Part Number: DDC232 Other Parts Discussed in Thread: OPA350 , OPA328 Hello,
TI recommends to use an op-amp to buffer the reference voltage for the DDC232.
The OPA350 is suggested, are there better buffer amplifiers that you recommend that are newer devices…
I have posted a message here:
https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/1341543/tlv761-supplying-appropriate-voltages-from-5v-fpga-for-ddc232/5110230#5110230
However, an important part of this is understanding…
Part Number: TLV761 Other Parts Discussed in Thread: DDC232 We have a custom-designed photodiode readout board built around a DDC232. We have been supplying power directly to this board but need to move to supplying it from the FPGA we use for the readout…
Part Number: DDC232 Hello! I have been testing the DDC232 board with a short molex cable (~10cm), a long molex cable (~50cm) and a usb C. Everything else remains the same, but when switching the cables to acquire data I have came across some issues with…
Part Number: DDC232 I have a question about the DDC232CK.
According to datasheet P3, The DDC232CK is designed to use a system clock (CLK) of 10MHz or 40MHz.
Is it okay to use the DDC232CK system clock (CLK) at 5MHz or 20MHz like the DDC232C?
Part Number: DDC232 I have a question about the DDC232CK. About Table 9 on P16 of the specification "32-Channel, Current-Input Analog-to-Digital Converter" What is the value of tmraz if Clk_4x = 1?
Part Number: DDC232
Hi TI Team,
Thank you for your support.
I have a question about DDC232CKZXGT (A/D converter)
We are debugging our prototype board. But DDC232CKZXGT is unexpected input operation.
We could be misunderstood, or We didn't put important…
Part Number: DDC232 Hello!
We are designing an opto-electronic device and we have chosen the DDC232 as an ADC to read data from a photodiode array.
I wanted to ask if it is possible to use the same microcontroller SPI peripheral for configuration and…
Part Number: DDC232 Hi Texas,
I am working on a large memristor crossbar array (32x32) with 32 rows and 32 columns. I want to measure simultaneous current using your DDC architecture.
I require to sense the current range: 200 nA to 5 mA