Hi Dmitri
The ADC12J1600EVM Rev E3 schematics are available at the link below. The only difference between the ADC12J4000 Rev. E3 and the ADC12J1600EVM Rev. E3 is the ADC part number.
ADC12J4000EVM Schematic Prints. Rev E3.PDF
Best regards,
Jim…
Other Parts Discussed in Thread: ADC12J4000EVM , ADC12J4000 , DAC38J84 I am using the ADC12J4000EVM together with the TSW14J56EVM. The SW I use is High Speed Data converter Pro 2.6, together with the ADC12J400EVM GUI version 1.3
The TSW has enough memory…
Hi Bharath
I'm reviewing your register settings now.
Are you using the ADC12J4000EVM or EVM design, or is it significantly different? If it is the same as the EVM design, is your JESD204B receive firmware compensating for the polarity inversion in…
Hi Walter
The ADC12J4000EVM clock architecture was optimized for ADC sample rate flexibility with minimal changes to other settings. For a fixed sample rate and/or multi-converter application a better architecture would be what you are proposing. One…
Hi Kl
Regarding your questions:
The absolute phase of this signal is less important than the quality of the clock waveform at the receiver. To keep the normal P/N polarity would have meant adding vias and routing the signal on another layer. To…
Other Parts Discussed in Thread: ADC12J4000 , ADC16DX370 , LM15851 , ADC12J4000EVM Hello.
I wnat to know what is the meaning of this sentence in user guide.
The product which i saw is like this :
ADC12J4000 Evaluation Module : http://www.ti…
Hi Jeff
The most straightforward synchronization approach is described in this TI Design ( http://www.ti.com/tool/TIDA-00467 ). This uses the newer Rev A version of the ADC12J4000EVM which has the necessary connections from the LMK04828 outputs to the…
Hi Valentin
If you are capturing data for the purpose of evaluating the ADC12J4000 device, we recommend you use the ADC12J4000EVM along with either the TSW14J56EVM or TSW14J10EVM+Xilinx-VC707 for data capture. Either of these platforms can be used with…
Hi Itai
Section 8 of the ADC12J4000 datasheet gives a little more guidance regarding input signal conditioning. Section 8.2.1 shows a typical high frequency RF input application while section 8.2.2 shows an oscilloscope application.
Here are the 3…
Other Parts Discussed in Thread: ADC12J4000 I am using the ADC12J4000EVM together with the TSW14J56EVM . The SW I use is High Speed Data converter Pro 2.6, together with the ADC12J400EVM GUI version 1.3
I would like to test the ADC12J4000 in a computerized…