Part Number: TIDA-01604 To whom it may concern,
Nice to meet you.
Could you tell me the following information about TIDA-01604?
1. Dimensions and volume without the heatsink
2. Dimensions and volume with the heatsink
Best regards,
Jumpei Niida
Part Number: TIDA-01604 Other Parts Discussed in Thread: PMP40988 , PMP23069 Hello,
While looking into the Digital Power SDK recommended for use with TIDA-01604, I've discovered that the latest version (v4.04) removes support for this example. Is there…
Part Number: TIDA-01604 Hello folks
The 3 interleaved phases are used in the totempole pfc is to reduce the current ripple. if size is the primary concern for the design & not able to accommodate 3 pfc choke, then 6.6kW PFC achievable single pfc choke…
Part Number: TIDA-01604
Hello Experts !
I am designing single phase pfc, How can we select Emi filter values ? Weather it is based on LC filter cutoff frequency ? i currently didt like that. (common mode inductance & Y cap combination for Common mode…
Part Number: TMS320F280049C Other Parts Discussed in Thread: TIDA-01604 , TIDM-HV-1PH-DCAC Hi team,
Customer has some issues
I have recently been working on Totem Pole PFC with DSP280049C and have been referring to your demo TIDA-01604. As a beginner in…
Part Number: TIDA-01604 Hi Team,
PFC section,Totem pole with analog control IC is possible?
Please suggest any analog controller IC is available for Equivalent Digital controller Totem pole implementation.
Thanks
venkatesh B
Part Number: TIDA-01604 Other Parts Discussed in Thread: TIDM-02008
Hi,
We found this PFC Boost 6.6kW eval board in TI website, and we are intending to use it as the proof-of-concept of a product in McLaren Automotive. We need more information about the…
Part Number: TIDA-01604 Hi,
What is the use of FET paralelled full-bridge diode rectifier in the schematic? Is this related to inrush protection?
Thanks CY
Part Number: TIDA-01604 Hello,
As described in the technical document on TIDA-01604, the design uses a non-linear voltage controller to handle the rapid changes in load.
Please refer to "3.2.5.2 Non-Linear Voltage Loop for Transient Reduction" below.…
Part Number: TIDA-010054 Other Parts Discussed in Thread: TIDA-01604 , TIDA-01605 Hi Team,
Why in TIDA-01604 is preferred to use TIDA-01605 instead of TIDA-010054?