic NOTE (line 31687) - Pullup Maximum data is non-monotonic NOTE (line 31688) - Pullup Typical data is non-monotonic NOTE (line 31689) - Pullup Minimum data is non-monotonic NOTE (line 32359) - Pulldown Maximum data is non-monotonic NOTE (line 32361) - Pulldown Typical data is non-monotonic NOTE (line 32364) - Pulldown Minimum data is non-monotonic NOTE (line 32443) - Pullup Maximum data is non-monotonic NOTE (line 32444) - Pullup Typical data is non-monotonic NOTE (line 32445) - Pullup Minimum data is non-monotonic WARNING - Model Model43: GND Clamp : Typical value never becomes zero WARNING - Model Model43: GND Clamp : Maximum value never becomes zero NOTE (line 33115) - Pulldown Maximum data is non-monotonic NOTE (line 33117) - Pulldown Typical data is non-monotonic NOTE (line 33120) - Pulldown Minimum data is non-monotonic NOTE (line 33199) - Pullup Maximum data is non-monotonic NOTE (line 33200) - Pullup Typical data is non-monotonic NOTE (line 33201) - Pullup Minimum data is non-monotonic WARNING - Model Model44: GND Clamp : Typical value never becomes zero WARNING - Model Model44: GND Clamp : Maximum value never becomes zero NOTE (line 33912) - Pulldown Maximum data is non-monotonic NOTE (line 33914) - Pulldown Typical data is non-monotonic NOTE (line 33917) - Pulldown Minimum data is non-monotonic NOTE (line 33996) - Pullup Maximum data is non-monotonic NOTE (line 33997) - Pullup Typical data is non-monotonic NOTE (line 33998) - Pullup Minimum data is non-monotonic WARNING - Model Model45: GND Clamp : Typical value never becomes zero WARNING - Model Model45: GND Clamp : Maximum value never becomes zero NOTE (line 34706) - Pulldown Maximum data is non-monotonic NOTE (line 34708) - Pulldown Typical data is non-monotonic NOTE (line 34711) - Pulldown Minimum data is non-monotonic NOTE (line 34790) - Pullup Maximum data is non-monotonic NOTE (line 34791) - Pullup Typical data is non-monotonic NOTE (line 34792) - Pullup Minimum data is non-monotonic WARNING - Model Model46: GND Clamp : Typical value never becomes zero WARNING - Model Model46: GND Clamp : Maximum value never becomes zero WARNING - Model Model47: POWER Clamp : Typical value never becomes zero WARNING - Model Model47: POWER Clamp : Minimum value never becomes zero WARNING - Model Model47: POWER Clamp : Maximum value never becomes zero NOTE (line 35483) - Pulldown Maximum data is non-monotonic NOTE (line 35486) - Pulldown Typical data is non-monotonic NOTE (line 35490) - Pulldown Minimum data is non-monotonic NOTE (line 35580) - Pullup Typical data is non-monotonic NOTE (line 35580) - Pullup Maximum data is non-monotonic NOTE (line 35581) - Pullup Minimum data is non-monotonic WARNING - Model Model48: POWER Clamp : Typical value never becomes zero WARNING - Model Model48: POWER Clamp : Minimum value never becomes zero WARNING - Model Model48: POWER Clamp : Maximum value never becomes zero NOTE (line 39926) - Pulldown Maximum data is non-monotonic NOTE (line 39929) - Pulldown Typical data is non-monotonic NOTE (line 39933) - Pulldown Minimum data is non-monotonic NOTE (line 40023) - Pullup Typical data is non-monotonic NOTE (line 40023) - Pullup Maximum data is non-monotonic NOTE (line 40024) - Pullup Minimum data is non-monotonic WARNING - Model Model49: POWER Clamp : Typical value never becomes zero WARNING - Model Model49: POWER Clamp : Minimum value never becomes zero WARNING - Model Model49: POWER Clamp : Maximum value never becomes zero NOTE (line 44369) - Pulldown Maximum data is non-monotonic NOTE (line 44372) - Pulldown Typical data is non-monotonic NOTE (line 44376) - Pulldown Minimum data is non-monotonic NOTE (line 44466) - Pullup Typical data is non-monotonic NOTE (line 44466) - Pullup Maximum data is non-monotonic NOTE (line 44467) - Pullup Minimum data is non-monotonic WARNING - Model Model49: GND Clamp : Typical value never becomes zero WARNING - Model Model49: GND Clamp : Maximum value never becomes zero WARNING - Model Model53: POWER Clamp : Typical value never becomes zero WARNING - Model Model53: POWER Clamp : Minimum