Part Number: MUX508 Other Parts Discussed in Thread: MUX36D04 , , MUX36S08 , TINA-TI The MUX508 product page has a TINA-TI Spice Model available for download. When I download the .TSM file and open the macro in TINA-TI, it looks like the subcircuit describes…
Part Number: MUX36D04
I need to measure a large number of high precision 100uA current sources using a mux to route each current source in turn to the measuring instrument. Achieving the lowest possible drain ON leakage of the MUX is essential. Maximum…
Part Number: MUX36D04 Other Parts Discussed in Thread: TIPD151 , OPA192 Hi expert,
In TI reference design TIPD151, there are OPA192 working as buffer before MUX36D04.
I'm wondering could I remove OPA192 and directly use MUX36D04 to measure Li-ion battery…
Part Number: MUX36D04 Hi, we're doing some prototyping with the MUX36D04 and realised that the device tends to slowly draw more current over time on the negative rail causing a slow thermal runaway. Anyone had this problem?
Part Number: MUX36D04 Other Parts Discussed in Thread: TPD1E10B09 , TPD1E05U06 Hello,
I need help with a recommendation for addition ESD for a MUX36D04 design.
The mux doesn’t appear to be particularly robust by itself, which is fine, but it will be subjected…
Part Number: MUX36D04 The bxl file for the mux36d04 is not available from the web site. The step works, but no bxl to generate footprint etc
Please upload? :)
Part Number: MUX36D04 Hi Team,
Quick question from my customer.
MUX36D04 has differential on-leakage spec. 15nA max (25C), 500nA max (125C)
Customer is wondering, if DA, DB leakage current is only 3.3nA alone, how come differential leakage can be 500nA…
Part Number: MUX36D04 Hi, We are using MUX36D04 in our circuit and we observed that, when power supply to this switch goes off, the current drawn by the signal input reaches 7mA. Currrently we are using 240E as current limiter. But for how long can this…