Part Number: BQ34210-Q1
Dear team,
The systems of our customer usually discharge about 10mA. It is written to the datasheet with "for Rarely Discharged Batteries", does even such a system not have any problem?
My customer uses LiFePO4. Is this gas…
Part Number: BQ34210-Q1 Other Parts Discussed in Thread: BQ34110 , I am current using BQ34110 to monitor my IoT device battery on job site. There are multiple chemicals, such as, lead-acid and NiCd. I am also interested to replace it by BQ34210-Q1 on…
Part Number: BQ34210-Q1 Other Parts Discussed in Thread: BQ27Z561-R2 Hell o expert,
M ay I have your confirm if BQ34210-Q1 could support 2V~3.65V LiFePO4 battery with 1.4A output? Or we have better solution for it? Thanks a lot!
Best regards,
Ann…
Hi Fleming,
All the procedure you need is in user guide SLUUBR7 Quickstart Guide for bq34210-Q1, refer to this guide for changing the parameters, remember to unseal the device and enter Configuration Update Mode as stated in the guide.
Best Regards…
Part Number: BQ34210-Q1 Other Parts Discussed in Thread: CC2652R , BQSTUDIO , EV2400 , BQ34Z100-G1 , BQ27426 , BQ27220 Hallo,
I have a BQ34210-Q1 on a custom board with a CC2652R.
I'm trying to get the StateOfCharge and StateOfHealth from this battery…
Part Number: BQ34210-Q1 Hi,
I am trying to put the device into shutdown mode before that, I am making the device to Unseal mode. Once I send the Unseal commands, the BQ chip is not responding always the I2C busy error code is returning. When unseal…
Part Number: BQ34210-Q1 Other Parts Discussed in Thread: BQSTUDIO 1). What does Coulomb counter offset(CC offset) mean and what would be the expected offset value?, when should we do this calibration?(Is it while charging or discharging)
2). What…
Part Number: BQ34210-Q1 I'm planning to use BQ34210IPWRQ1 fuel gauge in my design in system configuration along with battery charger.
Design details are as below,
1. 1 cell 3.7V Li-ion battery
2. Charge current @400mA
3. Charger used for charging…
Part Number: BQ34210-Q1 Other Parts Discussed in Thread: BQSTUDIO , GPCCEDV , EV2400 Hi Dear Reader(s),
From
bq34210-Q1 Technical Reference Manual - bq34210_sluube8.pdf.
I have located this,
"2.8.1 Battery Profile Storage and Selection
The…
According to the TRM and your configurations, the bq34210-Q1 device enters RELAXATION mode from CHARGE mode if Current() goes below Quit Current (40mA) for a period of Charge Relax Time (60s). It also enters RELAXATION mode from DISCHARGE mode if Current…