Part Number: BQ79656-Q1 Hi,
I'm using the 4 BQ79656 EVM for our application, which are connected with the daisy chain network.
is there any length restriction for the daisy chain wires?
and is daisy chain wire required the shielding as well? because…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79656EVM-021 Hi All,
I'm using BQ79656EVM-021 and BQ79600EVM-030 (Bridge evaluation board)
BQ79656EVM-021 evaluation board is connected with BQ79600EVM-030 on Daisy Chain protocol
I want…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79616-Q1 Hi all,
i am working on BQ79656-Q1 and when i use GPIO1-GPIO8 as a only ADC than i get only results on GPIO1-GPIO3 and not getting results on GPIO4-GPIO8
Below is my configuration…
Part Number: BQ79656-Q1 Hello Sir:
We have schematic review request, would you please help to add me in friend.
And I will provide the schematic for you.
Looking forward your feedback.
Thanks a lot.
Part Number: BQ79656-Q1
Hello,
I am an electrical lead for the Virginia Formula SAE team and we are working with the TI BQ79656 chips. We are attempting to design a custom BMS for an accumulator made up of 100 cells in series. Our battery configuration…
Part Number: BQ79656-Q1 Hi,
I am using the BQ79656, in that when odd balancing is ON, the fluctuations in Cell voltage is observed in respective cell.
Is there any provision in AFE to avoid the fluctuations in cell voltage.
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79616
Hello,
I am using two BQ79656 in a stack configuration to make a 32S pack. This is an image of BQ79616 IC, but since the stack operation is the same I am showing this as a reference…
Part Number: BQ79656-Q1 Other Parts Discussed in Thread: BQ79616 Hi Team,
My customer is asking for our BQ79600, BQ79616, BQ79656 daisy chain MCU demo code for software evaluation. Can you send me by email? They are doing 48V BMS
Thanks,
Ha…
Part Number: BQ79656-Q1 Hello TI Support,
I see from the BQ79656 datasheet that the BQ79656 has a current sense and a Bus Bar feature. Is it possible to use the Bus Bar feature to measure current instead of using SRP/SRN to measure current? If not,…
Part Number: BQ79656-Q1 Hello,
we are facing a problem regarding the OVUV/OTUT DAC check and the according safety measures (202, 203, 204, 205, 208, 209 and 210). The measured misc values from the Aux ADC are always 0x8000 (invalid or unused) for…