Part Number: TMP1826 Tool/software: I am currently using the TMP1826 in bus-powered mode with three sensors connected in parallel to a single SDQ line. Each sensor is assigned a unique short address by connecting the IO pins to Vcc through resistors.…
Part Number: TMP1826 I believe there is a minor discrepancy in the documentation that is causing confusion for our customer.
When setting the device to address 0x00h , Table 8-3 recommends a resistor value less than 6.49k-Ohm , suggesting that 6.49k…
Part Number: TMP1826 Hi TI support Team,
To complete the China customs filing, we need your help to confirm is it a multi-element IC? Does it contain a silicon transducer?
And what's the COD(contury of diffused)of TEXASINSTR^TMP1826NGRR?
Part Number: TMP1826 HI TI Team,
Section 8.3.6 Temperature Alert of the TMP1826 datasheet mentions that "if the IO2/ALERT pin is configured as an alert pin, the alert status is reflected on the pin in supply powered mode."
Could you please clarify…
Part Number: TMP1826 Other Parts Discussed in Thread: SN74LVC1G07 Hi Team,
Posting on behalf of our customer.
I am performing a DC analysis for a new design using the TMP1826NGRR as a 1-Wire temperature sensor, and I have identified a logic level…
Part Number: TMP1826 Tool/software: I found a little problem when reading the user EEPROM. Unfortunately, I don't have an explanation for it. In principle, the transmission of data and temperature works without any problems. So we can discard hardware…
Part Number: TMP1826 Tool/software: Hi,
I'm dealing with a communication issue with the TMP1826 chip. I believe the timing is correct, as the chip reset, device detection, as well as data writing and reading are all working. This is supported by the…
Part Number: TMP1826 Hi,
1. Does TMP1826 have an EEPROM erase command? How to erase?
2. EEPROM programming can only be written according to blocks. After writing one block, must I lock it before writing another? What happens if I don't lock it?
…
Part Number: TMP1826 Tool/software: I'm designing a new product using the TMP1826NGRR and have some questions about the NIST and Calibration process. Some of our clients require more information about the calibration of our devices.
It sounds like TI…