Part Number: PGA460-Q1 Other Parts Discussed in Thread: PGA460 Hi Team,
The customer feedback that there are SENSOR defective products that need to be analyzed. The customer wants the PGA460 to output analog waveforms. Please advise how to do it?
Part Number: PGA460 what is the response time for PGA460.
I want to get the distance data continuously , so what is the minimum time requirement for reading two consecutive distance data.
Part Number: PGA460-Q1 Other Parts Discussed in Thread: PGA460 Hi TI,
We want to find a ultrasonic solution use for Automated Parking System? I want to know if the PGA460-Q1 can meet the request or no?
If yes, which informaction support your suggest…
Part Number: PGA460 Team,
at the start the attached INIT sequence is sent, which should put the PGA460 into UART Mode: 0xF0, 0xF8, 0xFC:
The violet trace in the plots is what the PGA 'sees'. Due to the hardware set-up we have the TX/RX lines appear…
Part Number: PGA460 Hi
I am using uart interface between MCU and PGA, I set preset 1 and sending UMR command to get distance measurement response, but PGA response the buffer as 0xFF, below in image is measurement in UART communication, D2 is MCU command…
Part Number: PGA460 Other Parts Discussed in Thread: TUSS4440 Hello! I am looking to drive a few different ultrasonic transducers at different frequencies with a square wave / 50% duty cycle. The Vp-p ranges from 200-500V. The frequency ranges from 100kHz…
Part Number: PGA460-Q1 Other Parts Discussed in Thread: PGA460
Hi there,
I have a problem. I set the circuit and I tried before, both software and hardware are ok. However, something happened and I couldn't read the distance data. PGA IC communicates…
Part Number: PGA460 Hi There,
PGA460 has 4 interfaces – TWI, single line UART, asynchronous TXD/RXD UART and synchronous USART. I want to use the asynchronous UART
Does the async UART allow read and write all registers and implement all functionality…
Part Number: PGA460 Dear Sir.
Now, we build the development ultrasonic module including circuit with PA460, then drive it by uart from Renesas uC. Now our point to check is if
“measurement (command 5)” data has consistency of the Echo dump data(command…
Part Number: PGA460 Other Parts Discussed in Thread: ENERGIA Hi Sir,
My customer want to use PGA460 as ultrasonic TX source for their medical application. They can use EVM GUI and distance detection sample code (ultrasonicCmd(PGA460_USSC.cpp) to send…