TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 1 month ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can the two systems be with TXG I2C devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Since the I2C protocol limits the allowable bus capacitance to 400pF (for Standard and Fast Mode) or 550pF (for Fast Mode+), similar requirements will need to be implemented on the TXG8122-Q1. There are…
    • 1 month ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 1 month ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between 2 grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds can be found under the Electrical Characteristics section in the datasheet. Using the TXG1041 datasheet…
    • 1 month ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a regular level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration (VCCA = VCCB). If a user doesn’t need ground shifting…
    • 1 month ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ To use the ground shift capability, voltage supplies need to be separated and fall within the recommended operating conditions. Let’s use the figure above as an example…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Can I generate a negative PWM signal from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative signal can be generated from ground-level translators as long as the user’s system has a negative supply rail. To prevent…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] What are the differences between Ground-Level Translators and Digital Isolators?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground-Level Translators Digital Isolators GNDA to GNDB Difference 80V 3kVrms Galvanic Barrier No Yes GNDA to GNDB Leakage (VCC to GND…
    • 3 months ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    1331 views
    0 replies
    Started 7 months ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    37457 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Not Answered

    SN74HCS151-Q1: CTE 0

    14 views
    0 replies
    Started 6 hours ago
    by Danilo A.
  • Not Answered

    CD4013B: power derating and TI nomenclature 0

    5 views
    0 replies
    Started 11 hours ago
    by Todd Parfitt
  • Suggested Answer

    SN74LVC2G125: Requesting missing parameters for MPN: SN74LVC2G125DCUT 0

    20 views
    1 reply
    Latest 12 hours ago
    by Nikki Dengel
  • Suggested Answer

    SN74HCS86: SN74HCS86PWR related issues 0

    22 views
    1 reply
    Latest 12 hours ago
    by Nikki Dengel
  • Suggested Answer

    SN74AHCU04-Q1: Qualification summary 0

    28 views
    1 reply
    Latest 12 hours ago
    by Albert Xu1
  • Not Answered

    CD4047B: CD4047 Negative-Edge Trigger Monostable Issue 0

    35 views
    2 replies
    Latest 13 hours ago
    by Gerard Jilek
  • Not Answered

    SN5438: SN5438J Thermal Information 0

    20 views
    1 reply
    Latest 15 hours ago
    by Nikki Dengel
  • Suggested Answer

    CD74HC14: CD74HC14 Oscillates on power up 0

    23 views
    1 reply
    Latest 16 hours ago
    by Nikki Dengel
  • Suggested Answer

    SN74LVC2G66: TJ 0

    15 views
    1 reply
    Latest 18 hours ago
    by Arya Hussein
  • Not Answered

    BQ79616-Q1: BQ76PL455A-Q1 PIN71 low temperature test issue 0

    97 views
    6 replies
    Latest 18 hours ago
    by Allen Chu
  • Suggested Answer

    LSF0108-Q1: Marking for LSF0108QWRKSRQ1 0

    68 views
    7 replies
    Latest 1 day ago
    by Jack Guan
  • Suggested Answer

    SN74HC02-Q1: Power consumption of Logic products vs competitors part 0

    36 views
    2 replies
    Latest 1 day ago
    by Lenny Lee
  • Answered

    SN74HCT14-Q1: Request for pin FMA & FMD Data – SN74HCT14-Q1 0

    84 views
    3 replies
    Latest 1 day ago
    by Kavivishnu T
  • Answered

    SN74AHCT1G125-Q1: Request for pin FMA & FMD Data – SN74AHCT1G125-Q1 0

    80 views
    3 replies
    Latest 1 day ago
    by Kavivishnu T
  • Not Answered

    SN74HC165: SN74HC165 data misalignment issue 0

    38 views
    2 replies
    Latest 1 day ago
    by Haoqi Zheng
  • Suggested Answer

    SN74AHCT541: The situation where the back shapes of SN74AHCT541PWR are inconsistent in different batches 0

    44 views
    3 replies
    Latest 1 day ago
    by Albert Xu1
  • Suggested Answer

    SN74AHCT125: Is the recommended drop in replacement in TI cross reference tool is not correct about Cross of Nexperia item 74LVTH125BQ,115 ? 0

    18 views
    1 reply
    Latest 1 day ago
    by Michael Marinello
  • Suggested Answer

    SN74HCS74-Q1: AEC 006 qualification 0

    118 views
    7 replies
    Latest 1 day ago
    by Owen Westfall
>