TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] The thermal information in the datasheet has changed! What does this mean for me?

    Nikki Dengel
    Nikki Dengel
    FAQ: Logic and Voltage Translation > Power and Thermals >> Current FAQ We have been updating the thermal values in our datasheet, so you may have received a notification about datasheet changes to the thermal values or noticed a datasheet revision about…
    • Answered
    • 7 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can two systems be when using ground-level translator devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Open-Drain Architecture For I2C applications, the allowable distance between systems is primarily limited by total bus capacitance. The I2C specification limits bus capacitance to 400pF for Standard and…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between two grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds is specified in the Electrical Characteristics section in the device datasheet. The table below shows…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a standard level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration when VCCA equals VCCB. If ground shifting is not…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground shifting requires the voltage supplies to be separated and to remain within the recommended operating conditions. In the image below, GNDB shifts by -5V due to parasitic…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Can a negative PWM signal be generated from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative PWM signal can be generated using a ground-level translator if the system includes a negative supply rail. To prevent…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • over 1 year ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    2947 views
    0 replies
    Started over 1 year ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    46143 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Suggested Answer

    SN54LS273: PN JM38510/32501BRA is Out Of Stock/ Anything Similiar? 0

    85 views
    9 replies
    Latest 2 hours ago
    by Nikki Dengel
  • Suggested Answer

    TXS0104E: The output mode for TXS0104E 0

    42 views
    3 replies
    Latest 4 hours ago
    by Zhang Liang
  • Not Answered

    SN74AXCH8T245: Bus Hold behavior when power supply is removed 0

    18 views
    2 replies
    Latest 5 hours ago
    by Derek Payne
  • Suggested Answer

    TXS0206: Level shifter for SDIO 0

    21 views
    3 replies
    Latest 5 hours ago
    by Jack Guan
  • Suggested Answer

    SN74LVC1G14: thermal information update SN74LVC1G14 0

    31 views
    1 reply
    Latest 6 hours ago
    by Rajat Malani
  • Suggested Answer

    TPLD2001: Analog Temp Sensor output 0

    11 views
    2 replies
    Latest 6 hours ago
    by Nikki Dengel
  • Suggested Answer

    SN74LVC06A: capacitive load 0

    23 views
    2 replies
    Latest 6 hours ago
    by Kollin Ewing
  • Suggested Answer

    SN74HC4020: Power Dissipation 0

    11 views
    1 reply
    Latest 6 hours ago
    by Kollin Ewing
  • Suggested Answer

    SN74ALS574B: [EXTERNAL] External Need MSL for TEXAS INSTRUMENTS 0

    26 views
    1 reply
    Latest 7 hours ago
    by Chris Pui
  • Suggested Answer

    74ACT16863: Regarding Your Company's Product 74avc4t245bq-q100 0

    6 views
    1 reply
    Latest 12 hours ago
    by Clemens Ladisch
  • Suggested Answer

    TPS1685: rohs compliance 0

    20 views
    1 reply
    Latest 13 hours ago
    by Amrit Jit
  • Not Answered

    MSPM0G3519: Migration from TMS570LS43x (OSEK-based firmware) to MSPM0G3519-Q1 0

    11 views
    0 replies
    Started 15 hours ago
    by Sneha Dakhare
  • Suggested Answer

    SN74AC00: NRND status for MPN: SN74AC00N 0

    50 views
    1 reply
    Latest 1 day ago
    by Clemens Ladisch
  • Suggested Answer

    SN74AUC1G125: Why is 0.1uF capacitor recommended? 0

    23 views
    1 reply
    Latest 1 day ago
    by Clemens Ladisch
  • Suggested Answer

    SN74LVC8T245: /OE,DIR, & pullup connections, suggestion for application need 0

    142 views
    11 replies
    Latest 1 day ago
    by Joshua Salinas
  • Not Answered

    SN74HC244: As per the received PCN No--20260608001.0 from TEXAS INSTRUMENTS for the part number SN74HC244N. The change is data sheet has been revised to Rev.I by changing 0

    150 views
    7 replies
    Latest 1 day ago
    by Keerthi Grandhi
  • Answered

    TMUX182-SEP: Request for VOH and VOL (Min/Max) Data for TMUX182-SEP 0

    34 views
    3 replies
    Latest 1 day ago
    by Bhakti Jena
  • Not Answered

    SN74AHC1G00: Failures of SN74AHC1G00 marked with 1QP 0

    68 views
    4 replies
    Latest 1 day ago
    by Svetlana Apostolov
>