Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79616-Q1 , BQ34Z100-R2 Tool/software: Hi, I would like to know where I can get all the Functional Safety documentation of the following IC
BQ79656-Q1
BQ79616-Q1
BQ34Z100-R2
Thank you…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ76952 Hello Sir:
We are considering BQ79656-Q1 in our BMS.
I' d like to confirm about GND position for IC.
According to Datasheet Fig.10-1.(P187), GND position is under side of Rsense…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79600-Q1 , BQ79616-Q1 ,
"Is bq79600 only used for stack devices? When I use one bq79656, can I connect it to bq79600?"
Part Number: BQ79656-Q1 Dear Ti Team,
We are using bq79656, in same we are using shunt based current sensing. we have observed that there is error in current reading above 20/30A, it is currently giving us error of 1 to 1.8 A on value above 100A.…
Part Number: BQ79656-Q1 Hi,
We Have Used BQ79656-Q1 Automotive BMS Controller in My Project,
This controller Datasheet have not Mentioned any pin for CHG FET on /off & DSG FET on/off.
Is that means host microcontroller will control the CHG/DSG…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79616 Tool/software: Hi all,
I am working on BQ79656-Q1 IC the problem is When I give 3V only to 16th (VS16) cell then the 16th cell reads 2.4 2.3 like that
but when i connect pack of 16 cell…
Part Number: BQ79656-Q1 Tool/software:
Hello,
I'm using the BQ79656 with an NXP S32K3 series microcontroller.
I'm facing an issue, where after first time Power on reset all Cell voltage, temperature, and other parameters read as zero. However, after…
Part Number: BQ79656-Q1
Tool/software:
Hi,
My questions are in 48V BMS to switch the Power BUS:
1. Which is the better and Efficient method of Bidirectional switching High Power Bus, Positive side Common Source or negative side Common Drain Using…
Part Number: BQ79656-Q1 Tool/software:
Hi,
I’m experiencing an issue with my UART buffer where the UART buffer sometimes gets filled with zeroes or partial zeroes. The correct data is received, but the occurrence of zeroes is inconsistent. I'm Using…