Part Number: BQ40Z50EVM-561 Other Parts Discussed in Thread: BQ40Z50-R1 , BQ40Z50 , BQSTUDIO , BQ2057C Hi, Im trying to evaluate the Bq40z50-r1 for my Bachelorthesis. I installed the Studio and the Ev2300. I works fine, i think. But as soon as i connect…
Other Parts Discussed in Thread: BQ40Z50-R1 , BQ40Z50EVM-561 Hi,
I have 2 questions on the hardware design for BQ40z50-R1
1. I notice that the EVM BQ40z50EVM-561 uses a normal 10k resistor (CRCW120610K0JNEA) as NTC. Is it ok to do in final production…
Other Parts Discussed in Thread: BQ40Z50-R1 I Just open a new b140z50evm board send from TI, after all the software and hook up were completed I was going down the check list look at all the registers and noted that battery #4 was showing 0 in all address…
Part Number: EV2400 Other Parts Discussed in Thread: BQ40Z50EVM-561 Tool/software: Hello guys,
I bought the BQ40z50EVM-561 eval kit for gauge and the connection board EV2400 directly from TI website.
I followed the instructions for the connection…
Hello Akin,
The reference schematics are founded within the datasheet and evm.
BQ40Z80 schematic: https://www.ti.com/lit/ds/symlink/bq40z80.pdf?ts=1744907310749&ref_url=https%253A%252F%252Fwww.ti.com%252Fproduct%252FBQ40Z80
BQ40z80 EVM: https:/…
Part Number: BQ40Z50-R2 Other Parts Discussed in Thread: BQ40Z50EVM-561 , BQ40Z50 Dear Sir,
I am using BQ40Z50EVM-561 module with four Li batteries. but in in Battery Management studio is not showing voltage of forth battery other three is ok please…
I tried with the evaluation board bq40z50evm-561 with the configuration of 3 cells and 4 cells and i have the same result, the parameter Vbat is not correct.
I am convinced that the problem comes from the BqProduction software.
Hi Nicholas,
If the goal is to use and configure the bq40z50-R1, here are the hardware & software associates I would use:
Hardware: bq40z50EVM and EV2400
https://www.ti.com/tool/BQ40Z50EVM-561
Software: Battery Management Studio
The bq40z50…