Part Number: LMP90078 What are the electrical characteristics for this part with Buffer off? The table 8.5 shows only specs with Buffer ON. How can we find the equivalent specs with Buffer OFF?
Other Parts Discussed in Thread: LMP90079 I am using the LMP90079 specifically, but this question applies to the whole series.
On page 5 of the datasheet, it says "Leave the thermal pad floating". However, the reference design on page 60 shows the thermal…
Other Parts Discussed in Thread: LMP90078 , LMP90100 Hi,
Can I use LMP90078 without external clock ?
Now I can not communicate with it through SPI.
Following is my timing chart from LA.
What's the problem could be ?
Thank you~
I write INS 1 = 0x10…
Other Parts Discussed in Thread: LMP90078 , LMP90100 I would like to measure an RTD every period of time (from 1 min to 1 hour) and set the LMP90078 to “Power-Down” mode between measurements.
I’ve got the device to measure in “Single channel…
Hello Hadi,
I have not been able to find any information on whether the scanmode will affect the 50Hz digital filter. Do you see a difference when you try each mode?
The digital filter will filter 50Hz noise only when the LMP90078 is used at 13.74sps…