  • TI Thinks Resolved

CCS/MSP432P401R: EnergyTrace icon, on Windows using latest CCS with updates, and XDS200 debug probe, greys out when debug is selected.

Expert 1790 points

Replies: 1

Views: 28

Part Number: MSP432P401R

Tool/software: Code Composer Studio

HI,

  I've got a bespoke 432 development board, the code runs (that isn't the issue).

  This is the first time I've enabled EnergyTrace, However the EnergyTrace icon goes from color to greyed out when I select debug.

   I've got an XDS200 series debug probe.

  Any help?

thanks,

  • Guru 146515 points

    Hi,

    XDS200 (TMDSEMU200-U) does not support EnergyTrace. Only XDS110 Debug Probes, which are available either standalone (TMDSEMU110-U) on in the various SimpleLink launchpad boards.

    Regards,

    Rafael