Hi,
1. On the cc256XQFNEM. The debug header is 1.8V however RF1 and RF2 will be at 3.3V.
2. You can add an spp (Serial Port Profile) connection as well to send the sensor data (there is also an LE example). All you would need to do is merge the 2 examples…