TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 2 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can the two systems be with TXG I2C devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Since the I2C protocol limits the allowable bus capacitance to 400pF (for Standard and Fast Mode) or 550pF (for Fast Mode+), similar requirements will need to be implemented on the TXG8122-Q1. There are…
    • 2 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 2 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between 2 grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds can be found under the Electrical Characteristics section in the datasheet. Using the TXG1041 datasheet…
    • 2 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a regular level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration (VCCA = VCCB). If a user doesn’t need ground shifting…
    • 2 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • 4 months ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ To use the ground shift capability, voltage supplies need to be separated and fall within the recommended operating conditions. Let’s use the figure above as an example…
    • 4 months ago
    • Logic
    • Logic forum
  • [FAQ] Can I generate a negative PWM signal from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative signal can be generated from ground-level translators as long as the user’s system has a negative supply rail. To prevent…
    • 4 months ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • 4 months ago
    • Logic
    • Logic forum
  • [FAQ] What are the differences between Ground-Level Translators and Digital Isolators?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground-Level Translators Digital Isolators GNDA to GNDB Difference 80V 3kVrms Galvanic Barrier No Yes GNDA to GNDB Leakage (VCC to GND…
    • 4 months ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    1562 views
    0 replies
    Started 8 months ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    39282 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Not Answered

    SN74LVC1G66: Marking for SN74LVC1G66YZPR 0

    6 views
    0 replies
    Started 1 hour ago
    by Suri Chen
  • Not Answered

    SN74LVC1G07: different output voltage with latest DIE revision 0

    42 views
    2 replies
    Latest 1 hour ago
    by Olrik Maier
  • Not Answered

    CD4504B: CD4504B Power Up Glitch 0

    8 views
    0 replies
    Started 2 hours ago
    by Varunesh Kumar
  • Suggested Answer

    TPS53689: Inquiry Regarding TPS53689 Security Features for NIST SP800-193 Compliance 0

    36 views
    2 replies
    Latest 5 hours ago
    by Ryo Sawada
  • Suggested Answer

    SN74LVC1G125: package crack 0

    81 views
    5 replies
    Latest 7 hours ago
    by Chen Alex1
  • Suggested Answer

    TPLD1201: ICS can't simulate counter correctly 0

    66 views
    4 replies
    Latest 7 hours ago
    by user4616635
  • Answered

    TPLD1201: IO7 output 1.15V during startup 0

    118 views
    7 replies
    Latest 7 hours ago
    by user4616635
  • Suggested Answer

    SN74LVC3G34: EOL Notice for SN74LVC3G34DCURE4 0

    25 views
    2 replies
    Latest 8 hours ago
    by Lucas Lim
  • Suggested Answer

    SN74LVCC3245A: Clock signal translation & support query 0

    43 views
    3 replies
    Latest 11 hours ago
    by Joshua Salinas
  • Suggested Answer

    SN74HC14: Inquiry about EOL information 0

    105 views
    3 replies
    Latest 11 hours ago
    by Albert Xu1
  • Suggested Answer

    SN74LV10A: Need to know how to make sure the spec of SN74LV10A 0

    18 views
    1 reply
    Latest 13 hours ago
    by Malcolm Lyn
  • Suggested Answer

    SN54SLC8T245-SEP: Data Rate 0

    85 views
    4 replies
    Latest 13 hours ago
    by Chris Lee
  • Suggested Answer

    SN74LV2T74-EP: what is junc temp for the SN74LV2T74PWREP 0

    19 views
    1 reply
    Latest 13 hours ago
    by Malcolm Lyn
  • Suggested Answer

    SN74LVC1G32: Input voltage of SN74LVC1G32 0

    23 views
    1 reply
    Latest 14 hours ago
    by Malcolm Lyn
  • Suggested Answer

    SN74AC125-Q1: SN74LVC125-Q1 vs SN74AC125-Q1 transition rise/fall rate 0

    32 views
    1 reply
    Latest 14 hours ago
    by Malcolm Lyn
  • Suggested Answer

    SN54LS123: M38510/31401B2A - ACTIVE LOW PINS 0

    29 views
    1 reply
    Latest 14 hours ago
    by Malcolm Lyn
  • Suggested Answer

    TXB0108: Compatibility Question with Memory Intereface 0

    28 views
    2 replies
    Latest 14 hours ago
    by Chris Lee
  • Suggested Answer

    SN74LVC541A: Data sheet Rev.SCAS298M 0

    24 views
    1 reply
    Latest 14 hours ago
    by Malcolm Lyn
>