Part Number: LM3880 Hi team,
Could you tell me about the operation to turn off the power while the IC is operating.
In the following circuit diagram, what kind of motion does FLAG move when VCC is slowly set to 0 V?
First, FLAG 3 is turned off,…
Part Number: LM3880 Other Parts Discussed in Thread: LM3881 Hi Team,
The figure shows LM3880MF-1AE is 30 ms delay.
But table 4 shows 30ms is AB, not AE.
Could you help to check the waveform shows wrong ?
The other questions is we would like to…
Part Number: LM3880 Dear Sir,
We are planning to use LM3880MF-1AA/NOPB in our existing design.
In view of the above we want to know the end of life of the product.
Regards,
Arun P
Part Number: LM3880 Hello,
Does the LM3880 have the ability to change the delays between flag events? I see the datasheet, on Table 1, says the flag timing delay is set at 30 ms. Is this time adjustable at all (without having the factory have to re…
Hi Yihe,
The total current consumed by LM3880 while powered, but when the enable pin is unasserted.
We are trying to optimise battery life.
Kind regards,
EN of LM3880 provides glitch free operation. so it is up to the duration of the 2nd high pulse after EN is de-asserted.
In your char, you list the duration as td or more which will not give a unique answer.
if the duration is less than 2xtd + 120ms…
Part Number: LM3880 Hello,
I am currently having an issue with the LM3880 Spice model. The simulation give an error when I attempt to model the behavior of the power supply (VCC) switching off. I've pasted some images below to help illustrate my problem…
Part Number: LM3880
Hi, Could you tell me about "Datasheet page 15 8.3 Do's and Don'ts" ? 1.What happens inside the device when VCC and EN are connected, causing undefined operation? Please give details of the problem. 2.Customer has connected Vcc…
Part Number: LM3880 Hi team,
My customer is evaluating the LM3880 now, for LM3880, if we turn off VCC first, what will happen about flag 1,2,3? Thanks.