Hi
YOu have to enable the fault shutdown slave so that rail of MAC0_HBM_1P2_EN can shut down other rails.
Please refer the quick guide attached, especially on fault response section.
0871.UCD90xxx Quick Guide.pptx
Regards
Yihe
HI
Yes, that is expected.
If you need to shutdown the 0.8V when 12V is gone. then a proper fault response need be set.
Please refer this quick guide(fault response section)/.
63811.UCD90xxx Quick Guide.pptx
Regards
Yihe
HI
If you want to rail 2 is the last rail to be on, you have to set the RAIL2'S turn on dependencies on the rest rails. so that it won't be on until the rest rails are on.
Please refer this quick guide.
1212.UCD90xxx Quick Guide.pptx
Regards …
Hi
I would recommend to take a look this document to understand how device works and how to configure the GUI.
4024.UCD90xxx Quick Guide.pptx
Regards
Yihe
Hello Caleb,
Thanks for reply and information.
FYI : There is a bug in Fusion Designer software.
Fusion GUI - Command Line Tools Overview.pdf
These CLI (command line) are not working. This is main issue.
As per my understanding, these CLI…
Hi
Please refer the quick guide.
if pmbus command is the only way, you have to change the on/off-config to OPERATION mode
and issue operation command to turn on and off.
5148.UCD90xxx Quick Guide.pptx
Regards
Yihe