Part Number: LMC6062 Other Parts Discussed in Thread: ADS1119 , LMP7721 , LMP91200
I have designed pH measurement AFE. I am getting significant offset in the measurements using pH sensor. However, if I connect pH calibrator then my circuit generates perfect…
Part Number: LMC6062 Hi
Following my first request on current generator with LM6062 I come back after a long .."COVID" period
As proposed i increase the current of generator by reducing R100 to 68koms instead of 91K
I alsol increase currnt throug…
Part Number: LMC6062 Other Parts Discussed in Thread: OPA277 , LM4040 , LMC6061 Hi
I asked a question to my orignial request
I've done the current generator seen on previous article based on a LMc6062 and reference voltage
The current generator with…
Part Number: LMC6062 Other Parts Discussed in Thread: LM358 ,
Hello !
I am using the LM358 in a circuit for current measurement from 0 to 20mA and I am finding it very accurate the values oscillate quite still with decoupling of 100nF and 10nF…
Part Number: LMC6042 Dear Sirs,
I want to use a LMC6042 as a pH probe front end differential input buffer amp power from a +/-5V power supply. Is this
IC work with a +/-5V power supply with signal GND connect to 0V, and -V (pin 4) connect to -5V of the…
Part Number: LMC6062 Other Parts Discussed in Thread: OPA4187 , OPA2187 , OPA187 Hi Team,
My customer is doing project(upgrade) on medical device and looking for P2P equivalent against MAX478CSA/LT2178CS8.
We have done below comparison (attached) with multiple…
Part Number: LMC6062 Other Parts Discussed in Thread: LM358 , Dear TI Sir :
My customer designed a LM358 circuit.
He found LMC6062 pin to pin LM358.
He use LMC6062 instead of LM358 then PCB is broken.
My customer would like to know , LMC6062 can onstead…
Part Number: LMC6062 Other Parts Discussed in Thread: TINA-TI , LMC6061 Tool/software: TINA-TI or Spice Models I have downloaded spice model for LMC6061 and this OLB file is not opening in LTspice model
Hi Onkar,
Yes, LMC6062 can work, depending on the level of impedance of the probe. LMP7721 is our lowest input bias current device today, with a 5 pA max. spec. at 125C, where LMC6062 has typical input bias current of 10 pA (generally it is easier to…
Other Parts Discussed in Thread: LMC6062 Hi All,
we want use LMC6062 dies which are Al-bonded and mounted on FR4 base material.
We need a recommendation which adhesives are best for die attachment and glob topping.