value never becomes zero WARNING - Model Model53: POWER Clamp : Maximum value never becomes zero NOTE (line 49476) - Pulldown Maximum data is non-monotonic NOTE (line 49479) - Pulldown Typical data is non-monotonic NOTE (line 49483) - Pulldown Minimum data is non-monotonic NOTE (line 49573) - Pullup Typical data is non-monotonic NOTE (line 49573) - Pullup Maximum data is non-monotonic NOTE (line 49574) - Pullup Minimum data is non-monotonic WARNING - Model Model54: POWER Clamp : Typical value never becomes zero WARNING - Model Model54: POWER Clamp : Minimum value never becomes zero WARNING - Model Model54: POWER Clamp : Maximum value never becomes zero NOTE (line 53919) - Pulldown Maximum data is non-monotonic NOTE (line 53922) - Pulldown Typical data is non-monotonic NOTE (line 53926) - Pulldown Minimum data is non-monotonic NOTE (line 54016) - Pullup Typical data is non-monotonic NOTE (line 54016) - Pullup Maximum data is non-monotonic NOTE (line 54017) - Pullup Minimum data is non-monotonic WARNING - Model Model55: POWER Clamp : Typical value never becomes zero WARNING - Model Model55: POWER Clamp : Minimum value never becomes zero WARNING - Model Model55: POWER Clamp : Maximum value never becomes zero NOTE (line 58362) - Pulldown Maximum data is non-monotonic NOTE (line 58365) - Pulldown Typical data is non-monotonic NOTE (line 58369) - Pulldown Minimum data is non-monotonic NOTE (line 58459) - Pullup Typical data is non-monotonic NOTE (line 58459) - Pullup Maximum data is non-monotonic NOTE (line 58460) - Pullup Minimum data is non-monotonic WARNING - Model Model55: GND Clamp : Typical value never becomes zero WARNING - Model Model55: GND Clamp : Maximum value never becomes zero WARNING - Model Model56: POWER Clamp : Typical value never becomes zero WARNING - Model Model56: POWER Clamp : Minimum value never becomes zero WARNING - Model Model56: POWER Clamp : Maximum value never becomes zero NOTE (line 62809) - Pulldown Maximum data is non-monotonic NOTE (line 62811) - Pulldown Typical data is non-monotonic NOTE (line 62814) - Pulldown Minimum data is non-monotonic NOTE (line 62902) - Pullup Maximum data is non-monotonic NOTE (line 62903) - Pullup Typical data is non-monotonic NOTE (line 62905) - Pullup Minimum data is non-monotonic NOTE (line 63620) - Pulldown Maximum data is non-monotonic NOTE (line 63622) - Pulldown Typical data is non-monotonic NOTE (line 63625) - Pulldown Minimum data is non-monotonic NOTE (line 63713) - Pullup Maximum data is non-monotonic NOTE (line 63714) - Pullup Typical data is non-monotonic NOTE (line 63716) - Pullup Minimum data is non-monotonic NOTE (line 64431) - Pulldown Maximum data is non-monotonic NOTE (line 64433) - Pulldown Typical data is non-monotonic NOTE (line 64436) - Pulldown Minimum data is non-monotonic NOTE (line 64524) - Pullup Maximum data is non-monotonic NOTE (line 64525) - Pullup Typical data is non-monotonic NOTE (line 64527) - Pullup Minimum data is non-monotonic WARNING - Model Model58: GND Clamp : Typical value never becomes zero WARNING - Model Model58: GND Clamp : Maximum value never becomes zero WARNING - Model Model59: POWER Clamp : Typical value never becomes zero WARNING - Model Model59: POWER Clamp : Minimum value never becomes zero WARNING - Model Model59: POWER Clamp : Maximum value never becomes zero NOTE (line 65238) - Pulldown Maximum data is non-monotonic NOTE (line 65241) - Pulldown Typical data is non-monotonic NOTE (line 65245) - Pulldown Minimum data is non-monotonic NOTE (line 65335) - Pullup Typical data is non-monotonic NOTE (line 65335) - Pullup Maximum data is non-monotonic NOTE (line 65336) - Pullup Minimum data is non-monotonic WARNING - Model Model60: POWER Clamp : Typical value never becomes zero WARNING - Model Model60: POWER Clamp : Minimum value never becomes zero WARNING - Model Model60: POWER Clamp : Maximum value never becomes zero NOTE (line 69681) - Pulldown Maximum data is non-monotonic NOTE (line 69684) - Pulldown Typical data is non-monotonic NOTE (line 69688) - Pulldown Minimum data is non-monotonic NOTE (line 