Part Number: MSP430FR6047 Other Parts Discussed in Thread: TIDA-01486 Hi,
We were developing a solution with MSP430FR6047 flow meter. The flowmeter board actually works well and we are getting valid flow rates from flow meter module. After taking reference…
Part Number: EVM430-FR6047 Other Parts Discussed in Thread: TINA-TI , TIDA-01486
Hi
I have bought the TIDA-01486 booster pcb and connected it to the EVM-FR6047. However I noticed that I had an ok echo over the transducer (1MHz frequency 80mV pk-2-pk, while…
Part Number: TIDA-01486 Hello,
I am designing TIDA-01486 to get better signal from 1 pair of piezo transducer on metal pipe (clamp on application). Following the below thread:
https://e2e.ti.com/support/microcontrollers/msp-low-power-microcontrollers…
Part Number: EVM430-FR6047 Other Parts Discussed in Thread: TIDA-01486 , EVM430-FR6043 Hello team, I was working on an testbed solution with EVM430-FR6047, that seemed to work well. After moving to a real water pipe (diameter 90mm and wall thickness 8mm…
Part Number: TIDA-01486 Other Parts Discussed in Thread: TINA-TI , THS3095 Hi Team,
I am going through TIDA01486 schematics and designing a PCB. Before that, I try to simulate the OPAMP circuit present on the receiving stage . Here is the simulation c…
Part Number: TIDA-01486 Other Parts Discussed in Thread: EVM430-FR6047 , Hi,
I have a question when i use the EVM430-FR6047 and TIDA-01486,
1,how to generate - 15V voltage?and guarantee the driving ability of -15V?
2,how to chose the voltage of VBIAS?can…
Part Number: TIDA-01486 Hello,
I wanted to use the reference design to begin development on a new project. I would like to know if the provided binary Altium design files could be saved as ASCII Altium design files so they could be converted to a user…
Part Number: TIDA-01486 Other Parts Discussed in Thread: EVM430-FR6047 Hello,
For a clamp-on flowmeter design we use the EVM430-FR6047 together with a self designed sensor with a piezo-disc. We already tested the EVM430-FR6047 stand-alone with these sensors…
Part Number: TIDA-01486 Other Parts Discussed in Thread: EVM430-FR6047 , , MSP430FR6047 , TS5A3357 , THS3095 Hello, I use the EVM430-FR6047 for ultrasonic volume flow measurement and the TIDA-01486 reference design.
After connecting the TIDA-01486 to the EVM430…
Part Number: EVM430-FR6047 Other Parts Discussed in Thread: TIDA-01486 Hi,
When using the TIDA-01486 reference design, which changes are required for the software of the USS software and for the EVM430-FR6047?
Are the files shared in the following thread…