Hello Jack, - TIDA-01568 reference design www.ti.com/.../TIDA-01568 - TIDCEO6 — TIDA-01568 SDK Patch https://www.ti.com/tool/download/TIDCEO6
Jack Cha said: The bootloader is too old from SDK 2.x. But they're unable to change the baseline due to their…
Part Number: TIDA-01568 Other Parts Discussed in Thread: LM3881 Hi,
My customer need assistance.
I understand the relationship between the capacitor C2 and delay of LM3881.
But C2 in s chematic is 10nF, in BOM is 2.2nF. Which one is correct in this reference…
Part Number: AM3352 Other Parts Discussed in Thread: TIDA-01588 , TIDA-01568
The discrete power solution sequence of AM335x, the power up sequence is fine, but the power down sequence violate the first up, last off sequence, the 1.5V(Orange) is later than…
Part Number: AM3354 Other Parts Discussed in Thread: TIDA-01568 Hi Sitara Team
A customer would like to design power supply rail with discrete dcdc/ldo.
So they want to recheck the power supply design. Please review the following sequence and grouped domains…
Hello Yu Boa.
Thank you for the inputs.
I looked at the TIDA-01568 and seems like testing has been done.
You should be able to download the files and follow the routing if that helps.
If you have additional questions, please open a new thread with title…
Hello Sangeetha,
Thank you the inputs.
This reference design demonstrates a validated and cost competitive power sequencing solution for an application processor or a high performance control platform. This design supports 5 different voltage rails, optimized…
In TIDA-01568 I have one sentence that I am not 100% sure about:
6. Kernel: Disable the "RTC Real Time Clocking" configuration.
Can anyone explain exactly what this means?
I'm working on it.
I think I found the problem but not the solution, I am working to verify.
The new power supply design does not control the RTC_PWRONRSTn signal, it is tied to ground. So I think I will have to remove the dependency on the RTC. There…
Part Number: BEAGLEBK Hi all,
This is related to the question I asked a while ago: https://e2e.ti.com/support/processors/f/791/t/769308
We still face the same problem of not being able to flash the initial images using Windows 10. I have asked Microsoft…
Here are some reference designs I found -
#TIDC-WL1835MODCOM8B (Design on WiLink 1835 module)
#TIDC-WL1837MOD-AUDIO-MULTIROOM-CAPE (WiLink cape reference design)
#TIEP-SMART-ENERGY-GATEWAY (Smart home gateway reference design)
#TIDA-01568 (Power sequencing…