69778) - Pullup Typical data is non-monotonic NOTE (line 69778) - Pullup Maximum data is non-monotonic NOTE (line 69779) - Pullup Minimum data is non-monotonic WARNING - Model Model61: POWER Clamp : Typical value never becomes zero WARNING - Model Model61: POWER Clamp : Minimum value never becomes zero WARNING - Model Model61: POWER Clamp : Maximum value never becomes zero NOTE (line 74124) - Pulldown Maximum data is non-monotonic NOTE (line 74127) - Pulldown Typical data is non-monotonic NOTE (line 74131) - Pulldown Minimum data is non-monotonic NOTE (line 74221) - Pullup Typical data is non-monotonic NOTE (line 74221) - Pullup Maximum data is non-monotonic NOTE (line 74222) - Pullup Minimum data is non-monotonic WARNING - Model Model61: GND Clamp : Typical value never becomes zero WARNING - Model Model61: GND Clamp : Maximum value never becomes zero NOTE (line 78868) - Pulldown Maximum data is non-monotonic NOTE (line 78870) - Pulldown Typical data is non-monotonic NOTE (line 78873) - Pulldown Minimum data is non-monotonic NOTE (line 79589) - Pulldown Maximum data is non-monotonic NOTE (line 79591) - Pulldown Typical data is non-monotonic NOTE (line 79594) - Pulldown Minimum data is non-monotonic NOTE (line 80311) - Pulldown Maximum data is non-monotonic NOTE (line 80313) - Pulldown Typical data is non-monotonic NOTE (line 80316) - Pulldown Minimum data is non-monotonic NOTE (line 80401) - Pullup Maximum data is non-monotonic NOTE (line 80402) - Pullup Typical data is non-monotonic NOTE (line 80403) - Pullup Minimum data is non-monotonic NOTE (line 80561) - GND Clamp Minimum data is non-monotonic NOTE (line 80566) - GND Clamp Typical data is non-monotonic NOTE (line 80567) - GND Clamp Maximum data is non-monotonic NOTE (line 81130) - Pulldown Maximum data is non-monotonic NOTE (line 81132) - Pulldown Typical data is non-monotonic NOTE (line 81135) - Pulldown Minimum data is non-monotonic NOTE (line 81220) - Pullup Maximum data is non-monotonic NOTE (line 81221) - Pullup Typical data is non-monotonic NOTE (line 81222) - Pullup Minimum data is non-monotonic WARNING - Model Model68: POWER Clamp : Typical value never becomes zero WARNING - Model Model68: POWER Clamp : Minimum value never becomes zero WARNING - Model Model68: POWER Clamp : Maximum value never becomes zero NOTE (line 82047) - Pulldown Maximum data is non-monotonic NOTE (line 82049) - Pulldown Typical data is non-monotonic NOTE (line 82052) - Pulldown Minimum data is non-monotonic NOTE (line 82140) - Pullup Maximum data is non-monotonic NOTE (line 82141) - Pullup Typical data is non-monotonic NOTE (line 82143) - Pullup Minimum data is non-monotonic NOTE (line 82858) - Pulldown Maximum data is non-monotonic NOTE (line 82860) - Pulldown Typical data is non-monotonic NOTE (line 82863) - Pulldown Minimum data is non-monotonic NOTE (line 82951) - Pullup Maximum data is non-monotonic NOTE (line 82952) - Pullup Typical data is non-monotonic NOTE (line 82954) - Pullup Minimum data is non-monotonic NOTE (line 83669) - Pulldown Maximum data is non-monotonic NOTE (line 83671) - Pulldown Typical data is non-monotonic NOTE (line 83674) - Pulldown Minimum data is non-monotonic NOTE (line 83762) - Pullup Maximum data is non-monotonic NOTE (line 83763) - Pullup Typical data is non-monotonic NOTE (line 83765) - Pullup Minimum data is non-monotonic WARNING - Model Model70: GND Clamp : Typical value never becomes zero WARNING - Model Model70: GND Clamp : Maximum value never becomes zero WARNING - Model Model71: POWER Clamp : Typical value never becomes zero WARNING - Model Model71: POWER Clamp : Minimum value never becomes zero WARNING - Model Model71: POWER Clamp : Maximum value never becomes zero NOTE (line 84480) - Pulldown Maximum data is non-monotonic NOTE (line 84482) - Pulldown Typical data is non-monotonic NOTE (line 84485) - Pulldown Minimum data is non-monotonic NOTE (line 84570) - Pullup Maximum data is non-monotonic NOTE (line 84571) - Pullup Typical data is non-monotonic NOTE (line 84574) - Pullup Minimum data is non-monotonic NOTE (line 