Hi Daisy,
I have attached the TPS2553 CB report, you can refer to it.
1346.E169910-A15-CB-2-Certificate.pdf Certificate-CB-US-34989-UL (1).PDF
Best Regards,
Kuno
Part Number: TPS2116 Other Parts Discussed in Thread: TPS2552 Tool/software: Dear,
I would like to use the TPS2116 to switch between 2 5V power sources of a device that can behave both as USB host (when it has its own power supply) and as USB device…
Part Number: TPS25830A-Q1 Other Parts Discussed in Thread: TPS2552 , TPS25831-Q1 Hi Team,
As title, does the TPS25830A-Q1 and TPS25831-Q1 have the UL Certificate of Compliance IEC 62368-1 like TPS2552?
https://www.ti.com/lit/cr/slvq031/slvq031.pdf…
Part Number: TPS2557 Other Parts Discussed in Thread: TPS2552 Tool/software: I have a circuit with a TPS2557 and a TPS3436BFACA. When I power it normally, it seems to work perfectly. However, when I bypass this circuit and apply 3.3V to the output (which…
Part Number: TPS2552 Hi
I have the questions as below.
1. How long does the current need to remain set to apply the current limit?
2. How does it return after the current limit is activated?
For example, if the current is limited at 520mA…
Part Number: TPS2552 Other Parts Discussed in Thread: TPS25221 Hello team,
i received some questions from my customer about the enable behavior and its threshold variation of TPS2552. I would appreciate if you could give us an advice about it.
(1…
Sir,
1. check TPS2552D datasheet instead of TPS2552. Refer to the 3D model based on TPS2552D datasheet.
2. Don't need power pad as no this pin on the IC.
For TI's policy, I will first click resolved button.
If you have any other concern, contact…
Part Number: TPS2552 Hi,
Could you please tell me each voltage which is generated between ILIM and GND for TPS2552DBVT(SOT-23 package) when the closest 1% resistor(Rilim) which is mentioned in TPS2552 data sheet is connected between ILIM and GND? Additionally…
Part Number: TPS2552 Hi, team.
Please give IEC 60950-1 test report of TPS2552. My customer would like to confirm that it meets the requirements of Annex CC.
And please give TPS2552 UL certificate report.
Best Regards,