85291) - Pulldown Maximum data is non-monotonic NOTE (line 85293) - Pulldown Typical data is non-monotonic NOTE (line 85296) - Pulldown Minimum data is non-monotonic NOTE (line 85381) - Pullup Maximum data is non-monotonic NOTE (line 85382) - Pullup Typical data is non-monotonic NOTE (line 85385) - Pullup Minimum data is non-monotonic WARNING - Model Model72: GND Clamp : Typical value never becomes zero WARNING - Model Model72: GND Clamp : Maximum value never becomes zero NOTE (line 86102) - Pulldown Maximum data is non-monotonic NOTE (line 86104) - Pulldown Typical data is non-monotonic NOTE (line 86107) - Pulldown Minimum data is non-monotonic NOTE (line 86192) - Pullup Maximum data is non-monotonic NOTE (line 86193) - Pullup Typical data is non-monotonic NOTE (line 86196) - Pullup Minimum data is non-monotonic WARNING - Model Model74: POWER Clamp : Typical value never becomes zero WARNING - Model Model74: POWER Clamp : Minimum value never becomes zero WARNING - Model Model74: POWER Clamp : Maximum value never becomes zero WARNING (line 87004) - Model Model75: C_comp min value is not the smallest value listed WARNING (line 87004) - Model Model75: C_comp max value is not the largest value listed WARNING - Model Model76: POWER Clamp : Typical value never becomes zero WARNING - Model Model76: POWER Clamp : Minimum value never becomes zero WARNING - Model Model76: POWER Clamp : Maximum value never becomes zero NOTE (line 87340) - Pulldown Maximum data is non-monotonic NOTE (line 87342) - Pulldown Typical data is non-monotonic NOTE (line 87345) - Pulldown Minimum data is non-monotonic NOTE (line 87430) - Pullup Maximum data is non-monotonic NOTE (line 87431) - Pullup Typical data is non-monotonic NOTE (line 87434) - Pullup Minimum data is non-monotonic NOTE (line 88151) - Pulldown Maximum data is non-monotonic NOTE (line 88153) - Pulldown Typical data is non-monotonic NOTE (line 88156) - Pulldown Minimum data is non-monotonic NOTE (line 88241) - Pullup Maximum data is non-monotonic NOTE (line 88242) - Pullup Typical data is non-monotonic NOTE (line 88245) - Pullup Minimum data is non-monotonic NOTE (line 88962) - Pulldown Maximum data is non-monotonic NOTE (line 88964) - Pulldown Typical data is non-monotonic NOTE (line 88967) - Pulldown Minimum data is non-monotonic NOTE (line 89052) - Pullup Maximum data is non-monotonic NOTE (line 89053) - Pullup Typical data is non-monotonic NOTE (line 89056) - Pullup Minimum data is non-monotonic WARNING - Model Model78: GND Clamp : Typical value never becomes zero WARNING - Model Model78: GND Clamp : Maximum value never becomes zero WARNING - Model Model79: GND Clamp : Minimum value never becomes zero NOTE (line 89792) - POWER Clamp Typical data is non-monotonic NOTE (line 89792) - POWER Clamp Minimum data is non-monotonic NOTE (line 89795) - POWER Clamp Maximum data is non-monotonic WARNING - Model Model80: POWER Clamp : Typical value never becomes zero WARNING - Model Model80: POWER Clamp : Minimum value never becomes zero WARNING - Model Model80: POWER Clamp : Maximum value never becomes zero WARNING - Model Model82: GND Clamp : Typical value never becomes zero WARNING - Model Model82: GND Clamp : Maximum value never becomes zero WARNING - Model Model83: POWER Clamp : Typical value never becomes zero WARNING - Model Model83: POWER Clamp : Minimum value never becomes zero WARNING - Model Model83: POWER Clamp : Maximum value never becomes zero WARNING - Model Model84: GND Clamp : Typical value never becomes zero WARNING - Model Model84: GND Clamp : Maximum value never becomes zero WARNING (line 91180) - Typ value is not in between Min and Max WARNING (line 91180) - Model Model86: C_comp min value is not the smallest value listed NOTE (line 91201) - Pulldown Maximum data is non-monotonic NOTE (line 91203) - Pulldown Typical data is non-monotonic NOTE (line 91206) - Pulldown Minimum data is non-monotonic NOTE (line 91279) - Pullup Minimum data is non-monotonic NOTE (line 91283) - Pullup Maximum data is non-monotonic NOTE (line 91286) - Pullup Typical data is non-monotonic NOTE (line 91451) - GND Clamp Minimum data is non-monotonic NOTE (line 91456) - GND Clamp Typical data is non-monotonic NOTE (line 91457) - GND Clamp Maximum data is non-monotonic WARNING (line 91993) - Typ value is not in between Min and Max WARNING (line 91993) - Model Model87: C_comp min value is not the smallest value listed NOTE (line 92014) - Pulldown Maximum data is non-monotonic NOTE (line 92016) - Pulldown Typical data is non-monotonic NOTE (line 92019) - Pulldown Minimum data is non-monotonic NOTE (line 92092) - Pullup Minimum data is non-monotonic NOTE (line 92096) - Pullup Maximum data is non-monotonic NOTE (line 92099) - Pullup Typical data is non-monotonic NOTE (line 92264) - GND Clamp Minimum data is non-monotonic NOTE (line 92270) - GND Clamp Typical data is non-monotonic NOTE (line 92270) - GND Clamp Maximum data is non-monotonic WARNING (line 92806) - Typ value is not in between Min and Max WARNING (line 92806) - Model Model88: C_comp min value is not the smallest value listed NOTE (line 92827) - Pulldown Maximum data is non-monotonic NOTE (line 92829) - Pulldown Typical data is non-monotonic NOTE (line 92832) - Pulldown Minimum data is non-monotonic NOTE (line 92905) - Pullup Minimum data is non-monotonic NOTE (line 92909) - Pullup Maximum data is non-monotonic NOTE (line 92912) - Pullup Typical data is non-monotonic NOTE (line 93077) - GND Clamp Minimum data is non-monotonic NOTE (line 93082) - GND Clamp Typical data is non-monotonic NOTE (line 93083) - GND Clamp Maximum data is non-monotonic WARNING - Model Model89: POWER Clamp : Typical value never becomes zero WARNING - Model Model89: POWER Clamp : Minimum value never becomes zero WARNING - Model Model89: POWER Clamp : Maximum value never becomes zero NOTE (line 93745) - Pulldown Maximum data is non-monotonic NOTE (line 93747) - Pulldown Typical data is non-monotonic NOTE (line 93750) - Pulldown Minimum data is non-monotonic NOTE (line 93835) - Pullup Maximum data is non-monotonic NOTE (line 93836) - Pullup Typical data is non-monotonic NOTE (line 93839) - Pullup Minimum data is non-monotonic NOTE (line 94556) - Pulldown Maximum data is non-monotonic NOTE (line 94558) - Pulldown Typical data is non-monotonic NOTE (line 94561) - Pulldown Minimum data is non-monotonic NOTE (line 94646) - Pullup Maximum data is non-monotonic NOTE (line 94647) - Pullup Typical data is non-monotonic NOTE (line 94650) - Pullup Minimum data is non-monotonic WARNING - Model Model90: GND Clamp : Typical value never becomes zero WARNING - Model Model90: GND Clamp : Maximum value never becomes zero NOTE (line 95367) - Pulldown Maximum data is non-monotonic NOTE (line 95369) - Pulldown Typical data is non-monotonic NOTE (line 95372) - Pulldown Minimum data is non-monotonic NOTE (line 95457) - Pullup Maximum data is non-monotonic NOTE (line 95458) - Pullup Typical data is non-monotonic NOTE (line 95461) - Pullup Minimum data is non-monotonic WARNING - Model Model95: POWER Clamp : Typical value never becomes zero WARNING - Model Model95: POWER Clamp : Minimum value never becomes zero WARNING - Model Model95: POWER Clamp : Maximum value never becomes zero NOTE (line 96798) - Pulldown Maximum data is non-monotonic NOTE (line 96801) - Pulldown Typical data is non-monotonic NOTE (line 96805) - Pulldown Minimum data is non-monotonic NOTE (line 96895) - Pullup Typical data is non-monotonic NOTE (line 96895) - Pullup Maximum data is non-monotonic NOTE (line 96896) - Pullup Minimum data is non-monotonic WARNING - Model Model96: POWER Clamp : Typical value never becomes zero WARNING - Model Model96: POWER Clamp : Minimum value never becomes zero WARNING - Model Model96: POWER Clamp : Maximum value never becomes zero NOTE (line 101241) - Pulldown Maximum data is non-monotonic NOTE (line 101244) - Pulldown Typical data is non-monotonic NOTE (line 101248) - Pulldown Minimum data is non-monotonic NOTE (line 101338) - Pullup Typical data is non-monotonic NOTE (line 101338) - Pullup Maximum data is non-monotonic NOTE (line 101339) - Pullup Minimum data is non-monotonic WARNING - Model Model97: POWER Clamp : Typical value never becomes zero WARNING - Model Model97: POWER Clamp : Minimum value never becomes zero WARNING - Model Model97: POWER Clamp : Maximum value never becomes zero NOTE (line 105684) - Pulldown Maximum data is non-monotonic NOTE (line 105687) - Pulldown Typical data is non-monotonic NOTE (line 105691) - Pulldown Minimum data is non-monotonic NOTE (line 105781) - Pullup Typical data is non-monotonic NOTE (line 105781) - Pullup Maximum data is non-monotonic NOTE (line 105782) - Pullup Minimum data is non-monotonic WARNING - Model Model97: GND Clamp : Typical value never becomes zero WARNING - Model Model97: GND Clamp : Maximum value never becomes zero WARNING - Combined Pulldown for Model: Model97 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model96 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model95 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model88 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model87 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model86 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model67 Typical data is non-monotonic WARNING - Combined Pulldown for Model: Model67 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model67 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model66 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model65 Typical data is non-monotonic WARNING - Combined Pulldown for Model: Model65 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model65 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model61 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model60 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model59 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model55 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model54 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model53 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model49 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model48 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model47 Maximum data is non-monotonic ERROR - Model Model32: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture]=0V has TYP column DC endpoints of 0.00V and 1.19v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 0.98V), a difference of 0.00% and 21.94%, respectively. ERROR - Model Model32: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture]=1.8V has TYP column DC endpoints of 0.63V and 1.80v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.88V and 1.80V), a difference of 27.06% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model32 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model32 Maximum data is non-monotonic ERROR - Model Model32: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=0V has MAX column DC endpoints of 0.00V and 1.38v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 1.15V), a difference of 0.00% and 20.19%, respectively. ERROR - Model Model32: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=1.89V has MAX column DC endpoints of 0.53V and 1.89v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.84V and 1.89V), a difference of 29.38% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model31 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model31 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model28 Typical data is non-monotonic WARNING - Combined Pulldown for Model: Model28 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model28 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model27 Typical data is non-monotonic WARNING - Combined Pulldown for Model: Model27 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model23 Maximum data is non-monotonic ERROR - Model Model22: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture]=0V has TYP column DC endpoints of 0.00V and 1.19v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 0.98V), a difference of 0.00% and 21.94%, respectively. ERROR - Model Model22: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture]=1.8V has TYP column DC endpoints of 0.63V and 1.80v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.88V and 1.80V), a difference of 27.06% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model22 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model22 Maximum data is non-monotonic ERROR - Model Model22: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=0V has MAX column DC endpoints of 0.00V and 1.38v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 1.15V), a difference of 0.00% and 20.19%, respectively. ERROR - Model Model22: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=1.89V has MAX column DC endpoints of 0.53V and 1.89v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.84V and 1.89V), a difference of 29.38% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model21 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model21 Maximum data is non-monotonic WARNING - Combined Pullup for Model: Model20 Maximum data is non-monotonic WARNING - Combined Pullup for Model: Model19 Maximum data is non-monotonic WARNING - Combined Pullup for Model: Model18 Maximum data is non-monotonic WARNING - Combined Pulldown for Model: Model14 Typical data is non-monotonic WARNING - Combined Pulldown for Model: Model14 Minimum data is non-monotonic WARNING - Combined Pulldown for Model: Model14 Maximum data is non-monotonic ERROR - Model Model10: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture]=0V has TYP column DC endpoints of 0.00V and 1.19v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 0.98V), a difference of 0.00% and 21.94%, respectively. ERROR - Model Model10: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture]=1.8V has TYP column DC endpoints of 0.63V and 1.80v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.88V and 1.80V), a difference of 27.06% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model10 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model10 Maximum data is non-monotonic ERROR - Model Model10: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=0V has MAX column DC endpoints of 0.00V and 1.38v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 1.15V), a difference of 0.00% and 20.19%, respectively. ERROR - Model Model10: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=1.89V has MAX column DC endpoints of 0.53V and 1.89v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.84V and 1.89V), a difference of 29.38% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model9 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model9 Maximum data is non-monotonic ERROR - Model Model5: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture]=0V has TYP column DC endpoints of 0.00V and 1.19v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 0.98V), a difference of 0.00% and 21.94%, respectively. ERROR - Model Model5: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture]=1.8V has TYP column DC endpoints of 0.63V and 1.80v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.88V and 1.80V), a difference of 27.06% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model5 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model5 Maximum data is non-monotonic ERROR - Model Model5: The [Rising Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=0V has MAX column DC endpoints of 0.00V and 1.38v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.00V and 1.15V), a difference of 0.00% and 20.19%, respectively. ERROR - Model Model5: The [Falling Waveform] with [R_fixture]=50 Ohms and [V_fixture_max]=1.89V has MAX column DC endpoints of 0.53V and 1.89v, but an equivalent load applied to the model's I-V tables yields different voltages ( 0.84V and 1.89V), a difference of 29.38% and 0.00%, respectively. WARNING - Combined Pulldown for Model: Model4 Minimum data is non-monotonic WARNING - Combined Pullup for Model: Model4 Maximum data is non-monotonic WARNING - CMPT 'omap3530cbb': Lpkg MIN value -0.279127nH not within expected range (0nH, 1000nH) WARNING - CMPT 'omap3530cbb': Cpkg MIN value -0.689568pF not within expected range (0pF, 1000pF) Errors : 16 Warnings: 182 File Failed